Performance of UF-5000 in rapidly screening out urinary tract infection, predicting Gram-negative bacteria infection

被引:1
作者
Lu, Wei [1 ]
Li, Zhaoxing [1 ]
Zhang, Tong [1 ]
Li, Yan [1 ]
Zhu, Huange [1 ]
Zhao, Ya [1 ]
Lei, Ke [1 ]
Guo, Zhi [1 ]
Zhang, Jing [1 ]
Guo, Juan [1 ]
Zhang, Lei [1 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 2, Dept Lab, Xian, Peoples R China
关键词
urinary tract infections; UF-5000; urine analysis; urine culture; B_FSC; B_FLH; SYSMEX UF-1000I; FLOW-CYTOMETRY; DIAGNOSIS; ANALYZER; RULE;
D O I
10.1128/spectrum.00301-24
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Urine culture is the gold standard for identifying microorganisms in urine. However, the process is time-consuming and usually takes days to get the results, which impedes timely treatment. This study aimed to evaluate the performance of UF-5000 in excluding bacterial urinary tract infection (UTI) and detecting the presence of Gram-negative bacteria. A total of 1,522 urine specimens were subjected to routine urine analysis and culture. Bacteria, white blood cell counts, and UF-5000 bacteria information flags were compared with urine culture. Bacteria forward scatter (B_FSC), and bacteria fluorescent light intensity (B_FLH) parameters were assessed to determine the optimal angle for discriminating bacterial growth patterns, which was verified in the validation cohort. The optimal cut-off values were 42.2/mu L and 100.2/mu L to rule out UTI for bacteria at >= 10(4) CFU/mL and >= 10(5) CFU/mL, respectively. The agreement of UF-5000 bacterial classification and urine culture was fair (Kappa = 0.227). Regarding the discrimination of bacterial groups, "Gram Neg?" was associated with a specificity of 94.0% and a positive predictive value of 87.2% in the detection of Gram-negative bacteria. By estimating the B_FSC and B_FLH parameters, the best angle was 28 degrees for distinguishing Gram-negative and Gram-positive bacteria. Among the 136 urine specimens with the low angle pattern (<28 degrees) in the validation cohort, 127 specimens were confirmed to contain Gram-negative bacteria. The UF-5000 analyzer is a suitable and rapid tool to exclude negative urine specimens, and bacterial information flags for Gram-negative bacteria could be trusted by clinicians. IMPORTANCE The strength of our study relied on being the first study assessing the bacteria forward scatter (B_FSC) and bacteria fluorescent light intensity (B_FLH) research parameters with a UF-5000 urine analyzer and establishing the best angle for distinguishing Gram-negative and Gram-positive bacteria. When the bacterial scatter plot angle is less than 28 degrees, the possibility of Gram-negative bacterial infection is more than 80%. Meanwhile, we find that UF-5000 bacterial information flags have a significant advantage in detecting Gram-negative bacteria with a specificity of over 90% and a positive predictive value of over 80%.
引用
收藏
页数:9
相关论文
共 29 条
[1]   Evaluation of the sysmex UF-5000 fluorescence flow cytometer as a screening platform for ruling out urinary tract infections in elderly patients presenting at the Emergency Department [J].
Alenkaer, Lasse Krogh ;
Pedersen, Lise ;
Szecsi, Pal Bela ;
Bjerrum, Poul Jannik .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2021, 81 (05) :379-384
[2]  
Asutake YY., 2013, SYSMEX J INT, V23
[3]   Screening for Urinary Tract Infection with the Sysmex UF-1000i Urine Flow Cytometer [J].
Broeren, Maarten A. C. ;
Bahceci, Semiha ;
Vader, Huib L. ;
Arents, Niek L. A. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (03) :1025-1029
[4]   Combination of UC-3500 and UF-5000 as a quick and effective method to exclude bacterial urinary tract infection [J].
Chen, Yabin ;
Zhang, Zhishan ;
Diao, Yanjun ;
Wang, Wanni ;
Zhu, Yan ;
Li, Jiaming ;
Wang, Gangqiang ;
Zhao, Yuan ;
Lin, Zhenzhong ;
Wu, Yibo ;
Jing, Jing .
JOURNAL OF INFECTION AND CHEMOTHERAPY, 2023, 29 (07) :667-672
[5]   Comparison of Laboratory Diagnosis of Urinary Tract Infections Based on Leukocyte and Bacterial Parameters Using Standardized Microscopic and Flow Cytometry Methods [J].
Christy, Priskila ;
Sidjabat, Hanna Evelina ;
Toruan, Anggia Augustasia Lumban ;
Moses, Emmanuel Jairaj ;
Yussof, Narazah Mohd ;
Puspitasari, Yessy ;
Fuadi, Muhammad Robiul ;
Marpaung, Ferdy Royland .
INTERNATIONAL JOURNAL OF NEPHROLOGY, 2022, 2022
[6]   Evaluation of the new Sysmex OF-5000 fluorescence flow cytometry analyser for ruling out bacterial urinary tract infection and for prediction of Gram negative bacteria in urine cultures [J].
De Rosa, Rita ;
Grosso, Shamanta ;
Lorenzi, Giada ;
Bruschetta, Graziano ;
Camporese, Alessandro .
CLINICA CHIMICA ACTA, 2018, 484 :171-178
[7]   Evaluation of the Sysmex UF1000i flow cytometer for ruling out bacterial urinary tract infection [J].
De Rosa, Rita ;
Grosso, Shamanta ;
Bruschetta, Graziano ;
Avolio, Manuela ;
Stano, Paola ;
Modolo, Maria Luisa ;
Camporese, Alessandro .
CLINICA CHIMICA ACTA, 2010, 411 (15-16) :1137-1142
[8]   Evaluation and Management of Urinary Tract Infection in the Emergency Department [J].
Dubbs, Sarah B. ;
Sommerkamp, Sarah K. .
EMERGENCY MEDICINE CLINICS OF NORTH AMERICA, 2019, 37 (04) :707-+
[9]   Comparison of the reliability of Gram-negative and Gram-positive flags of the Sysmex UF-5000 with manual Gram stain and urine culture results [J].
Enko, Dietmar ;
Stelzer, Ingeborg ;
Boeckl, Michael ;
Schnedl, Wolfgang J. ;
Meinitzer, Andreas ;
Herrmann, Markus ;
Toetsch, Martin ;
Gehrer, Michael .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (03) :619-624
[10]   Clinical Presentations and Epidemiology of Urinary Tract Infections [J].
Geerlings, Suzanne E. .
MICROBIOLOGY SPECTRUM, 2016, 4 (05)