Fully Integrated Centrifugal Microfluidics for Rapid Exosome Isolation, Glycan Analysis, and Point-of-Care Diagnosis

被引:0
|
作者
Zhao, Xudong [1 ]
Liu, Xiang [1 ,2 ]
Chen, Tucan [1 ]
Xie, Han [1 ]
Li, Shunji [1 ]
Zhang, Ying [1 ]
Zhang, Hongwei [1 ]
Cao, Yulin [3 ,4 ]
Du, Wei [1 ]
Feng, Xiaojun [1 ]
Liu, Xin [1 ]
Li, Yiwei [1 ]
Chen, Peng [1 ]
Li, Qiubai [3 ,4 ]
Liu, Bi-Feng [1 ]
机构
[1] Huazhong Univ Sci & Technol, Coll Life Sci & Technol, Dept Biomed Engn, Key Lab Biomed Photon MOE,Wuhan Natl Lab Optoelect, Wuhan 430074, Peoples R China
[2] Huazhong Univ Sci & Technol, Wuhan Childrens Hosp, Tongji Med Coll, Dept Lab Med, Wuhan 430016, Peoples R China
[3] Huazhong Univ Sci & Technol, Union Hosp, Tongji Med Coll, Dept Rheumatol & Immunol, Wuhan 430022, Peoples R China
[4] Hubei Univ Sci & Technol, Hubei Engn Res Ctr Applicat Extracellular Vesicle, Xianning 437100, Peoples R China
基金
中国国家自然科学基金;
关键词
microfluidic chip; exosome separation; glycanprofiling analysis; diagnosis; breast cancer; EXTRACELLULAR VESICLES; MASS-SPECTROMETRY; CANCER; GLYCOSYLATION; BIOMARKER; PROGNOSIS; CELLS;
D O I
10.1021/acsnano.4c16988
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Exosomes present in the circulatory system demonstrate considerable promise for the diagnosis and treatment of diseases. Nevertheless, the complex nature of blood samples and the prevalence of highly abundant proteins pose a significant obstacle to prompt and effective isolation and functional evaluation of exosomes from blood. Here, we present a fully integrated lab-on-a-disc equipped with two nanofilters, also termed iExoDisc, which facilitates automated isolation of exosomes from 400 mu L blood samples within 45 min. By integrating the plasma separation module, highly abundant protein removal module, and nanopore membrane-based total isolation module, the resulting exosomes exhibited significantly increased purity (similar to 3-6-fold) compared to conventional ultracentrifugation and polymer precipitation. Additionally, we then successfully performed nontargeted and targeted glycan profiling on exosomes derived from clinical triple-negative breast cancer (TNBC) patients using MALDI-TOF-MS and lectin microarray containing 56 kinds of lectins. The findings from both methodologies indicated that galactosylation and sialylation exhibit potential as diagnostic indicators for TNBC. Finally, by utilizing the exosome-specific glycosylated protein CD63 as a proof-of-concept, we successfully realized the integration of point-of-care on-chip exosome separation and in situ detection with 2 h. Thus, the iExoDisc provides a potential approach to early cancer detection, liquid biopsy, and point-of-care diagnosis.
引用
收藏
页码:8948 / 8965
页数:18
相关论文
共 50 条
  • [21] Aptamer-based rapid diagnosis for point-of-care application
    Abhishek Futane
    Vigneswaran Narayanamurthy
    Pramod Jadhav
    Arthi Srinivasan
    Microfluidics and Nanofluidics, 2023, 27
  • [22] Diagnosis at gut point: rapid identification of pneumoperitoneum via point-of-care ultrasound
    Taylor, Matthew A.
    Merritt, Christopher H.
    Riddle, Philip J., Jr.
    DeGennaro, Carter J.
    Barron, Keith R.
    ULTRASOUND JOURNAL, 2020, 12 (01):
  • [23] Diagnosis at gut point: rapid identification of pneumoperitoneum via point-of-care ultrasound
    Matthew A. Taylor
    Christopher H. Merritt
    Philip J. Riddle
    Carter J. DeGennaro
    Keith R. Barron
    The Ultrasound Journal, 12
  • [24] Printed Divisional Optical Biochip for Multiplex Visualizable Exosome Analysis at Point-of-Care
    Yang, Xu
    Zhang, Zeying
    Wu, Yuanbin
    Wang, Huadong
    Yun, Yang
    Sun, Yali
    Xie, Hongfei
    Bogdanov, Bogdan
    Senyushkin, Pavel
    Chi, Jimei
    Lian, Zewei
    Wu, Dongdong
    Su, Meng
    Song, Yanlin
    ADVANCED MATERIALS, 2024, 36 (04)
  • [25] Fully integrated point-of-care blood cell count using multi-frame morphology analysis
    Zhang, Wenchang
    Li, Ya
    Chen, Bing
    Zhang, Yuan
    Du, Ziqiang
    Xiang, Feibin
    Hu, Yu
    Meng, Xiaochen
    Shang, Chunliang
    Liang, Shengfa
    Yang, Xiaonan
    Guan, Weihua
    BIOSENSORS & BIOELECTRONICS, 2023, 223
  • [26] Rapid point-of-care test for diagnosis of peritonitis in peritoneal dialysis patients
    Htay, Htay
    Choo, Jason Chon Jun
    Huang, Dorothy Hannah
    Jayaballa, Mathini
    Johnson, David W.
    Koniman, Riece
    Oei, Elizabeth Ley
    Suai, Tan Chieh
    Wu, Sin Yan
    Foo, Marjorie Wai Yin
    PERITONEAL DIALYSIS INTERNATIONAL, 2024, 44 (06): : 413 - 418
  • [27] A new point-of-care rapid test to aid in the diagnosis of bacterial vaginosis
    Chaudhuri, A
    Benham, P
    Tran, A
    Jackson, B
    Tamerius, J
    Soper, D
    CLINICAL CHEMISTRY, 2005, 51 : A252 - A252
  • [28] A rapid point-of-care device for the diagnosis of hepatitis delta virus infection
    Lempp, Florian A.
    Sakin, Volkan
    Nkongolo, Shirin
    Schnitzler, Paul
    Wedemeyer, Heiner
    Le Gal, Frederic
    Gordien, Emmanuel
    Yurdaydin, Cihan
    Urban, Stephan
    JOURNAL OF HEPATOLOGY, 2019, 70 (01) : E32 - E33
  • [29] A novel antibody avidity methodology for rapid point-of-care serological diagnosis
    Smolander, Hanna
    Koskinen, Janne O.
    Vainionpaa, Raija
    Meltola, Niko J.
    Lappalainen, Maija
    Hedman, Klaus
    Soini, Aleksi E.
    JOURNAL OF VIROLOGICAL METHODS, 2010, 166 (1-2) : 86 - 91
  • [30] A Rapid Point-of-Care Device for the Diagnosis of Hepatitis Delta Virus Infection
    Lempp, Florian
    Nkongolo, Shirin
    Schnitzler, Paul
    Urban, Stephan
    HEPATOLOGY, 2018, 68 : 1202A - 1203A