Optimizing Stem Length in Conversion Total Hip Arthroplasty: An Expanded Finite Element Analysis

被引:0
|
作者
Shimasaki, Koshiro [1 ]
Nishino, Tomofumi [1 ]
Yoshizawa, Tomohiro [1 ]
Watanabe, Ryunosuke [1 ]
Hirose, Fumi [1 ]
Yasunaga, Shota [1 ]
Mishima, Hajime [1 ]
机构
[1] Univ Tsukuba, Inst Med, Dept Orthopaed Surg, 1-1-1 Tennodai, Tsukuba 3058575, Japan
关键词
conversion total hip arthroplasty (cTHA); finite element analysis (FEA); stress concentration; periprosthetic fracture; stem length; FAILED INTERNAL-FIXATION; INTERTROCHANTERIC FRACTURE; PERIPROSTHETIC FRACTURES; CORTICAL DEFECTS; FEMORAL-NECK; SALVAGE; FEMUR; COMPLICATIONS; STRESS; BIOMECHANICS;
D O I
10.3390/jcm14041141
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Stress concentration around distal screw-removal holes confers a major risk for periprosthetic fractures following conversion total hip arthroplasty (cTHA) for intertrochanteric femoral fractures. Optimal stem-selection criteria and guidelines for cTHA can improve clinical outcomes. We determined the influence of the cementless stem length on the stress distribution around distal screw-removal holes. Methods: For the finite element analysis, institutional data from preoperative CT scans of contralateral femurs of patients who underwent THA were used. To replicate the post-nail-removal state, we used 3D registration of standard triangulated language data of the intramedullary nail as an unused material to simulate distal screw-removal holes, located 135 mm from the proximal end of the intramedullary nail. Cementless stems of 130, 140, 150, and 160 mm were individually registered using STL data, and cTHA models were constructed accordingly. Using simulations under load conditions representing normal walking and stair climbing, the mean and maximum equivalent stress values around the distal screw-removal holes were calculated. For multiple comparisons, repeated-measures ANOVA with Bonferroni correction was employed. Results: Compared to the 130 mm stem, the 150 mm and 160 mm stems similarly reduced the maximum equivalent stress around the distal screw-removal holes, although the 140 mm stem showed no significant difference with other stems. Conclusions: A >= 150 mm stem length reliably mitigated stress concentration around distal screw-removal holes post-cTHA; it is the optimal choice for balancing effectiveness and risk of complications and may contribute to improved long-term clinical outcomes. This study provides practical evidence for stem selection in cTHA and offers valuable insights for future treatment guidelines.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Musculoskeletal-based finite element analysis of femur after total hip replacement
    Meena, Vijay K.
    Kumar, Mohit
    Pundir, Amit
    Singh, Suman
    Goni, Vijay
    Kalra, Parveen
    Sinha, Ravindra K.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (06) : 553 - 560
  • [32] Finite element analysis of biomechanical effects of total ankle arthroplasty on the foot
    Wang, Yan
    Li, Zengyong
    Wong, Duo Wai-Chi
    Cheng, Cheng-Kung
    Zhang, Ming
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2018, 12 : 55 - 65
  • [33] Conversion total hip arthroplasty following proximal femur fracture: A retrospective analysis
    Anderson, Philip Mark
    Rudert, Maximilian
    Holzapfel, Boris Michael
    Meyer, Julian Stefan
    Weissenberger, Manuel
    Boelch, Sebastian Philipp
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (02) : 507 - 516
  • [34] Importance of polyethylene thickness in total shoulder arthroplasty: A finite element analysis
    Terrier, Alexandre
    Brighenti, Vittoria
    Pioletti, Dominique P.
    Farron, Alain
    CLINICAL BIOMECHANICS, 2012, 27 (05) : 443 - 448
  • [35] STUDY OF FUNCTIONAL OUTCOME OF CONVERSION TOTAL HIP ARTHROPLASTY
    Jose, R. Sahaya
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (92): : 15722 - 15727
  • [36] The assessment of implant shape-dependent failure mechanisms in primary total hip arthroplasty using finite element analysis
    Kazemirad, Siavash
    Yazdi, Mohammad Ali
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2025, 28 (06) : 750 - 763
  • [37] Fixation techniques and stem dimensions in hinged total knee arthroplasty: a finite element study
    El-Zayat, Bilal Farouk
    Heyse, Thomas J.
    Fanciullacci, Nelson
    Labey, Luc
    Fuchs-Winkelmann, Susanne
    Innocenti, Bernardo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (12) : 1741 - 1752
  • [38] Fixation techniques and stem dimensions in hinged total knee arthroplasty: a finite element study
    Bilal Farouk El-Zayat
    Thomas J. Heyse
    Nelson Fanciullacci
    Luc Labey
    Susanne Fuchs-Winkelmann
    Bernardo Innocenti
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 1741 - 1752
  • [39] The accuracy of digital templating: a comparison of short-stem total hip arthroplasty and conventional total hip arthroplasty
    Schmidutz, Florian
    Steinbrueck, Arnd
    Wanke-Jellinek, Lorenz
    Pietschmann, Matthias
    Jansson, Volkmar
    Fottner, Andreas
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1767 - 1772
  • [40] The Lawrence D. Dorr Surgical Techniques & Technologies Award: Conversion Total Hip Arthroplasty: Is it a Primary or Revision Hip Arthroplasty
    Baghoolizadeh, Mahta
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2016, 31 (09) : S16 - S21