Aptamer-molecularly imprinted polymer sensors for the detection of bacteria in water

被引:11
作者
Agar, Meltem [1 ,2 ]
Laabei, Maisem [3 ,4 ]
Leese, Hannah S. [2 ,5 ]
Estrela, Pedro [1 ,2 ]
机构
[1] Univ Bath, Dept Elect & Elect Engn, Bath BA2 7AY, England
[2] Univ Bath, Ctr Bioengn & Biomed Technol CBio, Bath BA2 7AY, England
[3] Univ Bath, Dept Life Sci, Bath BA2 7AY, England
[4] Univ Bristol, Sch Cellular & Mol Med, Bristol BS8 1TD, England
[5] Univ Bath, Dept Chem Engn, Bath BA2 7AY, England
关键词
Escherichia coli; Staphylococcus aureus; Molecular imprinted polymer; Aptamer; Electrochemical sensor; Capacitance; Bacterial detection; OUTBREAKS; RECOGNITION; APTASENSOR; ANTIGEN;
D O I
10.1016/j.bios.2025.117136
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Bacteria pose a significant threat to human health as they can cause diseases and outbreaks; therefore rapid, easy, and specific detection of bacteria in a short time is crucial. Various methods such as polymerase chain reaction and enzyme-linked immunosorbent assay have been developed for bacteria detection. However, most of these methods require sample preparation, trained personnel, and 2-4 days for identification. In this study, an electrochemical sensor has been developed in which a molecularly imprinted polymer (MIP) and aptamer were used together as a bioreceptor for the multiplexed detection of Staphylococcus aureus and Escherichia coli. Non-Faradaic electrochemical impedance spectroscopy (EIS) was employed to assess bacterial detection. Sensor performance was assessed in buffer solution, deionized water and spiked tap water. Aptamer-molecularly imprinted polymer (Apta-MIP) based electrochemical sensors demonstrate high sensitivity and selectivity for the detection of S. aureus and E . coli, with limits of detection of 4 CFU/mL and 2 CFU/mL, respectively. Additionally, these sensors exhibited a broad dynamic range from 1 CFU/mL to 108 CFU/mL. The Apta-MIPs performance surpasses those obtained for Aptasensors alone and MIPs alone, demonstrating the high efficiency of the double recognition effect that originates from the affinity between aptamer and bacteria and target-specific cavities on the polymer. This is the first study in which aptamers and imprinted polymers were used as a hybrid bioreceptors for multiplexed detection of bacteria. The Apta-MIP sensors produced in this study can be used as a point-of-care diagnostic tool for bacteria-related diseases and test of water quality.
引用
收藏
页数:8
相关论文
共 47 条
[21]   Whole cell based microcontact imprinted capacitive biosensor for the detection of Escherichia coli [J].
Idil, Neslihan ;
Hedstrom, Martin ;
Denizli, Adil ;
Mattiasson, Bo .
BIOSENSORS & BIOELECTRONICS, 2017, 87 :807-815
[22]   Biosensors for detection of pathogenic bacteria [J].
Ivnitski, D ;
Abdel-Hamid, I ;
Atanasov, P ;
Wilkins, E .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (07) :599-624
[23]   WHO publishes updated list of bacterial priority pathogens [J].
Jesudason, Timothy .
LANCET MICROBE, 2024, 5 (09)
[24]   Highly sensitive dual mode electrochemical platform for microRNA detection [J].
Jolly, Pawan ;
Batistuti, Marina R. ;
Miodek, Anna ;
Zhurauski, Pavel ;
Mulato, Marcelo ;
Lindsay, Mark A. ;
Estrela, Pedro .
SCIENTIFIC REPORTS, 2016, 6
[25]   Aptamer-MIP hybrid receptor for highly sensitive electrochemical detection of prostate specific antigen [J].
Jolly, Pawan ;
Tamboli, Vibha ;
Harniman, Robert L. ;
Estrela, Pedro ;
Allender, Chris J. ;
Bowen, Jenna L. .
BIOSENSORS & BIOELECTRONICS, 2016, 75 :188-195
[26]   Harnessing aptamers for electrochemical detection of endotoxin [J].
Kim, Sung-Eun ;
Su, Wenqiong ;
Cho, MiSuk ;
Lee, Youngkwan ;
Choe, Woo-Seok .
ANALYTICAL BIOCHEMISTRY, 2012, 424 (01) :12-20
[27]   Aptamers: Problems, Solutions and Prospects [J].
Lakhin, A. V. ;
Tarantul, V. Z. ;
Gening, L. V. .
ACTA NATURAE, 2013, 5 (04) :34-43
[28]   Microbial agents associated with waterborne diseases [J].
Leclerc, H ;
Schwartzbrod, L ;
Dei-Cas, E .
CRITICAL REVIEWS IN MICROBIOLOGY, 2002, 28 (04) :371-409
[29]   Fluorometric aptasensor for cadmium(II) by using an aptamer-imprinted polymer as the recognition element [J].
Li, Shuhuai ;
Ma, Xionghui ;
Pang, Chaohai ;
Tian, Hai ;
Xu, Zhi ;
Yang, Yan ;
Lv, Daizhu ;
Ge, Huilin .
MICROCHIMICA ACTA, 2019, 186 (12)
[30]   Application of a novel electrosynthesized polydopamine-imprinted film to the capacitive sensing of nicotine [J].
Liu, Kai ;
Wei, Wan-Zhi ;
Zeng, Jin-Xiang ;
Liu, Xiao-Ying ;
Gao, Yan-Ping .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (04) :724-729