Incidence of Cholecystitis After Endoscopic Biliary Drainage Using a Low Axial Force Covered Self-Expandable Metallic Stent in Patients With Malignant Distal Biliary Obstruction: A Multicenter Prospective Study

被引:0
作者
Minato, Naoki [1 ]
Okuwaki, Kosuke [1 ]
Watanabe, Masafumi [1 ]
Woo, Jun [2 ]
Matsumoto, Takaaki [3 ]
Tadehara, Masayoshi [4 ]
Kaneko, Toru [5 ]
Ishizaki, Junro [1 ]
Iwai, Tomohisa [1 ]
Imaizumi, Hiroshi [4 ]
Kida, Mitsuhiro [1 ]
Haradome, Hiroki [6 ]
Kusano, Chika [1 ]
机构
[1] Kitasato Univ, Sch Med, Dept Gastroenterol, Sagamihara, Japan
[2] Jikei Univ, Sch Med, Dept Radiol, Tokyo, Japan
[3] Isehara Kyodo Hosp, Dept Gastroenterol, Isehara, Japan
[4] Japan Community Hlth Care Org Sagamino Hosp, Dept Gastroenterol, Sagamihara, Japan
[5] Kitasato Med Ctr, Dept Gastroenterol, Saitama, Japan
[6] Kitasato Univ, Sch Med, Dept Radiol Adv Med, Sagamihara, Japan
关键词
axial force; cholecystitis; endoscopic biliary drainage; self-expandable metallic stent; RISK-FACTOR; PANCREATITIS; PLACEMENT;
D O I
10.1111/jgh.16824
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and AimNo prospective studies have verified the incidence of cholecystitis in patients using the covered self-expandable metallic stent. In this study, we aimed to investigate the incidence of cholecystitis and its risk factors after low axial force covered self-expandable metallic stent placement for malignant distal biliary obstruction.MethodsThis multicenter prospective study included patients diagnosed with unresectable distal biliary obstruction between November 2019 and October 2022 who underwent low axial force covered self-expandable metallic stent placement.ResultsThe technical success in the 93 analyzed patients was 100% and clinical success was 98.9%. The 70-mm covered self-expandable metallic stent was the most used in 53 patients (57.0%), followed by the 80-mm type in 27 patients (29.0%), 60-mm type in 12 patients (12.9%), and 50-mm type in 1 patient (1.1%). Cholecystitis after covered self-expandable metallic stent placement occurred in six patients (6.5%). The median time to onset was 46 days (range, 16-315 days), with 1 case in the early stage and five cases in the late stage. There was one mild case, one moderate case, and four severe cases. The presence of tumor involvement at the orifice of the cystic duct was identified as an independent risk factor (odds ratio, 17.0; 95% confidence interval, 1.5-195.1; p = 0.023).ConclusionsThe presence of tumor involvement at the orifice of the cystic duct was an independent risk factor for the development of cholecystitis after low axial covered self-expandable metallic stent placement. Trial registration: University Hospital Medical Information Network (UMIN) (, registration number: UMIN 000038209)ConclusionsThe presence of tumor involvement at the orifice of the cystic duct was an independent risk factor for the development of cholecystitis after low axial covered self-expandable metallic stent placement. Trial registration: University Hospital Medical Information Network (UMIN) (, registration number: UMIN 000038209)
引用
收藏
页码:502 / 509
页数:8
相关论文
共 14 条
  • [1] Endoscopic biliary stenting: indications, choice of stents, and results: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline - Updated October 2017
    Dumonceau, Jean-Marc
    Tringali, Andrea
    Papanikolaou, Ioannis S.
    Blero, Daniel
    Mangiavillano, Benedetto
    Schmidt, Arthur
    Vanbiervliet, Geoffroy
    Costamagna, Guido
    Deviere, Jacques
    Garcia-Cano, Jesus
    Gyoekeres, Tibor
    Hassan, Cesare
    Prat, Frederic
    Siersema, Peter D.
    van Hooft, Jeanin E.
    [J]. ENDOSCOPY, 2018, 50 (09) : 910 - 930
  • [2] Guidelines for gastroenterological endoscopy in patients undergoing antithrombotic treatment
    Fujimoto, Kazuma
    Fujishiro, Mitsuhiro
    Kato, Mototsugu
    Higuchi, Kazuhide
    Iwakiri, Ryuichi
    Sakamoto, Choitsu
    Uchiyama, Shinichiro
    Kashiwagi, Atsunori
    Ogawa, Hisao
    Murakami, Kazunari
    Mine, Tetsuya
    Yoshino, Junji
    Kinoshita, Yoshikazu
    Ichinose, Masao
    Matsui, Toshiyuki
    [J]. DIGESTIVE ENDOSCOPY, 2014, 26 (01) : 1 - 14
  • [3] Cholecystitis after metallic stent placement in patients with malignant distal biliary obstruction
    Isayama, Hiroyuki
    Kawabe, Takao
    Nakai, Yousuke
    Tsujino, Takeshi
    Sasahira, Naoki
    Yamamoto, Natsuyo
    Arizumi, Toshihiko
    Togawa, Osamu
    Matsubara, Saburou
    Ito, Yukiko
    Sasaki, Takashi
    Hirano, Kenji
    Toda, Nobuo
    Komatsu, Yutaka
    Tada, Minoru
    Yoshida, Haruhiko
    Omata, Masao
    [J]. CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2006, 4 (09) : 1148 - 1153
  • [4] TOKYO criteria 2014 for transpapillary biliary stenting
    Isayama, Hiroyuki
    Hamada, Tsuyoshi
    Yasuda, Ichiro
    Itoi, Takao
    Ryozawa, Shomei
    Nakai, Yousuke
    Kogure, Hirofumi
    Koike, Kazuhiko
    [J]. DIGESTIVE ENDOSCOPY, 2015, 27 (02) : 259 - 264
  • [5] Measurement of radial and axial forces of biliary self-expandable metallic stents
    Isayama, Hiroyuki
    Nakai, Yousuke
    Toyokawa, Yoshihide
    Togawa, Osamu
    Gon, Chimyon
    Ito, Yukiko
    Yashima, Yoko
    Yagioka, Hiroshi
    Kogure, Hirofumi
    Sasaki, Takashi
    Arizumi, Toshihiko
    Matsubara, Saburo
    Yamamoto, Natsuyo
    Sasahira, Naoki
    Hirano, Kenji
    Tsujino, Takeshi
    Toda, Nobuo
    Tada, Minoru
    Kawabe, Takao
    Omata, Masao
    [J]. GASTROINTESTINAL ENDOSCOPY, 2009, 70 (01) : 37 - 44
  • [6] Risk factors for early and late cholecystitis after covered metal stent placement for distal biliary obstruction
    Ishii, Tatsuya
    Hayashi, Tsuyoshi
    Yamazaki, Hajime
    Nakamura, Risa
    Iwano, Kosuke
    Ando, Ryo
    Toyonaga, Haruka
    Kin, Toshifumi
    Takahashi, Kuniyuki
    Katanuma, Akio
    [J]. JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2023, 30 (10) : 1180 - 1187
  • [7] Association of covered metallic stents with cholecystitis and stent migration in malignant biliary stricture
    Jang, Sunguk
    Stevens, Tyler
    Parsi, Mansour
    Lopez, Rocio
    Zuccaro, Gregory
    Dumot, John
    Vargo, John J.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2018, 87 (04) : 1061 - 1070
  • [8] Identification of risk factors for obstructive cholecystitis following placement of biliary stent in unresectable malignant biliary obstruction: a 5-year retrospective analysis in single center
    Jung, Jang Han
    Park, Se Woo
    Hyun, Bomi
    Lee, Jin
    Koh, Dong Hee
    Chung, Doocheol
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2021, 35 (06): : 2679 - 2689
  • [9] Risk factors for pancreatitis following transpapillary self-expandable metal stent placement
    Kawakubo, Kazumichi
    Isayama, Hiroyuki
    Nakai, Yousuke
    Togawa, Osamu
    Sasahira, Naoki
    Kogure, Hirofumi
    Sasaki, Takashi
    Matsubara, Saburo
    Yamamoto, Natsuyo
    Hirano, Kenji
    Tsujino, Takeshi
    Toda, Nobuo
    Tada, Minoru
    Omata, Masao
    Koike, Kazuhiko
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (03): : 771 - 776
  • [10] Metallic stent with high axial force as a risk factor for cholecystitis in distal malignant biliary obstruction
    Nakai, Yousuke
    Isayama, Hiroyuki
    Kawakubo, Kazumichi
    Kogure, Hirofumi
    Hamada, Tsuyoshi
    Togawa, Osamu
    Ito, Yukiko
    Matsubara, Saburo
    Arizumi, Toshihiko
    Yagioka, Hiroshi
    Takahara, Naminatsu
    Uchino, Rie
    Mizuno, Suguru
    Miyabayashi, Koji
    Yamamoto, Keisuke
    Sasaki, Takashi
    Yamamoto, Natsuyo
    Hirano, Kenji
    Tada, Minoru
    Koike, Kazuhiko
    [J]. JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2014, 29 (07) : 1557 - 1562