Definition of a framework for volumetric modulated arc therapy plan quality assessment with integration of dose-, complexity-, and robustness metrics

被引:0
|
作者
Orovwighose, Tina [1 ,2 ]
Rhein, Bernhard [1 ,2 ,3 ]
Schramm, Oliver [1 ,2 ]
Jaekel, Oliver [1 ,2 ,3 ,4 ]
Batista, Vania [1 ,2 ]
机构
[1] Heidelberg Univ Hosp, Dept Radiat Oncol, Heidelberg, Germany
[2] Heidelberg Inst Radiat Oncol HIRO, Heidelberg, Germany
[3] Heidelberg Univ Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Dept Radiat Oncol, Heidelberg, Germany
[4] German Canc Res Ctr, Dep Med Phys Radiat Oncol, Heidelberg, Germany
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2024年 / 32卷
关键词
Dose metrics; Plan complexity metrics; Plan robustness metrics; Statistical process control; Robustness prediction; STATISTICAL PROCESS-CONTROL; RADIATION-THERAPY; IMRT; RADIOTHERAPY; OPTIMIZATION; INDEX; FRACTIONATION; MARGINS;
D O I
10.1016/j.phro.2024.100685
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Conventionally, the quality of radiotherapy treatment plans is assessed through visual inspection of dose distributions and dose-volume histograms. This study developed a framework to evaluate plan quality using dose, complexity, and robustness metrics. Additionally, a method for predicting plan robustness metrics using dose and complexity metrics was introduced for cases where plan robustness evaluation is unavailable or impractical. Materials and methods: The framework and prediction models were developed and validated using 103-bronchial Volumetric Modulated Arc Therapy (VMAT)-plans. The application of the framework was demonstrated using 25-VMAT-plans. To identify significant metrics for plan evaluation, 122-metrics were analysed and narrowed down using multivariate Spearman correlation. Metric limits were set with Statistical process control (SPC). Robustness metrics were predicted using multivariable or single linear regression models based on dose-and complexity-metrics. Results: Twenty-five-metrics were selected based on the amount and strength of correlations. R95(dose coverage) and HI95/5(homogeneity index) stood out among the dose-metrics, while the complexity-metrics showed similar correlations. Average scenarios dose at 95 % Clinical Target Volume D95mean(CTV) and Errorbar-based Volume- Histograms (EVH) were notable for robustness metrics. Approximately 99 % of evaluated metrics fell within established SPC limits. The prediction model for D95mean(CTV) showed good performance (adjusted R2 = 0.88, mean squared error (MSE) = 3.84 x 10-6), while the model for EVH demonstrated moderate reliability (adjusted R2 = 0.52, MSE = 0.2). No statistically significant differences were found between the predicted (using dose-and complexity-metrics) and calculated robustness metrics (EVH (p-value = 0.9) and D95mean(CTV) (p-value = 1)). Conclusions: The developed framework enables early detection of sub-optimal, complex and non-robust treatment plans. The predictive model can be used when robustness evaluations are impractical.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Plan Robustness Study of Volumetric-Modulated Arc Therapy Vs. Intensity-Modulated Radiation Therapy for Head and Neck Cancer
    Liu, W.
    Patel, S.
    Shen, J.
    Harrington, D.
    Stoker, J.
    Ding, X.
    Hu, Y.
    Wong, W.
    Halyard, M.
    Schild, S.
    Ezzell, G.
    Bues, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3478 - 3478
  • [22] A longitudinal evaluation of improvements in treatment plan quality for lung cancer with volumetric modulated arc therapy
    Xia, Wenlong
    Liu, Zhiqiang
    Yan, Lingling
    Han, Fei
    Hu, Zhihui
    Tian, Yuan
    Cui, Weijie
    Ren, Wenting
    Guo, Chenlei
    Miao, Junjie
    Dai, Jianrong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (06): : 33 - 43
  • [23] Dosimetric sensitivity of leaf width on volumetric modulated arc therapy plan quality: an objective approach
    Murtaza, Ghulam
    Shamshad, Muhammad
    Ahmed, Munir
    Mehmood, Shahid
    Khan, Ehsan Ullah
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (01) : 76 - 85
  • [24] Multidimensional correlation among plan complexity, quality and deliverability parameters for volumetric-modulated arc therapy using canonical correlation analysis
    Shen, Lanxiao
    Chen, Shan
    Zhu, Xiaoyang
    Han, Ce
    Zheng, Xiaomin
    Deng, Zhenxiang
    Zhou, Yongqiang
    Gong, Changfei
    Xie, Congying
    Jin, Xiance
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (02) : 207 - 215
  • [25] Dose delivery uncertainties assessment in the field junction region of craniospinal irradiation with Volumetric Modulated Arc Therapy using a robustness index and experimental dose verification
    Peppa, Vasiliki
    Zoros, Emmanouil
    Alexiou, Antigoni
    Pissakas, George
    Karaiskos, Pantelis
    PLOS ONE, 2024, 19 (11):
  • [26] The Effect of Dose Rate Decrease and Speed Variation on the Delivery Accuracy of a Volumetric Modulated Arc Therapy Plan
    Wang, K.
    Feng, Y.
    Jin, J.
    Cao, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E617 - E618
  • [27] Incorporating plan complexity into the statistical process control of volumetric modulated arc therapy pre-treatment verifications
    Russo, Serenella
    Saez, Jordi
    Esposito, Marco
    Bruschi, Andrea
    Ghirelli, Alessandro
    Pini, Silvia
    Scoccianti, Silvia
    Hernandez, Victor
    MEDICAL PHYSICS, 2024, 51 (06) : 3961 - 3971
  • [28] Quantitative comparison of volumetric modulated arc therapy and intensity modulated radiotherapy plan quality in sino-nasal cancer
    Sankaralingam, Marimuthu
    Glegg, Martin
    Smith, Suzanne
    James, Allan
    Rizwanullah, Mohammed
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (01) : 8 - 13
  • [29] An Analysis of Plan Robustness for Esophageal Tumors: Comparing Volumetric Modulated Arc Therapy Plans and Spot Scanning Proton Planning
    Warren, Samantha
    Partridge, Mike
    Bolsi, Alessandra
    Lomax, Anthony J.
    Hurt, Chris
    Crosby, Thomas
    Hawkins, Maria A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 199 - 207
  • [30] Exploratory study of the association of volumetric modulated arc therapy (VMAT) plan robustness with local failure in head and neck cancer
    Liu, Wei
    Patel, Samir H.
    Harrington, Daniel P.
    Hu, Yanle
    Ding, Xiaoning
    Shen, Jiajian
    Halyard, Michele Y.
    Schild, Steven E.
    Wong, William W.
    Ezzell, Gary E.
    Bues, Martin