Evaluation of Implant Stability Quotient of Sandblasted Acid-Etched (SAE) and Chemical-Modified SAE Dental Implants: A Clinical Study

被引:0
|
作者
Satpathy, Soumyadev [1 ]
Varalakshmi, Udutha [2 ]
Tenglikar, Pavan [3 ]
Chowdary, Koduru Ranga Roy [4 ]
Khader, Anas Abdul [5 ]
Parihar, Anuj Singh [6 ]
Kumar, Yashavanth D. S. [7 ]
Samanta, Anupa [8 ]
机构
[1] Fakir Mohan Med Coll & Hosp, Dept Dent, Balasore, Odisha, India
[2] Govt Dent Coll & Hosp, Dept Prosthodont, Vijayawada, Andhra Pradesh, India
[3] Komar Univ Sci & Technol, Coll Med, Dept Dent, Sulaymaniyah, Kurdistan Regio, Iraq
[4] Al Janah Med Complex, Ar Rass, Saudi Arabia
[5] Qassim Univ, Coll Dent Ar Rass, Dept Prevent Dent, Ar Rass, Saudi Arabia
[6] Peoples Dent Acad, Dept Periodontol, Bhopal, Madhya Pradesh, India
[7] Coll Dent Sci, Dept Oral & Maxillofacial Surg, Davanagere, Karnataka, India
[8] KIIT Deemed Univ, Kalinga Inst Dent Sci, Dept Oral Med & Radiol, Bhubaneswar, Odisha, India
关键词
Dental implant; osseointegration; stability; RESONANCE FREQUENCY-ANALYSIS;
D O I
10.4103/jpbs.jpbs_46_24
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives: The goal of the current research was to assess the implant stability quotient (ISQ) of dental implants that were chemically changed with SAE and without SAE. Materials and Methods: Patients in the current study had dental implants fitted with SAE (Group I) and chemically altered SAE (Group II). After implant implantation, resonance frequency analysis (RFA) was performed as soon as possible as well as one, three, six, nine, and twelve weeks later. Version 23.0 of SPSS Statistics for Windows was used to statistically analyze the results. Result: In SAE dental implants (Group I), a highest RFA value of 84.1 and a minimum value of 42.2 were noted. In chemically modified implants, the SAE (group II) mean RFA value ranged from 30.3 to 87.1. Conclusion: It has been noted that dental implants with surface treatment exhibit increased implant-bone osseointegration. Implants with hydrophilic surfaces osseointegrate more quickly than those with SAE areas.
引用
收藏
页码:S2075 / S2077
页数:3
相关论文
共 50 条
  • [31] Monitoring bone morphogenetic protein-2 and-7, soluble receptor activator of nuclear factor-κB ligand and osteoprotegerin levels in the peri-implant sulcular fluid during the osseointegration of hydrophilic-modified sandblasted acid-etched and sandblasted acid-etched surface dental implants
    Dolanmaz, D.
    Saglam, M.
    Inan, O.
    Dundar, N.
    Alniacik, G.
    Trak, B. Gursoy
    Kocak, E.
    Hakki, S. S.
    JOURNAL OF PERIODONTAL RESEARCH, 2015, 50 (01) : 62 - 73
  • [32] COMPARISON OF CLINICAL AND RADIOGRAPHIC PARAMETERS AMONG DENTAL IMPLANTS WITH SANDBLASTED ACID ETCHED AND ANODIZED SURFACE
    Rajasekar, Arvina
    Varghese, Sheeja S.
    INTERNATIONAL JOURNAL OF MEDICAL DENTISTRY, 2023, 27 (01) : 89 - 93
  • [33] Sandblasted and Acid Etched Titanium Dental Implant Surfaces Systematic Review and Confocal Microscopy Evaluation
    Cervino, Gabriele
    Fiorillo, Luca
    Iannello, Gaetano
    Santonocito, Dario
    Risitano, Giacomo
    Cicciu, Marco
    MATERIALS, 2019, 12 (11)
  • [34] Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible
    Cochran, DL
    Schenk, RK
    Lussi, A
    Higginbottom, FL
    Buser, D
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1998, 40 (01): : 1 - 11
  • [35] Histomorphometric evaluation of a dual acid-etched vs. a chemically modified hydrophilic dual acid-etched implant surface. An experimental study in dogs
    de Jesus, Rainde Naiara Rezende
    Stavropoulos, Andreas
    Fonseca Oliveira, Maiolino Thomaz
    Ferreira Soares, Priscilla Barbosa
    Gomes Moura, Camilla Christian
    Zanetta-Barbosa, Darceny
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (05) : 551 - 557
  • [36] Osseointegration and stability of a modified sand-blasted acid-etched implant: an experimental pilot study in sheep
    Abdel-Haq, Jawad
    Karabuda, Cuneyt Z.
    Arisan, Volkan
    Mutlu, Zihni
    Kurkcu, Mehmet
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (03) : 265 - 274
  • [37] Alterations in Surface Roughness and Chemical Characteristics of Sandblasted and Acid-Etched Titanium Implants after Irradiation with Different Diode Lasers
    Kim, Hak-Ki
    Park, Su-Yeon
    Son, Keunbada
    Kim, Yong-Gun
    Yu, Won-Jae
    Lee, Kyu-Bok
    Lee, Jae-Mok
    APPLIED SCIENCES-BASEL, 2020, 10 (12):
  • [38] A 5-Year Prospective Multicenter Study of Early Loaded Titanium Implants with a Sandblasted and Acid-Etched Surface
    Cochran, David L.
    Jackson, Jennifer M.
    Bernard, Jean-Pierre
    ten Bruggenkate, Christian M.
    Buser, Daniel
    Taylor, Thomas D.
    Weingart, Dieter
    Schoolfield, John D.
    Jones, Archie A.
    Oates, Thomas W., Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (06) : 1324 - 1343
  • [39] Interface shear strength of titanium implants with a sandblasted and acid-etched surface:: A biomechanical study in the maxilla of miniature pigs
    Buser, D
    Nydegger, T
    Oxland, T
    Cochran, DL
    Schenk, RK
    Hirt, HP
    Snétivy, D
    Nolte, LP
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1999, 45 (02): : 75 - 83
  • [40] Early Loading of Sandblasted and Acid-Etched Titanium Implants in the Edentulous Mandible: A Prospective 5-Year Study
    Lethaus, Bernd
    Kaelber, Joerg
    Petrin, Guido
    Brandstaetter, Anita
    Weingart, Dieter
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (04) : 887 - 892