Advancements in 2D blood vessel angiography using magneto-thermo-acoustic imaging

被引:0
|
作者
Zhao, Fanzhe [1 ,2 ]
Li, Yanhong [1 ,2 ]
Liu, Guoqiang [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Shenyang, Peoples R China
关键词
magnetic nanoparticles (MNPs); thermal-acoustic imaging; angiographic agent; 16-channel array ultrasound transducer (16-CAUT); NANOPARTICLES; TOMOGRAPHY;
D O I
10.1088/1361-6463/adb0d5
中图分类号
O59 [应用物理学];
学科分类号
摘要
Based on the thermoacoustic (TA) effect of magnetic nanoparticles (MNPs), we propose a novel TA imaging method for 2D vascular distribution mapping under a single-pulse magnetic field. By numerically simulating the forward problem, we model the propagation process of the TA signal, incorporating gradient-concentration MNPs to demonstrate the functional imaging capabilities of MTA. We constructed a 2D vessel model based on real vessels for the inverse problem. By comparing the filtered inverse projection algorithm with the time-reversal method, we verified the feasibility of reconstructing the vessel model image using magnetic-thermo-imaging. One major innovation of this work is the development and use of a 16-channel array ultrasound (US) transducer (16-CAUT) with a center frequency of 2.25 MHz. This device represents a significant advancement, achieving a spatial resolution of 0.35 mm in vascular phantoms for the first time. Additionally, we investigated the effect of different US transducer sampling numbers on image quality. We evaluated the image metrics using root mean square error, peak signal-to-noise ratio, and structural similarity. contrast-to-noise ratio and full width at half maximum were also evaluated for different filtering levels. Our results demonstrated the effectiveness of bilateral filtering, a post-filtering method suited for time-reversal image reconstruction. This method is particularly effective at preserving edges while removing background noise, due to its capability to handle the boundary inversion of the acoustic source. Experimentally, our magneto-thermo-acoustic imaging platform achieved high contrast and a spatial resolution greater than 0.35 mm, demonstrating the potential to assist in image monitoring for vascular thrombolysis therapy.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Magnetic actuation for magnetic nanoparticles under magneto-thermo-acoustic imaging
    Zhao, Fanzhe
    Li, Yanhong
    Liu, Guoqiang
    AIP ADVANCES, 2025, 15 (02)
  • [2] PROPERTIES FOR A 2D MULTIPLEXED ARRAY FOR ACOUSTIC IMAGING
    GELLY, JF
    MAERFELD, C
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1982, 29 (03): : 192 - 193
  • [3] Investigating Large 2D Arrays for Photoacoustic and Acoustic Imaging using CMUT Technology
    Vaithilingam, Srikant
    Ma, Te-Jen
    Furukawa, Yukio
    Oralkan, Oemer
    Kamaya, Aya
    Torashima, Kazutoshi
    Kupnik, Mario
    Wygant, Ira O.
    Zhuang, Xuefeng
    Jeffrey, R. Brooke, Jr.
    Khuri-Yakub, Butrus T.
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1238 - +
  • [4] Harvesting Magneto-Acoustic Waves Using Magnetic 2D Chromium Telluride (CrTe3)
    Gowda, Chinmayee Chowde
    Kartsev, Alexey
    Tiwari, Nishant
    Sarkar, Suman
    Alexander, Safronov A.
    Chaudhary, Varun
    Tiwary, Chandra Sekhar
    SMALL, 2024, 20 (47)
  • [5] Adaptive vessel tracking: Automated computation of vessel trajectories for improved efficiency in 2D coronary MR angiography
    Saranathan, M
    Ho, VB
    Hood, MN
    Foo, TKF
    Hardy, CJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 368 - 373
  • [6] 2D Localisation Using Magneto-Inductive Waveguides
    Dima, Georgiana
    Spanos, Ioannis
    Stevens, Christopher J.
    2024 EIGHTEENTH INTERNATIONAL CONGRESS ON ARTIFICIAL MATERIALS FOR NOVEL WAVE PHENOMENA, METAMATERIALS 2024, 2024,
  • [7] Blood flow and velocity estimation based on vessel transit time by combining 2D and 3D X-ray angiography
    Bogunovic, Hrvoje
    Loncaric, Sven
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 2, 2006, 4191 : 117 - 124
  • [8] Study on 2D magneto-acousto-electrical tomography imaging reconstruction and imaging factors
    Xia, Hui
    Liu, Guo-Qiang
    Guo, Liang
    Huang, Xin
    Chen, Jing
    Dianzi Keji Daxue Xuebao/Journal of the University of Electronic Science and Technology of China, 2015, 44 (01): : 150 - 154
  • [9] A simple method for quantitative imaging of 2D acoustic fields using refracto-vibrometry
    Malkin, Robert
    Todd, Thomas
    Robert, Daniel
    JOURNAL OF SOUND AND VIBRATION, 2014, 333 (19) : 4473 - 4482
  • [10] Agreement of intracranial vessel diameters measured on 2D and 3D digital subtraction angiography using an automatic windowing algorithm
    Abe, Y.
    Yuki, I
    Otani, K.
    Shoji, T.
    Ishibashi, T.
    Murayama, Y.