Discrepancies in Magnetic Resonance- and Computed Tomography-Based Femoral Version Measurements Despite Strong Correlations

被引:2
|
作者
Zhang, Siqi [1 ,2 ,3 ]
Liu, Ke [4 ]
Gao, Guanying [1 ,2 ,3 ]
Lang, Ning [4 ]
Xu, Yan [1 ,2 ,3 ]
机构
[1] Peking Univ, Peking Univ Third Hosp, Inst Sports Med, Dept Sports Med, 49 North Garden Rd, Beijing, Peoples R China
[2] Beijing Key Lab Sports Injuries, Beijing, Peoples R China
[3] Minist Educ, Engn Res Ctr Sports Trauma Treatment Technol & Dev, Beijing, Peoples R China
[4] Peking Univ Third Hosp, Dept Radiol, Beijing, Peoples R China
关键词
HIP ARTHROSCOPY; FEMOROACETABULAR IMPINGEMENT; ACETABULAR VERSION; ANTEVERSION; OUTCOMES; CT; ANTETORSION; CHILDREN; ANGLE; NECK;
D O I
10.1016/j.arthro.2023.12.025
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To determine the correlation and classification consistency of femoral version measurements between magnetic resonance (MR) and computed tomography (CT) using 4 commonly used measurement methods. Methods: A retrospective study was performed on patients with femoroacetabular impingement (FAI) who received preoperative CT and MR imaging assessment of the surgical hip and ipsilateral distal femur. Femoral version was measured using the Murphy method, the oblique method, the Reiker & aring;s method, and the Lee method. Intra- and inter-rater agreements were calculated. Linear regression and Bland-Altman analysis were performed for measurements using different imaging modalities and measurement methods. Femoral version measurements within the lower quartile, the middle 2 quartiles, and the upper quartile were classified into different groups based on their percentile within the sample population. Classification consistency rates between modalities and methods were calculated and compared. Results: Fifty-three patients (39.4 f 9.1 years; 32 female) were included for analysis. Intra- and inter-rater reliability were high for all modalities and methods (intrarater intraclass correlation coefficient [ICC] range, 0.963-0.993; inter-rater ICC range, 0.871-0.960). MR- and CTbased femoral version measurements showed strong correlations for all methods, with the Lee method demonstrating the strongest association (r = 0.904), while the oblique method exhibited the lowest correlation (r = 0.684) (all P < .001). MR-based measurements were smaller than CT-based measurements, with mean differences ranging from 4.5 degrees to 10.3 degrees. Classification consistency between MR and CT ranged from 51% to 74%, whereas the consistency between different measurement methods ranged from 68% to 85%. Conclusions: While strong correlations were observed between MRand CT-based femoral version measurements, MR-based measurements were significantly smaller than their CT counterparts. Classification consistency between the modalities was moderate to high. Measurements between different methods showed strong correlations with high consistency rates.
引用
收藏
页码:2400 / 2410.e2
页数:13
相关论文
共 50 条
  • [1] Computed tomography-based automated 3D measurement of femoral version: Validation against standard 2D measurements in symptomatic patients
    Schmaranzer, Florian
    Movahhedi, Mohammadreza
    Singh, Mallika
    Kallini, Jennifer R.
    Nanavati, Andreas K.
    Steppacher, Simon D.
    Heimann, Alexander F.
    Kiapour, Ata M.
    Novais, Eduardo N.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2024, 42 (10) : 2237 - 2248
  • [2] Accuracy and Reliability of Computed Tomography and Magnetic Resonance Imaging Compared With True Anatomic Femoral Version
    Beebe, Michael J.
    Wylie, James D.
    Bodine, Bill G.
    Kapron, Ashley L.
    Maak, Travis G.
    Mei-Dan, Omer
    Aoki, Stephen K.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2017, 37 (04) : E265 - E270
  • [3] Correlation of femoral version measurements between computed tomography and magnetic resonance imaging studies in patients presenting with a femoroacetabular impingement-related complaint
    Goldsmith, Campbell
    Cheng, Jennifer
    Mintz, Douglas
    Moley, Peter
    JOURNAL OF HIP PRESERVATION SURGERY, 2023, 9 (04): : 219 - 224
  • [4] Anthropometry of the proximal femur and femoral head in children/adolescents using three-dimensional computed tomography-based measurements
    Darwich, Ali
    Geiselhardt, Christiane
    Bdeir, Mohamad
    Janssen, Sonja
    Schoenberg, Stefan O.
    Gravius, Sascha
    Jawhar, Ahmed
    SURGICAL AND RADIOLOGIC ANATOMY, 2021, 43 (12) : 2009 - 2023
  • [5] Acetabular, Femoral, and Combined Anteversion in a Province in South Korea: Computed Tomography-Based Study
    Cho, Youngho
    Shin, Jaeuk
    Kim, Sangwoo
    CLINICS IN ORTHOPEDIC SURGERY, 2023, 15 (04) : 567 - 573
  • [6] Comparison of Positron Emission Tomography Quantification Using Magnetic Resonance- and Computed Tomography-Based Attenuation Correction in Physiological Tissues and Lesions A Whole-Body Positron Emission Tomography/Magnetic Resonance Study in 66 Patients
    Seith, Ferdinand
    Gatidis, Sergios
    Schmidt, Holger
    Bezrukov, Ilja
    la Fougere, Christian
    Nikolaou, Konstantin
    Pfannenberg, Christina
    Schwenzer, Nina
    INVESTIGATIVE RADIOLOGY, 2016, 51 (01) : 66 - 71
  • [7] Computed tomography-based measurements of normative liver and spleen volumes in children
    Alves, Vinicius de Padua V.
    Dillman, Jonathan R.
    Somasundaram, Elanchezhian
    Taylor, Zachary P.
    Brady, Samuel L.
    Zhang, Bin
    Trout, Andrew T.
    PEDIATRIC RADIOLOGY, 2023, 53 (03) : 378 - 386
  • [8] Point: Principles of Magnetic Resonance Imaging Integration in a Computed Tomography-Based Radiotherapy Workflow
    Brock, Kristy K.
    Dawson, Laura A.
    SEMINARS IN RADIATION ONCOLOGY, 2014, 24 (03) : 169 - 174
  • [9] Femoral Anteversion in the Hip: Comparison of Measurement by Computed Tomography, Magnetic Resonance Imaging, and Physical Examination
    Botser, Itamar B.
    Ozoude, George C.
    Martin, Dorea E.
    Siddiqi, Aheed J.
    Kuppuswami, Sivaraja
    Domb, Benjamin G.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (05) : 619 - 627
  • [10] Comparison of Computed Tomography-Based Artificial Intelligence Modeling and Magnetic Resonance Imaging in Diagnosis of Cholesteatoma
    Eroglu, Orkun
    Eroglu, Yesim
    Yildirim, Muhammed
    Karlidag, Turgut
    Cinar, Ahmet
    Akyigit, Abdulvahap
    Kaygusuz, Irfan
    Yildirim, Hanefi
    Keles, Erol
    Yalcin, Sinasi
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2023, 19 (04) : 342 - 349