Transcatheter Aortic Valve Replacement in Patients With Quadricuspid Aortic Valve: A Case Series and Systematic Review

被引:0
作者
Sheng, Wenjing [1 ,2 ]
Zhou, Dao [1 ,2 ]
Dai, Hanyi [1 ,2 ]
Zheng, Rongrong [1 ,2 ]
Aihemaiti, Ailifeire [1 ,2 ]
Liu, Xianbao [1 ,2 ,3 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 2, Dept Cardiol, Sch Med, Hangzhou, Peoples R China
[2] State Key Lab Transvasc Implantat Devices, Hangzhou 310009, Peoples R China
[3] Zhejiang Univ, Binjiang Inst, Hangzhou 310052, Zhejiang, Peoples R China
关键词
long-term prognosis; quadricuspid aortic valve; technical success; transcatheter aortic valve replacement; CORONARY OBSTRUCTION; IMPLANTATION; STENOSIS; OUTCOMES;
D O I
10.1155/crp/7815279
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Quadricuspid aortic valve (QAV) is a rare congenital cardiac anomaly associated with symptomatic aortic regurgitation (AR) or aortic stenosis (AS). Transcatheter aortic valve replacement (TAVR) for QAV remains uncertain.Methods: We retrospectively reviewed prospectively collected data from patients with QAV undergoing TAVR in our center and conducted a systematic literature review for further investigation.Results: Five patients with QAV were treated with TAVR between April 2016 and December 2023. The median age was 67 years (range: 59-86), and the median Society of Thoracic Surgeons score (STS-score) was 3.750% (range: 0.916%-11.823%). Procedural success was achieved in all cases. The median follow-up period was 3 years (from 30 days to 7 years). Four of the patients exhibited no serious complications, while one experienced delayed coronary obstruction. Our systematic review included 31 cases from 21 publications and our center. The median age of patients was 79 years (range: 57-90), including 18 males. The median STS score was 7.835%. Severe AS was present in 64.5% of the patients and severe AR in 41.9%. The most common QAV subtype was type B (48.4%). Technical success was achieved in 100% of the cases, with two cases reporting coronary obstruction and one required a permanent pacemaker implantation. During a median follow-up period of 1 year (from 30 days to 7 years), one case experienced serious complications of delayed coronary obstruction.Conclusion: The TAVR may be an alternative treatment for patients with QAV, preliminarily demonstrating feasible early and long-term results from current experience. However, extra precautions regarding coronary artery obstruction complications are necessary due to the rarity and anatomical complexity of QAV.
引用
收藏
页数:16
相关论文
共 63 条
[21]  
Ibrahim M., 2018, Quadricuspid Aortic Valve Stenosis: Expanding Our Experience in Transcatheter Aortic Valve Implantation
[22]   Quadricuspid Aortic Valve: A Report of 12 Cases and a Review of the Literature [J].
Jagannath, Anand D. ;
Johri, Amer M. ;
Liberthson, Richard ;
Larobina, Marco ;
Passeri, Jonathan ;
Tighe, Dennis ;
Agnihotri, Arvind K. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (09) :1035-1040
[23]  
Karlsberg D. W., 2012, Clinical Medicine Insights: Cardiology, V6
[24]  
Kendall Michael R, 2023, CASE (Phila), V7, P113, DOI 10.1016/j.case.2022.11.006
[25]   Preventing Coronary Obstruction During Transcatheter Aortic Valve Replacement From Computed Tomography to BASILICA [J].
Lederman, Robert J. ;
Babaliaros, Vasilis C. ;
Rogers, Toby ;
Khan, Jaffar M. ;
Kamioka, Norihiko ;
Dvir, Danny ;
Greenbaum, Adam B. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (13) :1197-1216
[26]   Transcatheter Aortic Valve Replacement in Asia Present Status and Future Perspectives [J].
Lee, Cheol Hyun ;
Inohara, Taku ;
Hayashida, Kentaro ;
Park, Duk-Woo .
JACC-ASIA, 2021, 1 (03) :279-293
[27]  
Liberati A, 2009, PLOS MED, V6, DOI [10.1371/journal.pmed.1000100, 10.7326/0003-4819-151-4-200908180-00136]
[28]   Transcatheter Aortic Valve Replacement in Aortic Regurgitation [J].
Liu, Lulu ;
Chen, Sai ;
Shi, Jun ;
Qin, Chaoyi ;
Guo, Yingqiang .
ANNALS OF THORACIC SURGERY, 2020, 110 (06) :1959-1965
[29]  
Liu X., 2022, Journal of American Heart Association, V11
[30]   Sealing Behavior in Transcatheter Bicuspid and Tricuspid Aortic Valves Replacement Through Patient-Specific Computational Modeling [J].
Liu, Xianbao ;
Fan, Jiaqi ;
Mortier, Peter ;
He, Yuxin ;
Zhu, Qifeng ;
Guo, Yuchao ;
Lin, Xinping ;
Li, Huajun ;
Jiang, Jubo ;
Rocatello, Giorgia ;
Oliveira, Vanda ;
Dezutter, Tim ;
Sondergaard, Lars ;
Wang, Jian'an .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8