Agreement between Two Devices for Measuring Pupil Diameter in Patients Implanted with Multifocal Intraocular Lenses

被引:1
作者
Fernandez, Joaquin [1 ]
Burguera, Noemi [1 ]
Rocha-de-Lossada, Carlos [1 ,2 ,3 ,4 ]
Rodriguez-Calvo-de-Mora, Marina [1 ,2 ,3 ]
Rodriguez-Vallejo, Manuel [1 ]
机构
[1] VITHAS Almeria Hosp, Dept Ophthalmol Qvis, Almeria 04120, Spain
[2] VITHAS Malaga, Dept Ophthalmol, Malaga 29016, Spain
[3] Hosp Reg Univ Malaga, Dept Ophthalmol, Plaza Hosp Civil S-N, Malaga 29009, Spain
[4] Univ Seville, Dept Cirugia, Area Oftalmol, Doctor Fedriani S-N, Seville 41009, Spain
关键词
pupil diameter; photopic; mesopic; average; multifocal intraocular lenses; VISUAL FUNCTION; EXTENDED DEPTH; SPHERICAL-ABERRATION; CLINICAL-OUTCOMES; IMAGE QUALITY; FOCUS; PERFORMANCE; PUPILLOMETER; ORBSCAN; SIZE;
D O I
10.3390/vision7020040
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The purpose of this study was to evaluate the agreement between three methods for measuring pupil size in patients implanted with multifocal intraocular lenses (MIOLs): Keratograph 5M (K5M), Pentacam AXL Wave (PW), and a simple hand ruler. Sixty-nine subjects implanted with MIOLs and measured at the three-month follow-up visit were included in this retrospective analysis. K5M and PW were used to measure the photopic (PP) and mesopic (MP) pupil sizes, and a hand ruler was used to measure the pupil under environmental light conditions (135 lux). The Bland-Altman method with its limits (LoAs) was used to assess the agreement. The median PP was 2.8, 2.95, and 3 mm for K5M, PW, and the ruler, respectively (p < 0.05). Differences in PP were statistically significant for all paired comparisons (p < 0.0005) except between PW and the ruler (p = 0.44). The LoAs for the difference in PP between K5M and PW was 0.63 mm. The mean difference for MP between K5M and PW was 0.04 mm (p = 0.34) with LoAs of 0.72 mm. MP measured with K5M and PW could be considered interchangeable, although a correction of -0.3 mm (IC95%: -0.23 to -0.39) should be applied to PP measured with PW to attain the K5M mean.
引用
收藏
页数:10
相关论文
共 53 条
  • [1] Alba-Bueno F, 2014, Arch Soc Esp Oftalmol, V89, P397, DOI 10.1016/j.oftal.2014.01.002
  • [2] Visual function after implantation of a diffractive aspheric trifocal intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega Cueto, Luis
    Belda-Salmeron, Lurdes
    Montes-Mico, Robert
    Fernandez-Vega, Luis
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (05) : 405 - 411
  • [3] [Anonymous], 2002, Integrated Assessment of Trade Liberalization and Trade-Related Policies: A Country Study on the Forestry Sector in Tanzania, P1, DOI DOI 10.3403/02609865
  • [4] [Anonymous], 2018, ISO-11979-7:2018
  • [5] Comparison of Anterior Corneal Aberrometry, Keratometry and Pupil Size with Scheimpflug Tomography and Ray Tracing Aberrometer
    Ashena, Zahra
    Gallagher, Sean
    Naveed, Hasan
    Spalton, David J.
    Nanavaty, Mayank A.
    [J]. VISION, 2022, 6 (01)
  • [6] Clinical and Aberrometric Evaluation of a New Monofocal IOL with Intermediate Vision Improvement
    Bova, Alessandro
    Vita, Stefano
    [J]. JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [7] Cardona Genis, 2016, J Optom, V9, P78, DOI 10.1016/j.optom.2015.06.005
  • [9] Image Quality Comparison of Two Multifocal IOLs: Influence of the Pupil
    Carmen Garcia-Domene, Mari
    Felipe, Adelina
    Peris-Martinez, Cristina
    Navea, Amparo
    Artigas, Jose M.
    Pons, Alvaro M.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (04) : 230 - 236
  • [10] Colvard pupillometer measurement of scotopic pupil diameter in emmetropes and myopes
    Chaidaroon, W
    Juwattanasomran, W
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2002, 46 (06) : 640 - 644