Is Robotic-Assisted Unicompartmental Knee Arthroplasty Compared to Manual Unicompartmental Knee Arthroplasty Associated With Decreased Revision Rates? An Updated Matched Cohort Analysis

被引:0
作者
Guild, George [1 ,2 ]
Schwab, Joseph [1 ,2 ]
Ross, Bailey J. [3 ]
Mcconnell, Mary Jane [4 ]
Naja, Farideh [1 ,2 ]
Bradbury, Thomas L. [1 ,2 ]
机构
[1] Total Joint Specialists LLC, Adv Ctr Joint Surg, Cumming, GA USA
[2] Northside Hosp Forsyth, Cumming, GA USA
[3] Emory Univ, Sch Med, Dept Orthopaed Surg, Atlanta, GA USA
[4] Univ Alabama Birmingham, Heersink Sch Med, Birmingham, AL USA
来源
ARTHROPLASTY TODAY | 2025年 / 32卷
关键词
Partial knee; Robotic-assisted; Unicompartmental knee arthroplasty; PATIENT SATISFACTION; COST-EFFECTIVENESS; UNICONDYLAR; ACCURACY; COMPLICATIONS; SURVIVORSHIP; OUTCOMES; JOINT;
D O I
10.1016/j.artd.2025.101652
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Despite increased utilization of robotic assistance during unicompartmental knee arthroplasty (UKA), its impact on postoperative outcomes remains unclear. This study aimed to compare rates of postoperative revision and complications among patients undergoing robotic-assisted UKA (RA-UKA) versus manual UKA. Methods: A retrospective matched cohort study was performed. Trends analysis of the annual proportion of RA-UKA between 2010 and 2021 was performed, and RA-UKA patients (n = 3976) were matched 1:3 with manual UKA patients (n = 11,766) across age, sex, Elixhauser Comorbidity Index, and comorbidities. Rates of 2-year prosthesis-related complications were compared between the matched cohorts using multivariable logistic regression. Results: The annual proportion of UKA procedures performed with robotic assistance trended significantly upward (1.51% to 5.19%, P < .001). Within 2 years postoperatively, the RA-UKA cohort exhibited significantly lower rates of aseptic revision (1.84% vs 2.37%; odds ratio: 0.76; P = .040) and aseptic loosening (0.13% vs 0.42%; odds ratio: 0.32; P = .010). Total cost for the index UKA was significantly higher for the RA-UKA cohort ($10,321 vs $7,366; P < .001). Conclusions: There has been a marked increase in utilization of RA-UKA. Compared to matched manual UKA, RA-UKA had lower rates of revision and aseptic loosening at 2-year follow-up, but at a higher total cost for the index procedure. Further research exploring the use of robotics in UKA with attention to patient outcomes and cost is crucial for defining its evolving role in orthopaedic surgery. (c) 2025 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页数:9
相关论文
共 40 条
  • [1] [Anonymous], 2022, medicare-fee-service-supplemental-improper-payment-data
  • [2] Improved implant position and lower revision rate with robotic-assisted unicompartmental knee arthroplasty
    Batailler, Cecile
    White, Nathan
    Ranaldi, Filippo Maria
    Neyret, Philippe
    Servien, Elvire
    Lustig, Sebastien
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) : 1232 - 1240
  • [3] Ten-Year Survivorship and Patient Satisfaction Following Robotic-Arm-Assisted Medial Unicompartmental Knee Arthroplasty A Prospective Multicenter Study
    Bayoumi, Tarik
    Kleeblad, Laura J.
    Borus, Todd A.
    Coon, Thomas M.
    Dounchis, Jon
    Nguyen, Joseph T.
    Pearle, Andrew D.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2023, 105 (12) : 933 - 942
  • [4] Improved Accuracy of Component Positioning with Robotic-Assisted Unicompartmental Knee Arthroplasty
    Bell, Stuart W.
    Anthony, Iain
    Jones, Bryn
    MacLean, Angus
    Rowe, Philip
    Blyth, Mark
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (08) : 627 - 635
  • [5] An Experienced Surgeon Can Meet or Exceed Robotic Accuracy in Manual Unicompartmental Knee Arthroplasty
    Bush, Ashleigh N.
    Ziemba-Davis, Mary
    Deckard, Evan R.
    Meneghini, R. Michael
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (16) : 1479 - 1484
  • [6] Unicompartmental knee arthroplasty: Is robotic technology more accurate than conventional technique?
    Citak, Mustafa
    Suero, Eduardo M.
    Citak, Musa
    Dunbar, Nicholas J.
    Branch, Sharon H.
    Conditt, Michael A.
    Banks, Scott A.
    Pearle, Andrew D.
    [J]. KNEE, 2013, 20 (04) : 268 - 271
  • [7] Incidence and Trends of High Tibial Osteotomy and Unicompartmental Knee Arthroplasty Over the Past Decade: A Lost Art
    Collins, Lacee K.
    Waters, Timothy L.
    Cole, Matthew W.
    Wang, Cindy X.
    Pontius, Uwe R.
    Sommi, Corrine
    Sherman, William F.
    [J]. ARTHROPLASTY TODAY, 2023, 20
  • [8] Revision Analysis of Robotic Arm-Assisted and Manual Unicompartmental Knee Arthroplasty
    Cool, Christina L.
    Needham, Keith A.
    Khlopas, Anton
    Mont, Michael A.
    [J]. JOURNAL OF ARTHROPLASTY, 2019, 34 (05) : 926 - 931
  • [9] Unicompartmental knee arthroplasty has higher revisions than total knee arthroplasty at long term follow-up: a registry study on 6453 prostheses
    Di Martino, A.
    Bordini, B.
    Barile, F.
    Ancarani, C.
    Digennaro, V.
    Faldini, C.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (10) : 3323 - 3329
  • [10] Shorter Hospital Stay and Lower 30-Day Readmission After Unicondylar Knee Arthroplasty Compared to Total Knee Arthroplasty
    Drager, Justin
    Hart, Adam
    Abou Khalil, Jad
    Zukor, David J.
    Bergeron, Stephane G.
    Antoniou, John
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (02) : 356 - 361