Scoliosis instrumentation alters primary and coupled motions of the spine: An in vitro study using entire thoracolumbar spine and rib cage specimens

被引:0
|
作者
Liebsch, Christian [1 ]
Obid, Peter [2 ]
Vogt, Morten [1 ]
Schlager, Benedikt [1 ]
Wilke, Hans-Joachim [1 ]
机构
[1] Ulm Univ, Inst Orthopaed Res & Biomech, Trauma Res Ctr Ulm, Med Ctr, Ulm, Germany
[2] Freiburg Univ, Dept Orthopaed & Trauma Surg, Med Ctr, Freiburg, Germany
来源
JOR SPINE | 2024年 / 7卷 / 04期
关键词
adolescent idiopathic scoliosis; biomechanics; coupled motions; in vitro study; lumbar spine; posterior instrumentation; range of motion; rib cage; thoracic spine; POSTURE; ROTATIONS;
D O I
10.1002/jsp2.70028
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Effects of rigid posterior instrumentation on the three-dimensional post-operative spinal flexibility are widely unknown. Purpose of this in vitro study was to quantify these effects for characteristic adolescent idiopathic scoliosis instrumentations. Methods: Six fresh frozen human thoracic and lumbar spine specimens (C7-S) with entire rib cage from young adult donors (26-45 years) without clinically relevant deformity were loaded quasi-statically with pure moments of 5 Nm in flexion/extension, lateral bending, and axial rotation. Primary and coupled motions of all segments were measured using optical motion tracking. Specimens were tested without instrumentation and with posterior rod instrumentations ranging from T2 to L1 (for Lenke Type 2) and from T8 to L3 (for Lenke Type 5) based on survey results among spinal deformity surgeons. Statistical differences were evaluated using the pairwise Friedman test. Results: Primary ranges of motion were significantly (p < 0.05) reduced in all six motion directions in the entire thoracic spine (T1-L1) for both instrumentations, but solely in extension and axial rotation in the entire lumbar spine (L1-S) for T8-L3 instrumentation. Without instrumentation, strong ipsilateral axial rotation during primary lateral bending and strong contralateral lateral bending during primary axial rotation were detected in the thoracic spine (T1-L1) and slight inverse coupled motions in the lumbar spine (L1-S). While coupled axial rotation was significantly (p < 0.05) reduced, especially in the upper thoracic spine (T1-T5) for T2-L1 instrumentation and in the lumbar spine (L1-S) for T8-L3 instrumentation, coupled lateral bending was solely significantly (p < 0.05) reduced in the upper thoracic spine (T1-T5) for T2-L1 instrumentation. Coupled motions in primary flexion and extension were non-existent and not affected by any fixation (p > 0.05). Conclusions: Instrumentation reduces the primary flexibility and diminishes the natural coupling behavior between lateral bending and axial rotation, primarily in the upper thoracic spine, potentially causing correction loss and junctional deformity in the long-term.
引用
收藏
页数:9
相关论文
共 13 条
  • [1] The effect of follower load on the intersegmental coupled motion characteristics of the human thoracic spine: An in vitro study using entire rib cage specimens
    Liebsch, Christian
    Graf, Nicolas
    Wilke, Hans-Joachim
    JOURNAL OF BIOMECHANICS, 2018, 78 : 36 - 44
  • [2] In vitro coupled motions of the whole human thoracic and lumbar spine with rib cage
    Orbach, Mattan R.
    Mahoney, Jonathan
    Bucklen, Brandon S.
    Balasubramanian, Sriram
    JOR SPINE, 2023, 6 (03):
  • [4] EUROSPINE 2016 FULL PAPER AWARD: Wire cerclage can restore the stability of the thoracic spine after median sternotomy: an in vitro study with entire rib cage specimens
    Liebsch, Christian
    Graf, Nicolas
    Wilke, Hans-Joachim
    EUROPEAN SPINE JOURNAL, 2017, 26 (05) : 1401 - 1407
  • [5] EUROSPINE 2016 FULL PAPER AWARD: Wire cerclage can restore the stability of the thoracic spine after median sternotomy: an in vitro study with entire rib cage specimens
    Christian Liebsch
    Nicolas Graf
    Hans-Joachim Wilke
    European Spine Journal, 2017, 26 : 1401 - 1407
  • [6] In vitro comparison of personalized 3D printed versus standard expandable titanium vertebral body replacement implants in the mid-thoracic spine using entire rib cage specimens
    Liebsch, Christian
    Aleinikov, Viktor
    Kerimbayev, Talgat
    Akshulakov, Serik
    Kocak, Tugrul
    Vogt, Morten
    Jansen, Jan Ulrich
    Wilke, Hans-Joachim
    CLINICAL BIOMECHANICS, 2020, 78 (78)
  • [7] How does thoracic scoliosis surgery affect thoracolumbar spinal flexibility and lumbar intradiscal pressure? An in vitro study confirming the importance of the rib cage
    Liebsch, Christian
    Obid, Peter
    Vogt, Morten
    Schlager, Benedikt
    Wilke, Hans-Joachim
    EUROPEAN SPINE JOURNAL, 2025, 34 (01) : 8 - 16
  • [8] Stabilizing effect of the rib cage on adjacent segment motion following thoracolumbar posterior fixation of the human thoracic cadaveric spine: A biomechanical study
    Rahm, Mark D.
    Brooks, Daina M.
    Harris, Jonathan A.
    Hart, Robert A.
    Hughes, Jessica L.
    Ferrick, Bryan J.
    Bucklen, Brandon S.
    CLINICAL BIOMECHANICS, 2019, 70 : 217 - 222
  • [9] Posterior instrumentation reduces differences in spine stability as a result of different cage orientations -: An in vitro study
    Wang, ST
    Goel, VK
    Fu, CY
    Kubo, S
    Choi, W
    Liu, CL
    Chen, TH
    SPINE, 2005, 30 (01) : 62 - 67
  • [10] Thoracic Spinal Stability and Motion Behavior Are Affected by the Length of Posterior Instrumentation After Vertebral Body Replacement, but Not by the Surgical Approach Type: An in vitro Study With Entire Rib Cage Specimens
    Liebsch, Christian
    Kocak, Tugrul
    Aleinikov, Viktor
    Kerimbayev, Talgat
    Akshulakov, Serik
    Jansen, Jan Ulrich
    Vogt, Morten
    Wilke, Hans-Joachim
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2020, 8 (08):