A non-contact wearable device for monitoring epidermal molecular flux

被引:0
|
作者
Jaeho Shin [1 ]
Joseph Woojin Song [2 ]
Matthew Thomas Flavin [1 ]
Seunghee Cho [3 ]
Shupeng Li [4 ]
Ansen Tan [5 ]
Kyung Rok Pyun [1 ]
Aaron G Huang [6 ]
Huifeng Wang [1 ]
Seongmin Jeong [7 ]
Kenneth E. Madsen [1 ]
Jacob Trueb [3 ]
Mirae Kim [4 ]
Katelynn Nguyen [1 ]
Angela Yang [1 ]
Yaching Hsu [8 ]
Winnie Sung [3 ]
Jiwon Lee [4 ]
Sooyeol Phyo [2 ]
Ji-Hoon Kim [1 ]
Anthony Banks [9 ]
Jan-Kai Chang [1 ]
Amy S. Paller [3 ]
Yonggang Huang [4 ]
Guillermo A. Ameer [1 ]
John A. Rogers [10 ]
机构
[1] Northwestern University,Querrey
[2] Korea Institute of Science and Technology,Simpson Institute for Bioelectronics
[3] Northwestern University,Center for Advanced Molecular Recognition
[4] Northwestern University,Department of Biomedical Engineering
[5] Chan Zuckerberg Biohub Chicago,Center for Advanced Regenerative Engineering
[6] Georgia Institute of Technology,School of Electrical and Computer Engineering
[7] Northwestern University,Department of Mechanical Engineering
[8] Wearifi Inc,Department of Chemistry
[9] University of Illinois at Urbana-Champaign,Department of Dermatology
[10] Northwestern University Feinberg School of Medicine,Center for Climate and Carbon Cycle Research
[11] Korea Institute of Science and Technology,Division of Energy and Environment Technology
[12] Korea Institute of Science and Technology,Department of Materials Science and Engineering
[13] Korea University,Department of KHU
[14] Kyung Hee University,KIST Convergence Science and Technology
[15] Northwestern University,Department of Civil Engineering
[16] Northwestern University,Department of Surgery
[17] Northwestern University,International Institute for Nanotechnology
[18] Northwestern University,Department of Materials Science and Engineering
[19] Northwestern University,Department of Dermatology
[20] Northwestern University,Department of Neurological Surgery
[21] Northwestern University,Department of Chemistry
[22] Northwestern University,Department of Chemical Engineering
[23] Northwestern University,Department of Electrical Engineering and Computer Science
关键词
D O I
10.1038/s41586-025-08825-2
中图分类号
学科分类号
摘要
Existing wearable technologies rely on physical coupling to the body to establish optical1,2, fluidic3,4, thermal5,6 and/or mechanical7,8 measurement interfaces. Here we present a class of wearable device platforms that instead relies on physical decoupling to define an enclosed chamber immediately adjacent to the skin surface. Streams of vapourized molecular substances that pass out of or into the skin alter the properties of the microclimate defined in this chamber in ways that can be precisely quantified using an integrated collection of wireless sensors. A programmable, bistable valve dynamically controls access to the surrounding environment, thereby creating a transient response that can be quantitatively related to the inward and outward fluxes of the targeted species by analysing the time-dependent readings from the sensors. The systems reported here offer unique capabilities in measuring the flux of water vapour, volatile organic compounds and carbon dioxide from various locations on the body, each with distinct relevance to clinical care and/or exposure to hazardous vapours. Studies of healing processes associated with dermal wounds in models of healthy and diabetic mice and of responses in models using infected wounds reveal characteristic flux variations that provide important insights, particularly in scenarios in which the non-contact operation of the devices avoids potential damage to fragile tissues.
引用
收藏
页码:375 / 383
页数:8
相关论文
共 50 条
  • [41] Non-contact under-mattress sleep monitoring
    Walsh, Lorcan
    McLoone, Sean
    JOURNAL OF AMBIENT INTELLIGENCE AND SMART ENVIRONMENTS, 2014, 6 (04) : 385 - 401
  • [42] Condition monitoring of bridges with non-contact testing technologies
    Abu Dabous, Saleh
    Feroz, Sainab
    AUTOMATION IN CONSTRUCTION, 2020, 116
  • [43] Research on the non-contact torque online monitoring system
    Min, H.S.
    Li, Y.R.
    Wang, Z.G.
    Wuhan Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Wuhan University of Science and Technology (Natural Science Edition), 2001, 24 (03):
  • [44] Non-contact damage monitoring by laser AE technique
    Enoki, M
    Nishinoiri, S
    Third International Conference on Experimental Mechanics and Third Conference of the Asian-Committee-on-Experimental-Mechanics, Pts 1and 2, 2005, 5852 : 214 - 219
  • [45] NON-CONTACT OPTOACOUSTIC MONITORING OF FLAME TEMPERATURE PROFILES
    ZAPKA, W
    POKROWSKY, P
    TAM, AC
    OPTICS LETTERS, 1982, 7 (10) : 477 - 479
  • [46] Microphone Array for Non-contact Monitoring of Rolling Bearings
    Kudriashov, Volodymyr
    Ivanov, Vladislav
    Alexiev, Kiril
    Koprinkova-Hristova, Petia
    ADVANCED COMPUTING IN INDUSTRIAL MATHEMATICS, 2017, 681 : 103 - 114
  • [47] THE DEVELOPMENT OF NON-CONTACT 'TOUCHLESS' MONITORING OF RESPIRATORY RATE
    Addison, Paul S.
    Antunes, Andre
    Montgomery, Dean
    ANESTHESIA AND ANALGESIA, 2022, 134 (4S_SUPPL): : 62 - 63
  • [48] REMOTE NON-CONTACT SOLAR CELL SURFACE MONITORING
    Chiou, Richard
    Mauk, Michael
    Davis, Bret
    PROCEEDINGS OF THE ASME/ISCIE INTERNATIONAL SYMPOSIUM ON FLEXIBLE AUTOMATION, ISFA 2012, 2013, : 645 - 652
  • [49] Combining Magnification and Measurement for Non-Contact Cardiac Monitoring
    Nowara, Ewa M.
    McDuff, Daniel
    Veeraraghavan, Ashok
    2021 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, CVPRW 2021, 2021, : 3805 - 3814
  • [50] Non-contact measurement techniques for structural health monitoring
    Ong, W. H.
    Chiu, W. K.
    INTERNATIONAL CONFERENCE ON MATERIALS FOR ADVANCED TECHNOLOGIES (ICMAT2013), SYMPOSIUM W - ADVANCED STRUCTURAL AND FUNCTIONAL MATERIALS FOR PROTECTION, 2014, 75 : 45 - 50