Linking thermal converter AC-DC transfer difference with the AC quantum voltmeter

被引:0
|
作者
Behr, Ralf [1 ]
Budovsky, Ilya [2 ]
Palafox, Luis [1 ]
机构
[1] Phys Tech Bundesanstalt, Bundesallee 100, D-38116 Braunschweig, Germany
[2] Natl Measurement Inst, Bradfield Rd, West Lindfield, NSW 2070, Australia
关键词
Josephson junctions; voltmeter; AC-DC converters; signal synthesis; voltage measurement;
D O I
10.1109/CPEM61406.2024.10646154
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes a general technique of directly linking thermal voltage converters to the revised SI by measuring their AC-DC transfer differences using an AC quantum voltmeter. Preliminary measurements at frequencies from 10 Hz to 3 kHz demonstrate agreement with conventional characterization of better than 1 mu V/V.
引用
收藏
页数:2
相关论文
共 50 条
  • [1] AC-DC Transfer Difference Measurements using a Frequency Output Thermal Converter
    Geronymo, G. M.
    Ihlenfeld, W. G. K.
    Landim, R. P.
    9TH BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2017), 2018, 975
  • [2] AC-DC transfer difference measurement of AC shunts
    Konjevod, Jure
    Dadic, Martin
    Malaric, Roman
    Kunst, Ivica
    2018 FIRST INTERNATIONAL COLLOQUIUM ON SMART GRID METROLOGY (SMAGRIMET), 2018,
  • [3] AC-DC DIFFERENCE RELATIONSHIPS FOR CURRENT SHUNT AND THERMAL CONVERTER COMBINATIONS
    KINARD, JR
    LIPE, TE
    CHILDERS, CB
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (02) : 352 - 355
  • [4] Frequency-dependent component of AC-DC transfer difference of a redesigned calorimetric thermal converter
    Kubiczek, Krzysztof
    Grzenik, Micha l
    Kampik, Marian
    MEASUREMENT, 2024, 226
  • [5] Thermal converter with quartz crystal temperature sensor for AC-DC transfer
    Kampik, M
    Klonz, M
    Skubis, T
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1997, 46 (02) : 387 - 390
  • [6] AC-DC current transfer difference in CMI
    Zachovalova, V. Novakova
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 362 - 363
  • [7] Ac-dc current transfer difference at BEV
    Garcocz, M.
    Heine, G.
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 32 - 33
  • [8] Calorimetric thermal voltage converter as a wideband calculable standard of ac-dc difference
    Filipski, PS
    Clark, RF
    Paulusse, DC
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 167 - 168
  • [9] Evaluation of LF AC-DC difference of coaxially mounted thermal voltage converter
    Filipski, PS
    Clark, RF
    Paulusse, DC
    IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2, 1997, : 720 - 725
  • [10] Calorimetric thermal voltage converter as a wideband calculable standard of AC-DC difference
    Filipski, PS
    Clark, RF
    Paulusse, DC
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 387 - 390