Multi-objective optimization and performance evaluation of a cooling tower assisted ground source heat pump system under different intermittent control strategies

被引:0
|
作者
Liu, Yifei [1 ,2 ]
Zhang, Guozhu [1 ,2 ]
Wang, Zhongtao [3 ]
Ding, Jiayuan [4 ]
Wang, Hao [3 ]
Cao, Ziming [1 ,2 ]
机构
[1] Southeast Univ, Inst Geotech Engn, Nanjing 211189, Peoples R China
[2] Southeast Univ, Jiangsu Key Lab Low Carbon & Sustainable Geotech E, Nanjing 211189, Peoples R China
[3] Dalian Univ Technol, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[4] Southeast Univ, Key Lab Concrete & Prestressed Concrete Struct, Minist Educ, Nanjing 211189, Peoples R China
关键词
Multi-objective optimization; Performance evaluation; Ground source heat pump system; Cooling tower; Intermittent control strategies; THERMAL IMBALANCE; TAGUCHI METHOD; OPTIMAL-DESIGN; EXCHANGERS; ALGORITHM; MODEL;
D O I
10.1016/j.enbuild.2024.115268
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ground source heat pump (GHSP) system is widely utilized currently due to its advantages in economy, environment, and energy aspects. However, different building load demands during heating and cooling seasons cause the difference in heat intakes, leading to the ground thermal imbalance, and will further impact the operating performances of the system. Cooling tower (CT) is employed as an assisting method to alleviate the above problems in cooling-dominated areas. Various CT control strategies have been applied and studied nowadays, including fixed running time (FRT) control strategy, fixed entering fluid temperature (FET) control strategy, and fixed temperature difference (FTD) control strategy. In this study, multi-objective optimization (MOO) method is utilized and an optimizing framework is proposed based on NSGA-II. Concerning the economy, environment, and energy performances of cooling tower assisted ground source heat pump (CT-GSHP) system, operating period cost (OPC), operating period environmental performance (OPEP), and total energy consumption (TEC) are used as objective functions. COMSOL Multiphysics is utilized to establish the numerical model and demonstrate the performances of the system during a 10-year period. One representative set of optimized solutions illustrates that FET method has the best OPC with the value of 43.01 x 106 CNY, FTD method gets the best OPEP value of 2674.44 tCO2, and TEC of FRT is the lowest with the value of 2295.24 MWh. What's more, FRT, FET, and FTD methods keep the coefficient of performance (COP) and energy efficiency ratio (EER) at relatively stable ranges, and decrease the imbalance of ground temperature by 72.64 %, 75.03 %, and 76.98 %, respectively. Results of this research can offer references to the operation and enhance the comprehensive performances of CT-GSHP systems.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Research on multi-objective optimization configuration of solar ground source heat pump system using data-driven approach
    Li, Peng
    Cheng, Junyan
    Yang, Yilin
    Yin, Haipeng
    Zang, Ningbo
    ENERGY, 2024, 313
  • [22] Performance research and multi-objective optimization of concentrating photovoltaic/thermal coupled air source heat pump heating system
    Wang, Na
    Chu, Shangling
    Cheng, Chao
    Zhang, Heng
    Chen, Haiping
    Gao, Dan
    ENERGY, 2024, 296
  • [23] An experimental and multi-objective optimization study of a forced draft cooling tower with different fills
    Singh, Kuljeet
    Das, Ranjan
    ENERGY CONVERSION AND MANAGEMENT, 2016, 111 : 417 - 430
  • [24] Heating and cooling performance of a minitype ground source heat pump system
    Zhai, X. Q.
    Cheng, X. W.
    Wang, R. Z.
    APPLIED THERMAL ENGINEERING, 2017, 111 : 1366 - 1370
  • [25] Distributed energy systems: Multi-objective optimization and evaluation under different operational strategies
    Hou, Jianmin
    Wang, Junjie
    Zhou, Ying
    Lu, Xinmei
    JOURNAL OF CLEANER PRODUCTION, 2021, 280
  • [26] Integrated operation of PV assisted ground source heat pump and air source heat pump system: Performance analysis and economic optimization
    Zheng, Zhihang
    Zhou, Jin
    Xu, Feng
    Zhang, Rongpeng
    Deng, Guang
    ENERGY CONVERSION AND MANAGEMENT, 2022, 269
  • [27] Optimization and performance comparison of combined cooling, heating and power/ground source heat pump/photovoltaic/solar thermal system under different load ratio for two operation strategies
    Zeng, Rong
    Zhang, Xiaofeng
    Deng, Yan
    Li, Hongqiang
    Zhang, Guoqiang
    ENERGY CONVERSION AND MANAGEMENT, 2020, 208
  • [28] Performance evaluation and optimization of a novel solar-ground source heat pump system
    Si, Qiang
    Okumiya, Masaya
    Zhang, Xiaosong
    ENERGY AND BUILDINGS, 2014, 70 : 237 - 245
  • [29] Performance analysis and multi-objective optimization of the high-temperature cascade heat pump system
    Wu, Zhangxiang
    Wang, Xiaoyan
    Sha, Li
    Li, Xiaoqiong
    Yang, Xiaochen
    Ma, Xuelian
    Zhang, Yufeng
    ENERGY, 2021, 223
  • [30] Experimental performance analysis of a solar assisted ground source heat pump system under different heating operation modes
    Dai, Lanhua
    Li, Sufen
    Lin DuanMu
    Li, Xiangli
    Shang, Yan
    Dong, Ming
    APPLIED THERMAL ENGINEERING, 2015, 75 : 325 - 333