Visual and refractive outcomes of trocar-assisted intrascleral three-piece intraocular lens fixation

被引:0
|
作者
Pellegrini, Marco [1 ,2 ,3 ]
Adamo, Ginevra [1 ,2 ]
Nardella, Michele [1 ,2 ]
Sarti, Laura [1 ,2 ]
Talli, Pietro Maria [1 ]
Nasini, Francesco [1 ]
Mura, Marco [1 ,4 ]
机构
[1] Univ Ferrara, St Anna Univ Hosp, Ferrara, Italy
[2] Osped Privati Forli Villa Igea, Dept Ophthalmol, Forli, Italy
[3] Ist Int Ric & Formaz Oftalmol IRFO, Forli, Italy
[4] King Khalid Eye Specialist Hosp, Riyadh, Saudi Arabia
关键词
Intrascleral fixation; scleral fixation; secondary IOL implant; IOL power calculation; SCLERAL FIXATION; ACCURACY;
D O I
10.1177/11206721241304156
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To report the visual and refractive outcomes of trocar-assisted sutureless intrascleral three-piece intraocular lens (IOL) fixation, and to compare the accuracy of different IOL power formulas in this setting. Methods Twenty eyes of 20 patients who underwent trocar-assisted sutureless three-piece IOL scleral fixation were included. Two trocar-cannula systems were placed at 3 and 9 o'clock position creating 2.5 mm scleral tunnels. The haptics of a three-piece IOL were grasped with serrated retinal forceps, externalized through the scleral tunnels and fixed by making a flange. Prediction error (PE) was calculated as the actual postoperative spherical equivalent (SE) refraction minus the SE predicted refraction. The predicted SE was calculated using the Barret Universal II, Emmetropia Verifying Optical (EVO), Hoffer Q, Holladay 1, Holladay II, and SRK/T. Results At 6 months after surgery, corrected distance visual acuity improved from 0.66 +/- 0.36 to 0.17 +/- 0.13 logMAR (p < .001). The lowest median absolute PE was obtained by the Barrett formula (0.73D), followed by the EVO (0.81D), Holladay 1 (0.94D), SRK/T (0.98D), Hoffer Q (1.05D) and Haigis (1.64D) formulas. The highest percentage of eyes within +/- 1.00 D were obtained with the Barrett (60.0%), and EVO (55.0%) formulas. Conclusion Although trocar-assisted intrascleral three-piece IOL fixation yields good visual results, the predictability of refractive outcomes is lower than in standard cataract surgery. All formulas showed a slight tendency towards a hyperopic refractive surprise.
引用
收藏
页数:6
相关论文
共 43 条
  • [1] Refractive outcome and lens power calculation after intrascleral intraocular lens fixation: a comparison of three-piece and one-piece intrascleral fixation technique
    Schranz, Markus
    Reumueller, Adrian
    Kostolna, Klaudia
    Novotny, Caroline
    Schartmueller, Daniel
    Abela-Formanek, Claudette
    EYE AND VISION, 2023, 10 (01)
  • [2] Intrascleral sutureless fixation of three-piece intraocular lens for aphakia management
    Ciloglu, Emine
    Unal, Fikret
    CUKUROVA MEDICAL JOURNAL, 2018, 43 (04): : 951 - 957
  • [3] Refractive outcome of trocar-assisted sutureless scleral fixation with 3-piece intraocular lenses
    Veysel Aykut
    Fehim Esen
    Fatma Sali
    Halit Oguz
    International Ophthalmology, 2021, 41 : 2689 - 2694
  • [4] Refractive outcome of trocar-assisted sutureless scleral fixation with 3-piece intraocular lenses
    Aykut, Veysel
    Esen, Fehim
    Sali, Fatma
    Oguz, Halit
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (08) : 2689 - 2694
  • [5] Trocar-assisted sutureless intrascleral posterior chamber foldable intra-ocular lens fixation
    Y Totan
    R Karadag
    Eye, 2012, 26 : 788 - 791
  • [6] Trocar-assisted sutureless intrascleral posterior chamber foldable intra-ocular lens fixation
    Totan, Y.
    Karadag, R.
    EYE, 2012, 26 (06) : 788 - 791
  • [7] 27-gauge trocar-assisted transconjunctival sutureless intraocular lens scleral fixation
    Diamint, David Vladimir
    Giambruni, Juan Martin
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (03) : NP65 - NP69
  • [8] REFRACTIVE OUTCOMES AFTER SUTURELESS INTRASCLERAL FIXATION OF INTRAOCULAR LENS WITH PARS PLANA VITRECTOMY
    Lee, Ramon
    Govindaraju, Viren
    Farley, Nathan D.
    Abbey, Ashkan M.
    Stem, Maxwell S.
    Shields, Ryan A.
    Wa, Christianne A.
    Williams, George A.
    Faia, Lisa J.
    Hassan, Tarek S.
    Wolfe, Jeremy D.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (04): : 822 - 826
  • [9] Clinical observation of a modified technique for intrascleral fixation of flanged three-piece foldable intraocular lenses through a Hoffman pocket
    Ye, Hongfei
    Wu, Mengxiao
    Sun, Wan
    Lyu, Jiao
    Xu, Yu
    Fei, Ping
    Peng, Jie
    Jin, Haiying
    Zhao, Peiquan
    FRONTIERS IN MEDICINE, 2024, 11
  • [10] One-Year Outcomes of Modified Technique for Scleral Fixation of a Three-Piece Intraocular Lens Without Conjunctival Opening
    Ye, Hongfei
    Zhang, Shiguang
    Mi, Wei
    Fei, Ping
    Zhao, Peiquan
    FRONTIERS IN MEDICINE, 2022, 9