Continuous glucose monitoring (Dexcom g6) in people with diabetes after kidney transplantation

被引:0
|
作者
Jakubowska, Zuzanna [1 ]
Malyszko, Jolanta [1 ]
机构
[1] Med Univ Warsaw, Dept Nephrol Dialysis & Internal Dis, Banacha 1A, PL-02097 Warsaw, Poland
关键词
Kidney transplantation; continuous glucose measurement; pressure-induced sensor attenuations; time in range; quality of life; GLYCEMIC CONTROL; VARIABILITY;
D O I
10.1080/0886022X.2024.2413007
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesUse of continuous glucose monitoring-CGM in patients on kidney replacement therapy including kidney transplant recipients, may improve glycemic control and detection of hypoglycemia. However, studies in this population in particular in kidney transplant recipients are very limited.MethodsThe study aimed to evaluate glycemic profiles using the Dexcom G6 CGM system for 30 d a personal smartphone in people with diabetes after kidney transplantation and to assess the impact of monthly use of the CGM system on glycemic control and quality of life in this group.ResultsOver 8 months, 9 people after kidney transplantation were included in the study (7 women, median age 57 years), 8 people with new-onset diabetes after transplantation (NODAT), and 1 person with diabetes mellitus type 1. The time since kidney transplantation in each of the study participants was less than 2 years. In 7 people with NODAT, the time in range was above 70%. In all study participants, hyperglycemia was observed mainly in the afternoon (2-6 pm). In some patients, pressure-induced sensor attenuations (PISAs) were noted. There was no effect of the use of Dexcom G6 on the HbA1c value. There was no impact of the use of the Dexcom G6 system on the perception of overall quality of life, but monthly use had a positive impact on the perception of the quality of health.ConclusionsCGM systems seem to be a promising method for assessing glycemic control in people with diabetes after kidney transplantation. More extensive research is needed to assess safety and usefulness in everyday practice.
引用
收藏
页数:4
相关论文
共 50 条
  • [11] Continuous glucose monitoring in type 1 diabetes
    Mauras, Nelly
    Fox, Larry
    Englert, Kimberly
    Beck, Roy W.
    ENDOCRINE, 2013, 43 (01) : 41 - 50
  • [12] Changes in Accuracy of Continuous Glucose Monitoring Using Dexcom G4 Platinum Over the Course of Moderate Intensity Aerobic Exercise in Type 1 Diabetes
    Larose, Stephanie
    Rabasa-Lhoret, Remi
    Roy-Fleming, Amelie
    Suppere, Corinne
    Tagougui, Semah
    Messier, Virginie
    Taleb, Nadine
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (06) : 364 - 369
  • [13] Continuous glucose monitoring for the prediction of posttransplant diabetes mellitus and impaired glucose tolerance on day 90 after kidney transplantation-A prospective proof-of-concept study
    Eleftheriadis, Georgios
    Naik, Marcel G.
    Osmanodja, Bilgin
    Liefeldt, Lutz
    Choi, Mira
    Halleck, Fabian
    Schrezenmeier, Eva
    Eckardt, Kai-Uwe
    Pigorsch, Mareen
    Tura, Andrea
    Kurnikowski, Amelie
    Hecking, Manfred
    Budde, Klemens
    AMERICAN JOURNAL OF TRANSPLANTATION, 2024, 24 (11) : 2225 - 2234
  • [14] Time in Range and Pregnancy Outcomes in People with Diabetes Using Continuous Glucose Monitoring
    Bartal, Michal Fishel
    Cornthwaite, Joycelyn A. Ashby A.
    Ghafir, Danna
    Ward, Clara
    Ortiz, Gladys
    Louis, Aleaha
    Cornthwaite, John
    Chauhan, Suneet S. P.
    Sibai, Baha M.
    AMERICAN JOURNAL OF PERINATOLOGY, 2023, 40 (05) : 461 - 466
  • [15] An overview and commentary on retrospective, continuous glucose monitoring for the optimisation of care for people with diabetes
    Currie, Craig J.
    Poole, Chris D.
    Papo, Natalie L.
    CURRENT MEDICAL RESEARCH AND OPINION, 2009, 25 (10) : 2389 - 2400
  • [16] Consensus Report on the Use of Continuous Glucose Monitoring in Chronic Kidney Disease and Diabetes
    Rhee, Connie M.
    Gianchandani, Roma Y.
    Kerr, David
    Philis-Tsimikas, Athena
    Kovesdy, Csaba P.
    Stanton, Robert C.
    Drincic, Andjela T.
    Galindo, Rodolfo J.
    Kalantar-Zadeh, Kamyar
    Neumiller, Joshua J.
    de Boer, Ian H.
    Lind, Marcus
    Kim, Sun H.
    Ayers, Alessandra T.
    Ho, Cindy N.
    Aaron, Rachel E.
    Tian, Tiffany
    Klonoff, David C.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2025, 19 (01): : 217 - 245
  • [17] Diabetes: the role of continuous glucose monitoring
    Kluemper, Julianna Rivich
    Smith, Alexandria
    Wobeter, Brooke
    DRUGS IN CONTEXT, 2022, 11
  • [18] Essential Continuous Glucose Monitoring Metrics: The Principal Dimensions of Glycemic Control in Diabetes
    Montaser, Eslam
    Fabris, Chiara
    Kovatchev, Boris
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (11) : 797 - 804
  • [19] Profiles of Intraday Glucose in Type 2 Diabetes and Their Association with Complications: An Analysis of Continuous Glucose Monitoring Data
    Varghese, Jithin Sam
    Ho, Joyce C.
    Anjana, Ranjit Mohan
    Pradeepa, Rajendra
    Patel, Shivani A.
    Jebarani, Saravanan
    Baskar, Viswanathan
    Narayan, K. M. Venkat
    Mohan, Viswanathan
    DIABETES TECHNOLOGY & THERAPEUTICS, 2021, 23 (08) : 555 - 564
  • [20] Use of Continuous Glucose Monitoring in the Assessment and Management of Patients With Diabetes and Chronic Kidney Disease
    Ling, James
    Ng, Jack K. C.
    Chan, Juliana C. N.
    Chow, Elaine
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13