Efficacy and Safety of Ab-Interno Canaloplasty in Post-Keratoplasty Patients: 3-Year Results

被引:0
|
作者
Redden, Liam D. [1 ]
Riaz, Kamran M. [1 ]
Murphy, David A. [1 ]
Ding, Kai [1 ]
Khaimi, Mahmoud A. [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Dean McGee Eye Inst, Oklahoma City, OK 73104 USA
来源
CLINICAL OPHTHALMOLOGY | 2024年 / 18卷
关键词
ab-interno canaloplasty; keratoplasty; intraocular pressure; glaucoma; AUTOMATED ENDOTHELIAL KERATOPLASTY; RISK-FACTORS; PENETRATING KERATOPLASTY; OCULAR HYPERTENSION; GRAFT-SURVIVAL; GLAUCOMA; MANAGEMENT; TRABECULOTOMY; PHACOEMULSIFICATION; VISCODILATION;
D O I
10.2147/OPTH.S487384
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the effectiveness and safety of ab-interno canaloplasty (ABiC) for managing intraocular pressure (IOP) in patients following keratoplasty over a three-year period. Methods: This retrospective analysis focused on post-keratoplasty patients treated with ABiC with the iTrack microcatheter (Nova Eye Medical, Fremont, CA, USA) at a single institution. The study assessed the procedure's impact on IOP control, graft survival, and reliance on topical hypotensive medications, with additional observation for any postoperative complications. Surgical success criteria included the percentage of eyes with IOP <= 15 mmHg, IOP <= 18 mmHg, >= 20% IOP reduction, medication-free eyes, and eyes with concurrent IOP and medication reductions. Results: ABiC was performed successfully in a cohort of 16 post-keratoplasty (7 penetrating keratoplasty and 9 endothelial keratoplasty (EK)) eyes. Preoperative mean IOP of 25.8 +/- 7.2 mmHg was significantly reduced to 13.4 +/- 2.9 mmHg (p<0.001) at 1 year postoperatively and maintained at 13.1 +/- 3.9 mmHg (p=0.009) at 3 years postoperatively. The mean number of glaucoma medications was 3.5 +/- 1.7 at baseline, 2.8 +/- 1.3 at 1 year (p=0.107), and 2.5 +/- 1.2 at 3 years postoperatively (p=0.088). Eight eyes (66.7%) maintained IOP <= 15 mmHg, and 10 eyes (83.3%) maintained >= 20% IOP reduction at 3 years. The mean IOP and medication reductions from baseline at 3 years were -49.2% and -28.6%, respectively. Graft clarity was preserved in all patients except for one case of late graft failure that necessitated a repeat EK procedure. Post-ABiC complications included transient hyphema in two patients, neither of which led to long-term adverse outcomes. Conclusion: ABiC appears to be an effective and safe surgical intervention for sustained IOP reduction in post-keratoplasty patients. Graft survival trends are encouraging, and there was a low incidence of complications over a three-year follow-up period.
引用
收藏
页码:3567 / 3577
页数:11
相关论文
共 50 条
  • [21] Safety and glycemic control with insulin degludec use in clinical practice: results from a 3-year Japanese post-marketing surveillance study
    Murata, Takashi
    Husemoen, Lise Lotte N.
    Nemoto, Satoko
    Matsuhisa, Munehide
    DIABETOLOGY INTERNATIONAL, 2024, 15 (01) : 76 - 85
  • [22] Myopia Control Efficacy of Spectacle Lenses With Aspherical Lenslets: Results of a 3-Year Follow-Up Study
    Li, Xue
    Huang, Yingying
    Yin, Ziang
    Liu, Chenyao
    Zhang, Siqi
    Yang, Adeline
    Drobe, Bjorn
    Chen, Hao
    Bao, Jinhua
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 253 : 160 - 168
  • [23] Clinical Events in Coronary Heart Disease Patients With an Ejection Fraction of 40% or Less 3-Year Follow-up Results
    Pischke, Claudia R.
    Elliott-Eller, Melanie
    Li, Minmin
    Mendell, Nancy
    Ornish, Dean
    Weidner, Gerdi
    JOURNAL OF CARDIOVASCULAR NURSING, 2010, 25 (05) : E8 - E15
  • [24] Cardiovascular safety and effectiveness of vildagliptin in patients with type 2 diabetes mellitus: a 3-year, large-scale post-marketing surveillance in Japan
    Ishida, Yosuke
    Murayama, Hiroki
    Shinfuku, Yohei
    Taniguchi, Tomoko
    Sasajima, Takayoshi
    Oyama, Naotsugu
    EXPERT OPINION ON DRUG SAFETY, 2020, 19 (05) : 625 - 631
  • [25] Safety and effectiveness of the fluocinolone acetonide intravitreal implant (ILUVIEN): 3-year results from the European IRISS registry study
    Khoramnia, Ramin
    Peto, Tunde
    Koch, Frank
    Taylor, Simon R.
    Castro de Sousa, Joao Paulo
    Hill, Lauren
    Bailey, Clare
    Chakravarthy, Usha
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2023, 107 (10) : 1502 - 1508
  • [26] Deterioration of anterior resin composite restorations in moderate to severe tooth wear patients: 3-year results
    Lima, Veronica P.
    Crins, Luuk A. M. J.
    Opdam, Niek J. M.
    Moraes, Rafael R.
    Bronkhorst, Ewald M.
    Huysmans, Marie-Charlotte D. N. J. M.
    Loomans, Bas A. C.
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (12) : 6925 - 6939
  • [27] Clinical Outcome of Catheter Ablation in Patients With Nonparoxysmal Atrial Fibrillation Results of 3-Year Follow-Up
    Chao, Tze-Fan
    Tsao, Hsuan-Ming
    Lin, Yenn-Jiang
    Tsai, Chin-Feng
    Lin, Wei-Shiang
    Chang, Shih-Lin
    Lo, Li-Wei
    Hu, Yu-Feng
    Tuan, Ta-Chuan
    Suenari, Kazuyoshi
    Li, Cheng-Hung
    Hartono, Beny
    Chang, Hung-Yu
    Ambrose, Kibos
    Wu, Tsu-Juey
    Chen, Shih-Ann
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (03) : 514 - 520
  • [28] Serum ferritin is associated with arterial stiffness in hemodialysis patients: results of a 3-year follow-up study
    Lin, Kao-Chang
    Tsai, Meng-Yi
    Chi, Chun-Ling
    Yu, Lai-King
    Huang, Li-Hsueh
    Chen, Chien-An
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2015, 47 (11) : 1847 - 1853
  • [29] Efficacy and safety of partial splenic embolization for hypersplenism in pre- and post-liver transplant patients: A 16-year comparative analysis
    DuBois, Byron
    Mobley, David
    Chick, Jeffrey F. B.
    Srinivasa, Ravi N.
    Wilcox, Chad
    Weintraub, Joshua
    CLINICAL IMAGING, 2019, 54 : 71 - 77
  • [30] Safety and efficacy of endovenous laser ablation (EVLA) using 1940 nm and radial emitting fiber: 3-year results of a prospective, non-randomized study and comparison with 1470 nm
    Setia, Abhay
    Schmedt, Claus-Georg
    Beisswenger, Anna
    Dikic, Slobodan
    Demhasaj, Sahit
    Setia, Ocean
    Schmitz-Rixen, Thomas
    Sroka, Ronald
    LASERS IN SURGERY AND MEDICINE, 2022, 54 (04) : 511 - 522