Mechano-Lysis in Whole Blood Clots: On How Mechanics Affect Clot Lysis, and How Lysis Affects Clot Mechanics

被引:0
作者
Bechtel, Grace N. [1 ]
Sugerman, Gabriella P. [2 ]
Eades, Tatum [1 ]
Malinowska, Zuzanna [3 ]
Bush, Adam M. [1 ]
Saber, Hamidreza [4 ]
Parekh, Sapun H. [1 ]
Rausch, Manuel K. [1 ,3 ,5 ,6 ,7 ]
机构
[1] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[2] San Jose State Univ, Dept Biomed Engn, San Jose, CA 95192 USA
[3] Univ Texas Austin, Dept Aerosp Engn & Engn Mech, Austin, TX 78712 USA
[4] Univ Texas Austin, Dell Med Sch, Dept Neurol & Neurosurg, Austin, TX 78712 USA
[5] Univ Texas Austin, Dept Mech Engn, Austin, TX 78712 USA
[6] Univ Texas Austin, Oden Inst Computat Engn & Sci, Austin, TX 78712 USA
[7] Univ Texas Austin, Dept Aerosp Engn & Engn Mech, 2617 Wichita St, Austin, TX 78712 USA
基金
美国国家科学基金会;
关键词
chemo-mechanics; fracture toughness; stiffness; thromboembolism; thrombolysis; tissue plasminogen activator; INTRACORONARY THROMBUS; FIBRIN; THROMBOEMBOLISM; EMBOLIZATION; ERYTHROCYTES; THROMBECTOMY; CONTRACTION; DISTAL; RISK;
D O I
10.1002/adhm.202403389
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Thromboembolic diseases are a significant cause of mortality and are clinically treated enzymatically with tissue plasminogen activator (tPA). Interestingly, prior studies in fibrin fibers and fibrin gels have demonstrated that thrombolysis may be mechanically sensitive. This study aims to expand mechano-lytic studies to whole blood clots. Furthermore, this study investigates not only how mechanics impacts lysis but also how lysis impacts mechanics. Therefore, clots made from whole human blood are exposed to tPA while the clots are either stretched or unstretched. After, the resulting degree of clot lysis is measured by weighing the clots and by measuring the concentration of D-dimer in the surrounding bath. Additionally, each clot's mechanical properties are measured. This study finds that mechanical stretch accelerates loss in clot weight but does not impact the lysis rate as measured by D-dimer. Moreover, lysis not only removes clot volume but also reduces the remaining clot's stiffness and toughness. In summary, tPA-induced lysis of whole clot appears mechanically insensitive, but stretch reduces clot weight. Furthermore, results show that thrombolysis weakens clot. This suggests that thrombolysis may increase the risk of secondary embolizations but may also ease clot removal during thrombectomy, for example.
引用
收藏
页数:8
相关论文
共 65 条
  • [11] Can thrombus age guide thrombolytic therapy?
    Czaplicki, Christopher
    Albadawi, Hassan
    Partovi, Sasan
    Gandhi, Ripal T.
    Quencer, Keith
    Deipolyi, Amy R.
    Oklu, Rahmi
    [J]. CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2017, 7 : S186 - S196
  • [12] Measuring the effect of thrombosis, thrombus maturation and thrombolysis on clot mechanical properties in an in-vitro model
    Dwivedi, Anushree
    Glynn, Aoife
    Johnson, Sarah
    Duffy, Sharon
    Fereidoonnezhad, Behrooz
    McGarry, Patrick
    Gilvarry, Michael
    McCarthy, Ray
    [J]. JOURNAL OF BIOMECHANICS, 2021, 129
  • [13] Elnager A., 2014, CLIN ADV HEMATOL, V2014, P1
  • [14] A new constitutive model for permanent deformation of blood clots with application to simulation of aspiration thrombectomy
    Fereidoonnezhad, Behrooz
    McGarry, Patrick
    [J]. JOURNAL OF BIOMECHANICS, 2022, 130
  • [15] Blood clot fracture properties are dependent on red blood cell and fibrin content
    Fereidoonnezhad, Behrooz
    Dwivedi, Anushree
    Johnson, Sarah
    McCarthy, Ray
    McGarry, Patrick
    [J]. ACTA BIOMATERIALIA, 2021, 127 : 213 - 228
  • [16] Fluid Mechanics of Blood Clot Formation
    Fogelson, Aaron L.
    Neeves, Keith B.
    [J]. ANNUAL REVIEW OF FLUID MECHANICS, VOL 47, 2015, 47 : 377 - 403
  • [17] Blood clot behaves as a poro-visco-elastic material
    Ghezelbash, Farshid
    Liu, Shiyu
    Shirazi-Adl, Aboulfazl
    Li, Jianyu
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 128
  • [18] Gltekin O., 2024, WHAT MAKES BLOOD CLO
  • [19] Biophysical Mechanisms Mediating Fibrin Fiber Lysis
    Hudson, Nathan E.
    [J]. BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [20] Thrombus Composition and Efficacy of Thrombolysis and Thrombectomy in Acute Ischemic Stroke
    Jolugbo, Precious
    Ariens, Robert A. S.
    [J]. STROKE, 2021, 52 (03) : 1131 - 1142