Post-fire progressive collapse resistance of beam-column substructures with RBS connections

被引:1
作者
Zhang, Weiwei [1 ]
Xu, Zhijun [1 ]
Xu, Haolong [1 ]
Zhang, Wanpeng [1 ]
Wang, Zongcheng [3 ]
Chen, Yu [1 ,2 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350116, Peoples R China
[2] Fuzhou Univ, Macao & Taiwan Joint Lab Struct Engn, Int & Hong Kong, Fuzhou 350108, Peoples R China
[3] Fujian Construct Engn Grp Co Ltd, Fuzhou 350003, Peoples R China
关键词
Post-fire conditions; Steel frame structure; Reduced beam section (RBS); Progressive collapse; Flange reduced parameters; END-PLATE CONNECTIONS; STEEL FRAMES;
D O I
10.1016/j.jcsr.2024.109137
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel frame structures repaired after fire exposure exhibit markedly different collapse behavior, compared to their performance under ambient conditions, when subjected to extreme loads. This study investigates the progressive collapse resistance of steel frame structures with reduced beam section (RBS) connections in post-fire conditions, using ten beam-column substructures: one tested at room temperature and nine exposed to various fire conditions. Results show that fire exposure shifts the failure from the RBS to the beam-column connection, significantly impairing the RBS's ability to relocate the plastic hinge, especially at higher fire temperatures. Fire temperature significantly affects collapse resistance, especially above 600 degrees C, whereas fire duration has a comparatively smaller influence on deformation capacity, particularly at 800 degrees C. Elevated temperatures weaken tensile catenary action (TCA), with substructures exposed to 800 degrees C for 90 min failing to transition to the TCAdominated stage. Numerical simulations show that for substructures exposed to 400 degrees C and 600 degrees C, collapse resistance increases with greater flange reduction length, while the relationship between collapse resistance and starting reduction distance follows a rise-and-fall pattern. At 800 degrees C, collapse resistance remains relatively consistent across different starting reduction distances, but increasing the reduction length initially enhances and then reduces resistance. Increasing the reduction depth to 30 mm significantly reduces both the flexural and tensile capacities of the RBS region, shifting the failure mode from the beam-column connection to the RBS region.
引用
收藏
页数:18
相关论文
共 46 条
[1]   Progressive collapse resistance of post-fire cellular beam-column substructures with various web-opening shapes [J].
Alshaikh, Ibrahim M. H. ;
Abadel, Aref A. ;
Tuladhar, Rabin ;
Alwathaf, Ahmed Hasan ;
Nehdi, Moncef L. .
STRUCTURES, 2023, 55 :1874-1893
[2]  
[Anonymous], 2017, SEISMIC EVALUATION R
[3]  
[Anonymous], 2000, FEMA-350
[4]  
ASCE, 2003, Minimum Design Loads for Buildings and Other Structures
[5]   Progressive collapse analysis of beam-column substructures considering various reduced beam web sections [J].
Bi, Xianshun ;
Xu, Haohui ;
Luo, Xia ;
Qiao, Huiyun ;
Xie, Jiafu .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 215
[6]   Experimental study on behavior of top-and-seat-angle with double web-angle (TSDW) connections under fire conditions [J].
Cao, Yifan ;
Lu, Yaoliang ;
Jiang, Jian ;
Chen, Wei ;
Ye, Jihong .
THIN-WALLED STRUCTURES, 2024, 194
[7]   Progressive collapse behavior of joints in steel moment frames involving reduced beam section [J].
Chen, Canwen ;
Qiao, Huiyun ;
Wang, Jinpeng ;
Chen, Yu .
ENGINEERING STRUCTURES, 2020, 225
[8]   Experimental study on high-strength Q460 steel extended end-plate connections at elevated temperatures [J].
Chen, Zhihao ;
Wang, Weiyong ;
Wang, Zhiruoyu .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 200
[9]   Pseudo-dynamic testing of a full-scale two-storey steel building with RBS connections [J].
Di Benedetto, Sabatino ;
Francavilla, Antonella Bianca ;
Latour, Massimo ;
Cavallaro, Giovanni Ferrante ;
Piluso, Vincenzo ;
Rizzano, Gianvittorio .
ENGINEERING STRUCTURES, 2020, 212
[10]   Fire resistance behavior of damaged steel portal frame with RBS connections [J].
Erfani, Ali ;
Dehestani, Mehdi .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 182