Fire behaviour of axially loaded high-strength concrete-filled circular high-strength steel tubular columns

被引:3
作者
Du, Tao [1 ]
Liu, Faqi [2 ,3 ]
Yang, Hua [2 ,3 ]
Peng, Kang [1 ]
机构
[1] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
[2] Harbin Inst Technol, Key Lab Struct Dynam Behav & Control, Minist Educ, Harbin 150090, Peoples R China
[3] Harbin Inst Technol, Key Lab Smart Prevent Mitigat Civil Engn Disasters, Minist Ind & Informat Technol, Harbin 150090, Peoples R China
基金
中国国家自然科学基金;
关键词
Fire resistance; High-strength concrete filled high-strength; steel tube; Experiments; FEA; Calculation method; MECHANICAL-PROPERTIES; STRUCTURAL-STEEL; TUBE COLUMNS; RESISTANCE; DESIGN; SQUARE;
D O I
10.1016/j.engstruct.2025.119781
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High-strength concrete-filled high-strength steel tubular (high-strength CFST for short) columns, characterized by the high-strength materials, exhibit fire performance distinct from that of normal-strength concrete-filled steel tubular (normal-strength CFST for short) columns due to the more critical material degradation at high temperatures. However, existing fire research and evaluation methods primarily focus on the normal-strength CFST columns, leaving a gap in understanding the fire behaviour of high-strength CFST columns. To address the deficiency of this area, a series of ISO 834 standard fire tests were conducted on four slender high-strength CFST columns and one slender normal-strength CFST column under axial load. During the experiments, the temperatures and deformations of the specimens were meticulously recorded. The results reveal a significant influence of load ratio on the fire resistance of high-strength CFST columns and the fact that the high-strength CFST column exhibits a shorter fire resistance compared to the normal-strength CFST column under the same load ratio. A finite element (FE) model integrating temperature field and mechanical analysis with the sequentially coupled approach was developed using ABAQUS and validated against the experimental data. Subsequently, the parametric investigation was performed to explore a wider range of high-strength CFST column parameters. A simplified method was proposed to estimate the load capacities of high-strength CFST columns subjected to fire.
引用
收藏
页数:17
相关论文
共 68 条
  • [1] [Anonymous], 2021, ABAQUS CAE 2021, Reference Manual
  • [2] [Anonymous], 2005, Eurocode 3: Design of Steel Structures, Part 1-2: General Rules - Structural Fire Design
  • [3] [Anonymous], 1999, 13407 ISO, P1
  • [4] [Anonymous], 2007, 19931122007 EN
  • [5] [Anonymous], 2022, AISC 360-22
  • [6] [Anonymous], 2019, 123903 BS EN
  • [7] [Anonymous], 2000, ISO 12570
  • [8] [Anonymous], 2017, 512492017 GB
  • [9] [Anonymous], 2014, GB 50936-2014
  • [10] [Anonymous], 2004, EN 1992-1-2