Desiccant wheel combined with dual separated or single integrated heat pump? A comparison on energy consumption

被引:0
作者
Liu, Hequn [1 ,2 ]
Geng, Yining [1 ,2 ]
Tian, Shaochen [1 ,2 ]
Gao, Yafeng [3 ]
Su, Xing [1 ,2 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai 200092, Peoples R China
[2] Tongji Univ, Key Lab Performance Evolut & Control Engn Struct, Minist Educ, Shanghai 200092, Peoples R China
[3] Chongqing Univ, Joint Int Res Lab Green Bldg & Built Environm, Minist Educ, Chongqing 400044, Peoples R China
关键词
Desiccant wheel; Heat pump; Indoor humidity ratio; Energy consumption; AIR-CONDITIONING SYSTEM; RELATIVE-HUMIDITY; TEMPERATURE; PERFORMANCE; DEHUMIDIFICATION; HOT;
D O I
10.1016/j.enconman.2025.119624
中图分类号
O414.1 [热力学];
学科分类号
摘要
Heat pump combined desiccant wheel systems have significant potential for industrial dehumidification. This study aims to define the usage boundaries between desiccant wheel systems combined with dual separated or single integrated heat pumps by selecting the most energy-efficient system configuration under various conditions. Two simulation models are developed to evaluate energy consumption under typical summer conditions. Moreover, Harbin, Beijing, Shanghai, Guangzhou, and Kunming are selected as representative cities to compare the energy consumption of two systems across five typical climate zones: severe cold regions, cold regions, hot summer/cold winter regions, hot summer/mild winter regions, and temperate regions. Meanwhile, the energy consumption of the two systems is compared under three indoor humidity control targets of 40 %, 30 %, and 20 %, and four indoor cooling load conditions ranging from 15 to 30 kW. The results indicate that the Single-HP system has lower energy consumption in severe cold, cold, hot summer/cold winter, and hot summer/mild winter regions, while the Dual-HP system is more suitable for climate zones with a lower outdoor humidity ratio. Moreover, the Single-HP system saves more energy when the indoor relative humidity is controlled below 20 %, while the Dual-HP system is more efficient under more relaxed humidity control requirements. In addition, regardless of indoor cooling load conditions, the Single-HP system consistently consumes less energy than the Dual-HP system with the energy consumption gap widening as the cooling load increases.
引用
收藏
页数:15
相关论文
共 47 条
[1]   Study of a dry room in a battery manufacturing plant using a process model [J].
Ahmed, Shabbir ;
Nelson, Paul A. ;
Dees, Dennis W. .
JOURNAL OF POWER SOURCES, 2016, 326 :490-497
[2]   Predicting the impact of temperature and relative humidity on Salmonella growth and survival in sliced chard, broccoli and red cabbage [J].
Alves, Jade Morais ;
Alvarenga, Veronica Ortiz ;
da Silva, Ruthchelly Tavares ;
Pedrosa, Geany Targino de Souza ;
Silva, Francyeli Araujo ;
Bicca, Gerson Balbueno ;
Baldwin, Clif ;
Schaffner, Donald W. ;
Magnani, Marciane .
FOOD MICROBIOLOGY, 2024, 120
[3]   A systematic review on role of humidity as an indoor thermal comfort parameter in humid climates [J].
Amaripadath, D. ;
Rahif, R. ;
Velickovic, M. ;
Attia, S. .
JOURNAL OF BUILDING ENGINEERING, 2023, 68
[4]  
Ambat R, 2022, Humidity Electron, P1
[5]  
[Anonymous], 2022, Optimization toolbox version: 9.4 (R2022b)
[6]   Paddy rice stored under hermetic conditions: The effect of relative humidity, temperature and storage time in suppressing Sitophilus zeamais and impact on rice quality [J].
Carvalho, Maria Otilia ;
Fradinho, Patricia ;
Joao Martins, M. ;
Magro, Ana ;
Raymundo, Anabela ;
de Sousa, Isabel .
JOURNAL OF STORED PRODUCTS RESEARCH, 2019, 80 :21-27
[7]  
Fan J, 2010, J. Refrigeration and Air Conditioning, P81
[8]   Seasonal Variations of Indoor Microbial Exposures and Their Relation to Temperature, Relative Humidity, and Air Exchange Rate [J].
Frankel, Mika ;
Beko, Gabriel ;
Timm, Michael ;
Gustavsen, Sine ;
Hansen, Erik Wind ;
Madsen, Anne Mette .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2012, 78 (23) :8289-8297
[9]  
Ge F, 2020, Energy Convers Manag, P224
[10]   Energy savings potential of a desiccant assisted hybrid air source heat pump system for residential building in hot summer and cold winter zone in China [J].
Ge, Fenghua ;
Guo, Xinglong ;
Hu, Zicheng ;
Chu, Yi .
ENERGY AND BUILDINGS, 2011, 43 (12) :3521-3527