Determination of trace heavy metal ion Tl(I) in water by energy dispersive X-ray fluorescence spectrometry using prussian blue dispersed on solid sepiolite

被引:0
作者
Liu, Weitao [1 ]
Deng, Lu [1 ]
Li, Hao [1 ,3 ]
Lin, Wencong [1 ]
Yang, Yingzhuo [1 ]
Zhang, Linlin [2 ,4 ]
Zhu, Ruirui [3 ]
Zou, Jun [1 ]
Niu, Hongyu [1 ]
Wang, Yeyao [2 ]
Tong, Chunyi [1 ]
Zhu, Rilong [1 ,4 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, Coll Biol, Coll Environm Sci & Engn, Changsha 410082, Peoples R China
[2] China Natl Environm Monitoring Ctr, Beijing 100049, Peoples R China
[3] Hunan Prov Ecol Environm Monitoring Ctr, Changsha 410082, Peoples R China
[4] Shanxi Key Lab Environm Monitoring & Forewarning T, Xian 710006, Shanxi, Peoples R China
关键词
Energy dispersive X-ray fluorescence spectrometry; Tl(I); Prussian blue/sepiolite; Water analysis; Pre-enrichment; ATOMIC-ABSORPTION-SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; PHASE EXTRACTION; AQUEOUS-SOLUTION; THALLIUM; ADSORPTION; CESIUM; GRAPHITE; PRECONCENTRATION; COORDINATION;
D O I
10.1016/j.talanta.2024.127295
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
X-ray fluorescence (XRF) offers the advantage of performing measurements without damaging or consuming the sample, enabling rapid and simultaneous multi-element analysis. It has been widely applied in environmental monitoring, materials science, geology, and medicine, but not in water. Here, a novel method is proposed that combines energy-dispersive X-ray fluorescence spectroscopy (EDXRF) with prussian blue dispersed on solid sepiolite nanomaterials (PB/SEP) and an integrated enrichment-separation device to detect trace heavy metal ion Tl(I) in water environments. The water sample passes through the detachable enrichment component, and subsequently, PB/SEP is used as a solid adsorbent for the pre-enrichment of Tl(I) in the water sample. This process eliminates the cumbersome separation steps and saves analysis time. The research elucidates the impact of sample pH, flow rate, volume, and interfering ions on elemental recoveries, demonstrating that the proposed method offers a low detection limit of 0.057 mu g/L, but also maintains high precision, with the RSD of less than 4.39 %. Furthermore, the PB/SEP magnetic nanocomposite was successfully applied to the tap water sample and river water sample with recoveries ranging from 93.5 % to 128.3 %, confirming the accuracy and practicality of the analytical method.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Determination of trace metals in drinking water using solid-phase extraction disks and X-ray fluorescence spectrometry
    Hou, XD
    Peters, HL
    Yang, Z
    Wagner, KA
    Batchelor, JD
    Daniel, MM
    Jones, BT
    APPLIED SPECTROSCOPY, 2003, 57 (03) : 338 - 342
  • [12] Determination of calcium and iodine in gall bladder stone using energy dispersive X-ray fluorescence spectrometry
    Ekinci, N
    Sahin, Y
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (01) : 167 - 171
  • [13] The determination of trace elements release from dental cements in artificial saliva by energy dispersive X-ray fluorescence spectrometry
    Ekinci, N.
    Bayindir, F.
    Bayindir, Y. Z.
    Ekinci, R.
    ANALYTICAL LETTERS, 2007, 40 (13) : 2476 - 2484
  • [14] Preconcentration with Chlorella vulgaris combined with energy dispersive X-ray fluorescence spectrometry for rapid determination of Cd in water
    Gan, Tingting
    Zhao, Nanjing
    Yin, Gaofang
    Chen, Min
    Wang, Xiang
    Hua, Hui
    ROYAL SOCIETY OPEN SCIENCE, 2020, 7 (05):
  • [15] Determination of trace chromium(VI) in drinking water using X-ray fluorescence spectrometry after solid-phase extraction
    Pedro R. Aranda
    Susana Moyano
    Luis D. Martinez
    Irma E. De Vito
    Analytical and Bioanalytical Chemistry, 2010, 398 : 1043 - 1048
  • [16] Zirconium and hafnium determination by energy dispersive X-ray fluorescence with solid phase preconcentration
    PeraltaZamora, P
    CornejoPonce, L
    Bueno, MIMS
    Martins, JW
    TALANTA, 1997, 44 (05) : 811 - 816
  • [17] Study of metal-loaded activated charcoals for the separation and determination of selenium species by energy dispersive X-ray fluorescence analysis
    Latva, S
    Peräniemi, S
    Ahlgrén, M
    ANALYTICA CHIMICA ACTA, 2003, 478 (02) : 229 - 235
  • [18] Determination of selenium by X-ray fluorescence spectrometry using dispersive solid-phase microextraction with multiwalled carbon nanotubes as solid sorbent
    Skorek, Robert
    Turek, Edyta
    Zawisza, Beata
    Margui, Eva
    Queralt, Ignasi
    Stempin, Marek
    Kucharski, Piotr
    Sitko, Rafal
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (10) : 1688 - 1693
  • [19] Determination of lanthanide and actinide elements by energy dispersive x-ray fluorescence spectrometry applying DLLME preconcentration and dried spot
    Sa, Ivero P.
    Almeida, Ohana N.
    Lima, Daniel De C.
    da Silva, Erik G. P.
    Santos, Luana N.
    Luzardo, Francisco H. M.
    Velasco, Fermin G.
    Gonzalez, Mario H.
    Amorim, Fabio A. C.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 182
  • [20] Determination of Zn in Dry Feeds for Cats and Dogs by Energy-Dispersive X-Ray Fluorescence Spectrometry
    Avila, Dayara Virginia L.
    Souza, Sidnei O.
    Costa, Silvanio Silverio L.
    Araujo, Rennan Geovanny O.
    Garcia, Carlos Alexandre B.
    Alves, Jost do Patrocinio H.
    Passos, Elisangela A.
    JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (06) : 1572 - 1575