Optimizing Stem Length in Conversion Total Hip Arthroplasty: An Expanded Finite Element Analysis

被引:0
|
作者
Shimasaki, Koshiro [1 ]
Nishino, Tomofumi [1 ]
Yoshizawa, Tomohiro [1 ]
Watanabe, Ryunosuke [1 ]
Hirose, Fumi [1 ]
Yasunaga, Shota [1 ]
Mishima, Hajime [1 ]
机构
[1] Univ Tsukuba, Inst Med, Dept Orthopaed Surg, 1-1-1 Tennodai, Tsukuba 3058575, Japan
关键词
conversion total hip arthroplasty (cTHA); finite element analysis (FEA); stress concentration; periprosthetic fracture; stem length; FAILED INTERNAL-FIXATION; INTERTROCHANTERIC FRACTURE; PERIPROSTHETIC FRACTURES; CORTICAL DEFECTS; FEMORAL-NECK; SALVAGE; FEMUR; COMPLICATIONS; STRESS; BIOMECHANICS;
D O I
10.3390/jcm14041141
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Stress concentration around distal screw-removal holes confers a major risk for periprosthetic fractures following conversion total hip arthroplasty (cTHA) for intertrochanteric femoral fractures. Optimal stem-selection criteria and guidelines for cTHA can improve clinical outcomes. We determined the influence of the cementless stem length on the stress distribution around distal screw-removal holes. Methods: For the finite element analysis, institutional data from preoperative CT scans of contralateral femurs of patients who underwent THA were used. To replicate the post-nail-removal state, we used 3D registration of standard triangulated language data of the intramedullary nail as an unused material to simulate distal screw-removal holes, located 135 mm from the proximal end of the intramedullary nail. Cementless stems of 130, 140, 150, and 160 mm were individually registered using STL data, and cTHA models were constructed accordingly. Using simulations under load conditions representing normal walking and stair climbing, the mean and maximum equivalent stress values around the distal screw-removal holes were calculated. For multiple comparisons, repeated-measures ANOVA with Bonferroni correction was employed. Results: Compared to the 130 mm stem, the 150 mm and 160 mm stems similarly reduced the maximum equivalent stress around the distal screw-removal holes, although the 140 mm stem showed no significant difference with other stems. Conclusions: A >= 150 mm stem length reliably mitigated stress concentration around distal screw-removal holes post-cTHA; it is the optimal choice for balancing effectiveness and risk of complications and may contribute to improved long-term clinical outcomes. This study provides practical evidence for stem selection in cTHA and offers valuable insights for future treatment guidelines.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Stress Analysis in Conversion Total Hip Arthroplasty: A Finite Element Analysis on Stem Length and Distal Screw Hole
    Shimasaki, Koshiro
    Nishino, Tomofumi
    Yoshizawa, Tomohiro
    Watanabe, Ryunosuke
    Hirose, Fumi
    Yasunaga, Shota
    Mishima, Hajime
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (01)
  • [2] Total Hip Arthroplasty in Hip Osteoarthritis with Subtrochanteric Localized Periosteal Thickening: Preoperative Planning Using Finite Element Analysis to Determine the Optimal Stem Length
    Shimasaki, Koshiro
    Nishino, Tomofumi
    Yoshizawa, Tomohiro
    Watanabe, Ryunosuke
    Hirose, Fumi
    Yasunaga, Shota
    Mishima, Hajime
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (19)
  • [3] Femoral Stress Changes after Total Hip Arthroplasty with the Ribbed Prosthesis: A Finite Element Analysis
    Luo, Changqi
    Wu, Xiang-Dong
    Wan, Yifei
    Liao, Junyi
    Cheng, Qiang
    Tian, Mian
    Bai, Zhibiao
    Huang, Wei
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [4] A study on finite element analysis methodologies and approaches used for total hip arthroplasty
    Belwanshi, Manish
    Jayaswal, Pratesh
    Aherwar, Amit
    MATERIALS TODAY-PROCEEDINGS, 2022, 56 : 2596 - 2604
  • [5] Bionic reconstruction of tension trabeculae in short-stem hip arthroplasty: a finite element analysis
    Ding, Zhentao
    Wang, Jun
    Wang, Yanhua
    Zhang, Xiaomeng
    Huan, Yong
    Zhang, Dianying
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [6] Primary vs Conversion Total Hip Arthroplasty: A Cost Analysis
    Chin, Garwin
    Wright, David J.
    Snir, Nimrod
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2016, 31 (02) : 362 - 367
  • [7] Total hip arthroplasty by using a cementless ultrashort stem: A subject-specific finite element analysis for a young patient clinical case
    Epasto, Gabriella
    Foti, Albina
    Guglielmino, Eugenio
    Rosa, Michele A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (07) : 757 - 766
  • [8] Biomechanical Investigation of the Impact of Femoral Stem Size on Stress Distribution in Total Hip Arthroplasty: A Finite Element Analysis Study
    Rezaei, Shahabedine
    Rajaeirad, Mohadese
    Kamal, Zeinab
    Gilakjani, Hassan Asadi
    Khorsandi, Mohammad
    2023 30TH NATIONAL AND 8TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2023, : 279 - 283
  • [9] Anatomic grooved stem mitigates strain shielding compared to established total hip arthroplasty stem designs in finite-element models
    Heyland, Mark
    Checa, Sara
    Kendoff, Daniel
    Duda, Georg N.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [10] Conversion Total Hip Arthroplasty A Reason Not to Use Cephalomedullary Nails
    Bercik, Michael J.
    Miller, Adam G.
    Muffly, Matthew
    Parvizi, Javad
    Orozco, Fabio
    Ong, Alvin
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08) : 117 - 121