Synthesized V7 QRS Amplitude and Oversensing Episodes in Patients With Subcutaneous Implantable Cardioverter-Defibrillators

被引:0
作者
Okajima, Takashi [1 ,2 ]
Ishikawa, Shinji [1 ]
Yanagisawa, Satoshi [2 ,3 ]
Okamoto, Takayuki [1 ]
Uemura, Yusuke [1 ]
Takemoto, Kenji [1 ]
Inden, Yasuya [2 ]
Murohara, Toyoaki [2 ]
Watarai, Masato [1 ]
机构
[1] Anjo Kosei Hosp, Dept Cardiol, Anjo, Japan
[2] Nagoya Univ, Dept Cardiol, Grad Sch Med, Nagoya, Japan
[3] Nagoya Univ, Dept Adv Cardiovasc Therapeut, Grad Sch Med, Nagoya, Japan
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2024年 / 47卷 / 12期
关键词
inappropriate shock therapies; oversensing episodes; QRS amplitude; subcutaneous implantable cardioverter-defibrillator; synthesized 18-lead electrocardiogram; EFFICACY; SAFETY; ORIGIN;
D O I
10.1111/pace.15086
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundPatients with subcutaneous implantable cardioverter-defibrillators (S-ICDs) experience an oversensing episode (OS) more frequently than those with transvenous ICDs. However, no established electrocardiography (ECG) parameters can accurately detect an OS. This study aimed to evaluate the incidence of an OS in real-world clinical practice and the association of synthesized 18-lead ECG (syn18-ECG) parameters with an OS. MethodsWe retrospectively included 21 consecutive patients who underwent S-ICD implantation and collected syn18-ECG parameters. We placed the generator in a deep posterior position and defined an OS as an inappropriate charging episode caused by cardiac or noncardiac signals. A SMART pass filter and two tachyarrhythmia zones were programed. ResultsThe most frequent underlying heart disease was Brugada/J wave syndrome (n = 7). During a median follow-up period of 1188 days, an OS was observed in six patients (28.6%). The QRS amplitude in synthesized V7 lead (synV7) was significantly lower in the OS group than in the non-OS group (0.59 +/- 0.17 vs. 0.91 +/- 0.35 mV, p = 0.019). The optimal cutoff value of synV7 QRS amplitude was 0.61 mV, with a sensitivity of 80.0% and a specificity of 83.7% for predicting an OS. Univariate logistic analysis showed that a synV7 QRS amplitude of <0.61 mV was only associated with an OS (odd ratio, 20.0; 95% confidence interval, 1.66-241.72; p = 0.018). ConclusionsIn patients with S-ICDs, an OS was not a rare complication during long-term follow-up. A low synV7 QRS amplitude was associated with a high OS incidence.
引用
收藏
页码:1565 / 1573
页数:9
相关论文
共 18 条
  • [1] Basu-Ray Indranill, 2017, JACC Clin Electrophysiol, V3, P1475, DOI 10.1016/j.jacep.2017.07.017
  • [2] How the S-ICD (subcutaneous implantable cardiac defibrillator) senses cardiac signals to minimize cardiac over-sensing and maximize rhythm discrimination
    Brisben, Amy
    [J]. JOURNAL OF ELECTROCARDIOLOGY, 2018, 51 (06) : S38 - S43
  • [3] Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator 2-Year Results From a Pooled Analysis of the IDE Study and EFFORTLESS Registry
    Burke, Martin C.
    Gold, Michael R.
    Knight, Bradley P.
    Barr, Craig S.
    Theuns, Dominic A. M. J.
    Boersma, Lucas V. A.
    Knops, Reinoud E.
    Weiss, Raul
    Leon, Angel R.
    Herre, John M.
    Husby, Michael
    Stein, Kenneth M.
    Lambiase, Pier D.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (16) : 1605 - 1615
  • [4] Clinical and electrocardiographic predictors of T wave oversensing in patients with subcutaneous ICD
    El-Chami, Mikhael F.
    Harbieh, Bernard
    Levy, Mathew
    Leon, Angel R.
    Merchant, Faisal M.
    [J]. JOURNAL OF ARRHYTHMIA, 2016, 32 (03) : 181 - 185
  • [5] Primary Results From the Understanding Outcomes With the S-ICD in Primary Prevention Patients With Low Ejection Fraction (UNTOUCHED) Trial
    Gold, Michael R.
    Lambiase, Pier D.
    El-Chami, Mikhael F.
    Knops, Reinoud E.
    Aasbo, Johan D.
    Bongiorni, Maria Grazia
    Russo, Andrea M.
    Deharo, Jean-Claude
    Burke, Martin C.
    Dinerman, Jay
    Barr, Craig S.
    Shaik, Naushad
    Carter, Nathan
    Stoltz, Thomas
    Stein, Kenneth M.
    Brisben, Amy J.
    Boersma, Lucas V. A.
    [J]. CIRCULATION, 2021, 143 (01) : 7 - 17
  • [6] Clinical impact of ECG changes on oversensing of subcutaneous implantable cardioverter-defibrillators
    Hakamata, Takahiro
    Otsuki, Sou
    Izumi, Daisuke
    Sakaguchi, Yuta
    Suzuki, Naomasa
    Ikami, Yasuhiro
    Hasegawa, Yuki
    Yagihara, Nobue
    Iijima, Kenichi
    Chinushi, Masaomi
    Fuse, Koichi
    Inomata, Takayuki
    [J]. HEART RHYTHM, 2022, 19 (10) : 1704 - 1711
  • [7] Heist E Kevin, 2017, JACC Clin Electrophysiol, V3, P405, DOI 10.1016/j.jacep.2016.10.016
  • [8] The QRS morphology pattern in V5R is a novel and simple parameter for differentiating the origin of idiopathic outflow tract ventricular arrhythmias
    Igarashi, Miyako
    Nogami, Akihiko
    Sekiguchi, Yukio
    Kuroki, Kenji
    Yamasaki, Hiro
    Machino, Takeshi
    Yui, Yoshiaki
    Ogawa, Kojiro
    Talib, Ahmed Karim
    Murakoshi, Nobuyuki
    Kuga, Keisuke
    Aonuma, Kazutaka
    [J]. EUROPACE, 2015, 17 (07): : 1107 - 1116
  • [9] Clinical Significance of Synthesized Posterior/Right-Sided Chest Lead Electrocardiograms in Patients with Acute Chest Pain
    Katoh, Takao
    Ueno, Akira
    Tanaka, Keiji
    Suto, Jiro
    Wei, Daming
    [J]. JOURNAL OF NIPPON MEDICAL SCHOOL, 2011, 78 (01) : 22 - 29
  • [10] Surface Electrocardiogram Screening for Subcutaneous Implantable Cardioverter-Defibrillators in Japanese Patients With and Without Brugada Syndrome
    Kawabata, Mihoko
    Goya, Masahiko
    Sasaki, Takeshi
    Maeda, Shingo
    Yagishita, Atsuhiko
    Shirai, Yasuhiro
    Kaneko, Masakazu
    Shiohira, Shinya
    Isobe, Mitsuaki
    Hirao, Kenzo
    [J]. CIRCULATION JOURNAL, 2017, 81 (07) : 981 - 987