Reproducibility of 3D thoracic aortic displacement from 3D cine balanced SSFP at 3T without contrast enhancement

被引:0
|
作者
Merton, Renske [1 ,2 ]
Bosshardt, Daan [1 ,2 ]
Strijkers, Gustav J. [2 ,3 ,4 ]
Nederveen, Aart J. [1 ,2 ,4 ]
Schrauben, Eric M. [1 ,2 ]
van Ooij, Pim [1 ,2 ,4 ]
机构
[1] Univ Amsterdam, Radiol & Nucl Med, Amsterdam UMC Locat, Amsterdam, Netherlands
[2] Amsterdam Cardiovasc Sci, Amsterdam, Netherlands
[3] Univ Amsterdam, Biomed Phys & Engn, Amsterdam UMC Locat, Amsterdam, Netherlands
[4] Amsterdam Movement Sci, Amsterdam, Netherlands
关键词
3; T; 3D cine bSSFP; aorta; aortic motion; displacement; nonrigid registration; ROOT MOTION; MRI; REGISTRATION; RELIABILITY; VELOCITY; STRESS; ECG;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Aortic motion has direct impact on the mechanical stresses acting on the aorta. In aortic disease, increased stiffness of the aorta may lead to decreased aortic motion over time, which could be a predictor for aortic dissection or rupture. This study investigates the reproducibility of obtaining 3D displacement and diameter maps quantified using accelerated 3D cine MRI at 3 T. Methods: A noncontrast-enhanced, free-breathing 3D cine sequence based on balanced SSFP and pseudo-spiral undersampling with high spatial isotropic resolution was developed (spatial/temporal resolution [1.6mm](3)/67 ms). The thoracic aorta of 14 healthy volunteers was prospectively scanned three times at 3 T: twice on the same day and a third time 2weeks later. Aortic displacement was calculated using iterative closest point nonrigid registration of manual segmentations of the 3D aorta at end-systole and mid-diastole. Interexamination and interobserver regional analysis of mean displacement for five regions of interest was performed using Bland-Altman analysis. Additionally, a complementary voxel-by-voxel analysis was done, allowing a more local inspection of the method. Results: No significant differences were found in mean and maximum displacement for any of the regions of interest for the interexamination and interobserver analysis. The maximum displacement measured in the lower half of the ascending aorta was 11.0 +/- 3.4mm(range: 3.0-17.5mm) for the first scan. The smallest detectable change in mean displacement in the lower half of the ascending aorta was 3 mm. Conclusion: Detailed 3D cine balanced SSFP at 3 T allows for reproducible quantification of systolic-diastolic mean aortic displacement within acceptable limits.
引用
收藏
页码:466 / 480
页数:15
相关论文
共 50 条
  • [1] Reproducibility of 3D thoracic aortic displacement from 3D cine balanced SSFP at 3 T without contrast enhancement
    Merton, Renske
    Bosshardt, Daan
    Strijkers, Gustav J.
    Nederveen, Aart J.
    Schrauben, Eric M.
    van Ooij, Pim
    MAGNETIC RESONANCE IN MEDICINE, 2023, 91 (02) : 466 - 480
  • [2] Artifact suppression of SSFP cine sequences at 3T using a novel automatic 3D shimming algorithm
    Tamara Rothstein
    Gabriel C Camargo
    Daniel C Quintella
    Elsa Fernandes
    Ralph Strecker
    Andreas Greiser
    Maria Eduarda Derenne
    Marceu Lima
    Joao J Moojen
    Patricia B Rizzi
    Ronaldo SL Lima
    Ilan Gottlieb
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [3] Single breathhold 3D balanced SSFP coronary MRA at 3.0T: a reproducibility study
    Sahar Soleimanifard
    Matthias Stuber
    Allison Hays
    Robert G Weiss
    Michael Schär
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [4] Fast 3D T2-weighted imaging using variable flip angle transition into driven equilibrium (3D T2-TIDE) balanced SSFP for prostate imaging at 3T
    Srinivasan, Subashini
    Wu, Holden H.
    Sung, Kyunghyun
    Margolis, Daniel J. A.
    Ennis, Daniel B.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 442 - 451
  • [5] 1119 Direct comparison of the signal-to-noise ratio for 3D and 2D balanced SSFP cine imaging
    Dana C Peters
    Daniel A Herzka
    Reza Nezafat
    Warren J Manning
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [6] 3D Velocity Quantification in the Heart: Improvements by 3D PC-SSFP
    Rolf, Marijn P.
    Hofman, Mark B. M.
    Kuijer, Joost P. A.
    van Rossum, Albert C.
    Heethaar, Rob M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) : 947 - 955
  • [7] The Holy Grail in diagnostic neuroradiology: 3T or 3D?
    Barkhof, Frederik
    Pouwels, Petra J. W.
    Wattjes, Mike P.
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 449 - 456
  • [8] The Holy Grail in diagnostic neuroradiology: 3T or 3D?
    Frederik Barkhof
    Petra J. W. Pouwels
    Mike P. Wattjes
    European Radiology, 2011, 21 : 449 - 456
  • [9] Reproducibility of 3D chemical exchange saturation transfer (CEST) contrasts in the healthy brain at 3T
    Cronin, Alicia E.
    Liebig, Patrick
    Detombe, Sarah A.
    Duggal, Neil
    Bartha, Robert
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [10] Routine 3D SSFP cine imaging for improved analysis of myocardial volumetry and deformation
    Bram Ruijsink
    María N Velasco Forte
    Miguel S Vieira
    Rene M Botnar
    Tarique Hussain
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)