Dosimetric comparison of noncoplanar volumetric modulated arc therapy and helical tomotherapy in whole brain radiotherapy with hippocampus avoidance

被引:0
|
作者
Cheng, Xiao-Long [1 ]
Liu, Ji-Ping [1 ]
Wang, Bin-Bing [1 ]
Sun, Long [1 ]
机构
[1] Zhejiang Canc Hosp, Dept Radiophys, 1 Banshan East Rd, Hangzhou 310022, Peoples R China
关键词
Whole-brain radiotherapy; Hippocampus avoidance; Non-coplanar; Volumetric modulated arc therapy; Helical tomotherapy; RADIATION-THERAPY; LIMBIC CIRCUIT; METASTASES; IMRT; WBRT; IRRADIATION; MEMORY; VMAT; HEAD;
D O I
10.1016/j.jrras.2025.101372
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Whole-brain radiotherapy(WBRT) can alleviate symptoms in patients with brain metastases. However, WBRT may damage the hippocampus.The helical tomotherapy (HT) presents a significant dosimetric advantage in the hippocampus avoidance WBRT(HA-WBRT). How to design linear accelerator radiation therapy plan for HA-WBRT is a challenge for medical physicists. Objective: The aim of this study is to investigate the dosimetric differences between noncoplanar VMAT(NCVMAT) and HT in HA-WBRT, exploring the feasibility of NC-VMAT for HA-WBRT. Methods: Fifteen patients with HA-WBRT were chosen randomly. For each patient, the Monaco TPS was used to design four distinct NC-VMAT plans based on the quantity of non-coplanar arcs (NC-VMATA, NC-VMATB,NC-VMATC,NC-VMATD) for HA-WBRT, totaling 60 plans. The HT TPS was used to generate HT plans, totaling 15 plans.The prescribed dose was 30 Gy in 10 fractions. Treatment plans were established based on the RTOG 0933 criteria.Under the premise that the 95% isodose curve covers the target area, dose-volume histogram(DVH) was applied to evaluate the WB-PTV, CI, HI, Dmax, Dmean, Dmin and doses of OARs in NC-VMAT and HT plans. Paired t-test was performed to compare the differences between each two radiation therapy plans, and p < 0.05 was considered statistically significant. Results: The RTOG0933 criteria could not be satisfied in NC-VMATA with 1 non-coplanar beam. NC-VMATB with 2 non-coplanar beams, the condition Dmax<16 Gy was not satisfied for 8 case in the hippocampus. NC-VMATC with 3 non-coplanar beams, the condition D98% > 25 Gy was not satisfied for 5 case in the WB-PTV. NC-VMATD with 4 non-coplanar beams and HT, all plans complied with the "Per protocol" requirements in the RTOG 0933 standard.We compared NC-VMATD with HT and found that there were no differences in the D98% and D2% of WB-PTV. However, the HT was significantly superior to NC-VMATD in terms of CI, HI, Dmean in HP, Dmax in Lens, Dmean in eyes (p < 0.05). The Dmax, D100% of HP and the dosimetry of other OARs had no significant difference (p > 0.05).In contrast, the average beam on time in NC-VMATD was greater advantage(506s Vs 687s, p < 0.05). NC-VMAT and HT planning templates were devised, which facilitated physicists in rapidly designing high-quality HA-WBRT plans. Conclusion: NC-VMAT proves to be effective in managing HA-WBRT.The plan quality improved along with the increase of non-coplanar arcs. NC-VMAT(one full arc and four noncoplanar partial arcs) with FFF irradiation mode is most recommended plan design pattern. NC-VMAT provides a practical clinical treatment option for HAWBRT based on linear accelerators.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Dosimetric Comparison Between Helical Tomotherapy and Volumetric Modulated Arc Therapy in Patients With Malignant Pleural Mesothelioma
    Muedder, T.
    Sarria, G. R.
    Henkenberens, C.
    Holz, J.
    Garbe, S.
    Roehner, F.
    Stumpf, S.
    Buchstab, T.
    Giordano, F. A.
    Leitzen, C.
    CLINICAL ONCOLOGY, 2022, 34 (03) : 164 - 171
  • [22] SmartArc-based volumetric modulated arc therapy for endometrial cancer: a dosimetric comparison with helical tomotherapy and intensity-modulated radiation therapy
    Yang, Ruijie
    Wang, Junjie
    Xu, Shouping
    Li, Hua
    BMC CANCER, 2013, 13
  • [23] Is IMAT the ultimate evolution of conformal radiotherapy? Dosimetric comparison of helical tomotherapy and volumetric modulated arc therapy for oropharyngeal cancer in a planning study
    Vernat, Stephanie Servagi
    Ali, David
    Puyraveau, Marc
    Viard, Romain
    Lisbona, Albert
    Fenoglietto, Pascal
    Bedos, Ludovic
    Makovicka, Libor
    Giraud, Philippe
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (03): : 280 - 285
  • [24] Dosimetric Comparision of Coplanar versus Noncoplanar Volumetric Modulated Arc Therapy for Treatment of Bilateral Breast Cancers
    Bharati, Avinav
    Rath, Satyajeet
    Khurana, Rohini
    Rastogi, Madhup
    Mandal, Susama R.
    Gandhi, Ajeet Kumar
    Hadi, Rahat
    Srivastava, Anoop K.
    Mishra, Surendra Prasad
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (03) : 252 - 258
  • [25] Dosimetric comparison of vaginal vault brachytherapy vs applicator-guided stereotactic body radiotherapy with volumetric modulated arc therapy and helical tomotherapy for endometrium cancer patients
    Yildirim, Berna Akkus
    Dolek, Yemliha
    Guler, Ozan Cem
    Arslan, Gungor
    Onal, Cem
    MEDICAL DOSIMETRY, 2019, 44 (04) : 332 - 338
  • [26] Radiotherapy for Esophageal Cancer Using Simultaneous Integrated Boost Techniques: Dosimetric Comparison of Helical TomoTherapy, Volumetric-modulated Arc Therapy (RapidArc) and Dynamic Intensity-Modulated Radiotherapy
    Wang, Yao-Ching
    Chen, Shang-Wen
    Chien, Chun-Ru
    Hsieh, Te-Chun
    Yu, Chun-Yen
    Kuo, Yu-Cheng
    Yang, Shih-Neng
    Kao, Chia-Hung
    Liang, Ji-An
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (06) : 485 - 491
  • [27] Dosimetric investigation of whole-brain radiotherapy with helical intensity modulated radiation therapy and volumetric modulated arc therapy for scalp sparing
    Shirata, Ryosuke
    Inoue, Tatsuya
    Sugimoto, Satoru
    Saito, Anneyuko, I
    Omura, Motoko
    Minagawa, Yumiko
    Sasai, Keisuke
    BJR OPEN, 2023, 5 (01):
  • [28] Dosimetric comparison between helical tomotherapy and volumetric modulated arc-therapy for non-anaplastic thyroid cancer treatment
    Khalifa, Jonathan
    Vieillevigne, Laure
    Boyrie, Sabrina
    Ouali, Monia
    Filleron, Thomas
    Rives, Michel
    Laprie, Anne
    RADIATION ONCOLOGY, 2014, 9 : 247
  • [29] Hypofractionated Stereotactic Radiotherapy for Brain Metastases: A Dosimetric and Treatment Efficiency Comparison Between Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy
    Ma, Yidong
    Li, Minghuan
    Yin, Yong
    Kong, Li
    Sun, Xindong
    Lin, Xiutong
    Yu, Jinming
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2010, 9 (05) : 499 - 507
  • [30] Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
    Mizuno, Tomoki
    Tomita, Natsuo
    Takaoka, Taiki
    Tomida, Masashi
    Fukuma, Hiroshi
    Tsuchiya, Takahiro
    Shibamoto, Yuta
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20