Multi-objective optimization and performance evaluation of a cooling tower assisted ground source heat pump system under different intermittent control strategies

被引:0
|
作者
Liu, Yifei [1 ,2 ]
Zhang, Guozhu [1 ,2 ]
Wang, Zhongtao [3 ]
Ding, Jiayuan [4 ]
Wang, Hao [3 ]
Cao, Ziming [1 ,2 ]
机构
[1] Southeast Univ, Inst Geotech Engn, Nanjing 211189, Peoples R China
[2] Southeast Univ, Jiangsu Key Lab Low Carbon & Sustainable Geotech E, Nanjing 211189, Peoples R China
[3] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[4] Southeast Univ, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Nanjing 211189, Peoples R China
关键词
Multi-objective optimization; Performance evaluation; Ground source heat pump system; Cooling tower; Intermittent control strategies; THERMAL IMBALANCE; TAGUCHI METHOD; OPTIMAL-DESIGN; EXCHANGERS; ALGORITHM; MODEL;
D O I
10.1016/j.enbuild.2024.115268
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ground source heat pump (GHSP) system is widely utilized currently due to its advantages in economy, environment, and energy aspects. However, different building load demands during heating and cooling seasons cause the difference in heat intakes, leading to the ground thermal imbalance, and will further impact the operating performances of the system. Cooling tower (CT) is employed as an assisting method to alleviate the above problems in cooling-dominated areas. Various CT control strategies have been applied and studied nowadays, including fixed running time (FRT) control strategy, fixed entering fluid temperature (FET) control strategy, and fixed temperature difference (FTD) control strategy. In this study, multi-objective optimization (MOO) method is utilized and an optimizing framework is proposed based on NSGA-II. Concerning the economy, environment, and energy performances of cooling tower assisted ground source heat pump (CT-GSHP) system, operating period cost (OPC), operating period environmental performance (OPEP), and total energy consumption (TEC) are used as objective functions. COMSOL Multiphysics is utilized to establish the numerical model and demonstrate the performances of the system during a 10-year period. One representative set of optimized solutions illustrates that FET method has the best OPC with the value of 43.01 x 106 CNY, FTD method gets the best OPEP value of 2674.44 tCO2, and TEC of FRT is the lowest with the value of 2295.24 MWh. What's more, FRT, FET, and FTD methods keep the coefficient of performance (COP) and energy efficiency ratio (EER) at relatively stable ranges, and decrease the imbalance of ground temperature by 72.64 %, 75.03 %, and 76.98 %, respectively. Results of this research can offer references to the operation and enhance the comprehensive performances of CT-GSHP systems.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Performance and feasibility study of hybrid ground source heat pump system assisted with cooling tower for one office building based on one Shanghai case
    Liu, Zhijian
    Li, Yuanwei
    Xu, Wei
    Yin, Hang
    Gao, Jun
    Jin, Guangya
    Lun, Liyong
    Jin, Guohui
    ENERGY, 2019, 173 : 28 - 37
  • [32] Optimization of thermal performance of a building with ground source heat pump system
    Zogou, Olympia
    Stamatelos, Anastassios
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (11) : 2853 - 2863
  • [33] Multi-objective optimization of a solar assisted heat pump-driven by hybrid PV
    Bellos, Evangelos
    Tzivanidis, Christos
    APPLIED THERMAL ENGINEERING, 2019, 149 : 528 - 535
  • [34] Experimental investigation and control optimization of a ground source heat pump system
    Xia, Lei
    Ma, Zhenjun
    McLauchlan, Craig
    Wang, Shugang
    APPLIED THERMAL ENGINEERING, 2017, 127 : 70 - 80
  • [35] Optimization of a hybrid photovoltaic/thermal-ground source heat pump system using artificial neural networks and multi-objective genetic algorithms
    Andalibi, Ali
    Safarzadeh, Mohammad
    Sobhani, Seyed Mohammad Jafar
    Pasdarshahri, Hadi
    JOURNAL OF BUILDING ENGINEERING, 2025, 103
  • [36] Performance analysis and multi-objective optimization of cooling tower assisted vapor compression-absorption cascaded and hybrid refrigeration systems
    Jain, Vaibhav
    Sharma, Neelam
    Sachdeva, Gulshan
    Kachhwaha, S. S.
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2019, 16 (13) : 1024 - 1045
  • [37] Simulation of Solar Assisted Ground Source Heat Pump System in Different Regions
    Zhou, Qintao
    Dong, Hua
    Zhou, Enze
    Yi, Wei
    PROGRESS IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2012, 354-355 : 798 - 801
  • [38] Energy and exergy analysis of a ground source heat pump system for a public building in Wuhan, China under different control strategies
    Hu, Pingfang
    Hu, Qiushi
    Lin, Yaolin
    Yang, Wei
    Xing, Lu
    ENERGY AND BUILDINGS, 2017, 152 : 301 - 312
  • [39] Experimental investigation and optimization of a ground source heat pump system under different indoor set temperatures
    Zhai, X. Q.
    Wang, X. L.
    Pei, H. T.
    Yang, Y.
    Wang, R. Z.
    APPLIED THERMAL ENGINEERING, 2012, 48 : 105 - 116
  • [40] Designing and optimization of solar assisted ground source heat pump system to supply heating, cooling and hot water demands
    Nouri, Giti
    Noorollahi, Younes
    Yousefi, Hossein
    GEOTHERMICS, 2019, 82 : 212 - 231