Determination of trace heavy metal ion Tl(I) in water by energy dispersive X-ray fluorescence spectrometry using prussian blue dispersed on solid sepiolite

被引:1
作者
Liu, Weitao [1 ]
Deng, Lu [1 ]
Li, Hao [1 ,3 ]
Lin, Wencong [1 ]
Yang, Yingzhuo [1 ]
Zhang, Linlin [2 ,4 ]
Zhu, Ruirui [3 ]
Zou, Jun [1 ]
Niu, Hongyu [1 ]
Wang, Yeyao [2 ]
Tong, Chunyi [1 ]
Zhu, Rilong [1 ,4 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, Coll Biol, Coll Environm Sci & Engn, Changsha 410082, Peoples R China
[2] China Natl Environm Monitoring Ctr, Beijing 100049, Peoples R China
[3] Hunan Prov Ecol Environm Monitoring Ctr, Changsha 410082, Peoples R China
[4] Shanxi Key Lab Environm Monitoring & Forewarning T, Xian 710006, Shanxi, Peoples R China
关键词
Energy dispersive X-ray fluorescence spectrometry; Tl(I); Prussian blue/sepiolite; Water analysis; Pre-enrichment; ATOMIC-ABSORPTION-SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; PHASE EXTRACTION; AQUEOUS-SOLUTION; THALLIUM; ADSORPTION; CESIUM; GRAPHITE; PRECONCENTRATION; COORDINATION;
D O I
10.1016/j.talanta.2024.127295
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
X-ray fluorescence (XRF) offers the advantage of performing measurements without damaging or consuming the sample, enabling rapid and simultaneous multi-element analysis. It has been widely applied in environmental monitoring, materials science, geology, and medicine, but not in water. Here, a novel method is proposed that combines energy-dispersive X-ray fluorescence spectroscopy (EDXRF) with prussian blue dispersed on solid sepiolite nanomaterials (PB/SEP) and an integrated enrichment-separation device to detect trace heavy metal ion Tl(I) in water environments. The water sample passes through the detachable enrichment component, and subsequently, PB/SEP is used as a solid adsorbent for the pre-enrichment of Tl(I) in the water sample. This process eliminates the cumbersome separation steps and saves analysis time. The research elucidates the impact of sample pH, flow rate, volume, and interfering ions on elemental recoveries, demonstrating that the proposed method offers a low detection limit of 0.057 mu g/L, but also maintains high precision, with the RSD of less than 4.39 %. Furthermore, the PB/SEP magnetic nanocomposite was successfully applied to the tap water sample and river water sample with recoveries ranging from 93.5 % to 128.3 %, confirming the accuracy and practicality of the analytical method.
引用
收藏
页数:9
相关论文
共 50 条
[21]   CRITICAL COMPARISON OF PRECONCENTRATION METHODS FOR TRACE ION DETERMINATION BY ENERGY AND WAVELENGTH DISPERSIVE-X-RAY SPECTROMETRY [J].
LEYDEN, DE ;
WEGSCHEIDER, W ;
BODNAR, WB .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1979, 7 (02) :85-108
[22]   Direct determination of chromium (III) complexed with humic acid by energy dispersive X-ray fluorescence spectrometry [J].
Ohashi, K ;
Hada, T ;
Ohashi, A ;
Imura, H .
BUNSEKI KAGAKU, 2005, 54 (05) :387-390
[23]   Graphene oxide as a solid sorbent for the preconcentration of cobalt, nickel, copper, zinc and lead prior to determination by energy-dispersive X-ray fluorescence spectrometry [J].
Zawisza, Beata ;
Sitko, Rafal ;
Malicka, Ewa ;
Talik, Ewa .
ANALYTICAL METHODS, 2013, 5 (22) :6425-6430
[24]   Energy-dispersive X-ray fluorescence spectrometry combined with dispersive liquid-liquid microextraction for simultaneous determination of zinc and copper in water samples [J].
Pytlakowska, Katarzyna ;
Sitko, Rafal .
ANALYTICAL METHODS, 2013, 5 (21) :6192-6199
[25]   Rapid Determination of Toxic Trace Metals As, Hg, Tl, and Pb in Hair by Monochromatic Excitation X-ray Fluorescence Spectrometry [J].
Wu, Shihao ;
Zhao, Peng ;
Wang, Aihua ;
Dong, Linpei ;
Wu, Xiaojun ;
Wang, Jifen ;
Zhang, Yunfeng .
BIOLOGICAL TRACE ELEMENT RESEARCH, 2025, 203 (03) :1776-1785
[26]   APPLICATION OF ION CHROMATOGRAPHY AND ENERGY DISPERSIVE X-RAY FLUORESCENCE SPECTROMETRY FOR EXAMINATION OF CHEMICAL COMPOSITION OF MINERAL FERTILIZERS [J].
Michalski, Rajmund ;
Lyko, Aleksandra ;
Szopa, Sebastian .
ARCHIVES OF ENVIRONMENTAL PROTECTION, 2011, 37 (02) :93-107
[27]   Determination of copper content in pyrotechnics used for fireworks and firecrackersbased on Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF) [J].
Wu Jun-yi ;
Xiao Huan-xin .
PROCEEDINGS OF THE 2017 5TH INTERNATIONAL CONFERENCE ON FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY (FMSMT 2017), 2017, 130 :6-11
[28]   Determination of titanium content in pyrotechnics used for fireworks and firecrackersbased on Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF) [J].
Wu Jun-yi ;
Xiao Huan-xin .
PROCEEDINGS OF THE 2017 5TH INTERNATIONAL CONFERENCE ON FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY (FMSMT 2017), 2017, 130 :12-17
[29]   Magnetic Solid Phase Microextraction using CoFe2O4 Nanoparticles for Determination of Cu, Cd, Pb and V in Sugar Cane Spirit Samples by Energy Dispersive X-Ray Fluorescence Spectrometry [J].
Meira, Lucilia A. ;
Almeida, Jorge S. ;
Dias, Fabio de S. ;
Teixeira, Leonardo S. G. .
BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 6 (22) :60-66
[30]   Direct multielement determination of Cd, Pb, Fe, and Mn in ground coffee samples using energy dispersive X-ray fluorescence spectrometry [J].
Almeida, Jorge S. ;
Meira, Lucilia A. ;
Oliveira, Maiara S. ;
Teixeira, Leonardo S. G. .
X-RAY SPECTROMETRY, 2021, 50 (01) :2-8