Development of skin corrosion and irritation test methods employing ex vivo porcine skin model

被引:0
作者
Hong, Jeong-hyun [1 ,2 ,3 ]
Lim, Kyung-Min [1 ,2 ,3 ]
机构
[1] Ewha Womans Univ, Coll Pharm, 52 Ewhayeodae gil, Seoul 03760, South Korea
[2] Ewha Womans Univ, Grad Sch Pharmaceut Sci, Seoul 03760, South Korea
[3] Ewha Womans Univ, Grad Program Innovat Biomat Convergence, Seoul 03760, South Korea
基金
新加坡国家研究基金会;
关键词
Skin corrosion; Skin irritation; Porcine skin; Ex vivo; Alternative test; HUMAN EPIDERMIS MODEL; IN-VITRO; EAR SKIN; PIG;
D O I
10.1016/j.tiv.2025.106055
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Skin corrosion and irritation are key local toxicological responses of the skin to chemical exposure. Conventional in vivo methods have limitations such as species difference, ethical concern, and reproducibility issue, necessitating the development of reliable alternatives. We developed skin corrosion (SCT) and irritation test (SIT) methods using ex vivo porcine ear skin based on cell viability and skin barrier disruption. Test chemicals were treated on ex vivo porcine ear skin for 3 min and 60 min (SCT) or 60 min only (SIT). After 40 +/- 2 h postincubation, cell viability assay with CCK-8, and skin barrier test with FITC-dextran penetration were conducted. To evaluate the predictive capacity of the method, 38 reference chemicals (20 corrosives, 8 irritants and 10 no category chemicals) were tested. SCT achieved 96.7 % (29/30) accuracy in identifying corrosives, meeting the performance standards of OECD TG 431 In Vitro Skin Corrosion: Reconstructed Human Epidermis test. The accuracy for subcategorizing corrosive substances into categories 1 A (<25 % at 3 min) and 1B/1C (>= 25 % at 3 min, <25 % at 60 min) was 83.3 % (25/30). The accuracy of SIT identifying non-irritant (>= 50 % at 60 min) was 83.3 % (15/18). FITC-dextran penetration assay showed a similar accuracy, highlighting its value as an alternative endpoint to identify irritants. Collectively, this study demonstrated that the ex vivo porcine skin model may offer a cost-effective, and reliable alternative for skin hazard testing.
引用
收藏
页数:9
相关论文
共 43 条
[1]   An integrated testing strategy for in vitro skin corrosion and irritation assessment using SkinEthic™ Reconstructed Human Epidermis [J].
Alepee, Nathalie ;
Grandidier, Marie-Helene ;
Tornier, Carine ;
Cotovio, Jose .
TOXICOLOGY IN VITRO, 2015, 29 (07) :1779-1792
[2]  
[Anonymous], 2013, Test No. 430: In Vitro Skin Corrosion: Transcutaneous Electrical Resistance Test Method (TER)
[3]  
[Anonymous], 2015, OECD guideline for the testing of chemicals 404: Acute Dermal Irritation/Corrosion
[4]  
[Anonymous], 2023, Globally Harmonized System of Classification and Labelling of Chemicals (GHS), V10th, DOI DOI 10.18356/9789210019071
[5]  
Basketter David, 2012, Interdiscip Toxicol, V5, P98, DOI 10.2478/v10102-012-0017-2
[6]   Identification of cornifelin and early growth response-1 gene as novel biomarkers for in vitro eye irritation using a 3D reconstructed human cornea model MCTT HCE™ [J].
Choi, Seunghye ;
Lee, Miri ;
Lee, Su-Hyon ;
Jung, Haeng-Sun ;
Kim, Seol-Yeong ;
Chung, Tae-Young ;
Choe, Tae-boo ;
Chun, Young-Jin ;
Lim, Kyung-Min .
ARCHIVES OF TOXICOLOGY, 2015, 89 (09) :1589-1598
[7]  
Del Rosso James Q, 2011, J Clin Aesthet Dermatol, V4, P22
[8]   PIG EAR SKIN AS AN INVITRO MODEL FOR HUMAN SKIN PERMEABILITY [J].
DICK, IP ;
SCOTT, RC .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1992, 44 (08) :640-645
[9]  
European Chemicals Agency (ECHA), 2025, C&L Inventory
[10]  
Flint Silva T., 2024, Cutan. Ocul. Toxicol., V1, P21