Evaluation of Implant Stability Quotient of Sandblasted Acid-Etched (SAE) and Chemical-Modified SAE Dental Implants: A Clinical Study

被引:0
|
作者
Satpathy, Soumyadev [1 ]
Varalakshmi, Udutha [2 ]
Tenglikar, Pavan [3 ]
Chowdary, Koduru Ranga Roy [4 ]
Khader, Anas Abdul [5 ]
Parihar, Anuj Singh [6 ]
Kumar, Yashavanth D. S. [7 ]
Samanta, Anupa [8 ]
机构
[1] Fakir Mohan Med Coll & Hosp, Dept Dent, Balasore, Odisha, India
[2] Govt Dent Coll & Hosp, Dept Prosthodont, Vijayawada, Andhra Pradesh, India
[3] Komar Univ Sci & Technol, Coll Med, Dept Dent, Sulaymaniyah, Kurdistan Regio, Iraq
[4] Al Janah Med Complex, Ar Rass, Saudi Arabia
[5] Qassim Univ, Coll Dent Ar Rass, Dept Prevent Dent, Ar Rass, Saudi Arabia
[6] Peoples Dent Acad, Dept Periodontol, Bhopal, Madhya Pradesh, India
[7] Coll Dent Sci, Dept Oral & Maxillofacial Surg, Davanagere, Karnataka, India
[8] KIIT Deemed Univ, Kalinga Inst Dent Sci, Dept Oral Med & Radiol, Bhubaneswar, Odisha, India
关键词
Dental implant; osseointegration; stability; RESONANCE FREQUENCY-ANALYSIS;
D O I
10.4103/jpbs.jpbs_46_24
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives: The goal of the current research was to assess the implant stability quotient (ISQ) of dental implants that were chemically changed with SAE and without SAE. Materials and Methods: Patients in the current study had dental implants fitted with SAE (Group I) and chemically altered SAE (Group II). After implant implantation, resonance frequency analysis (RFA) was performed as soon as possible as well as one, three, six, nine, and twelve weeks later. Version 23.0 of SPSS Statistics for Windows was used to statistically analyze the results. Result: In SAE dental implants (Group I), a highest RFA value of 84.1 and a minimum value of 42.2 were noted. In chemically modified implants, the SAE (group II) mean RFA value ranged from 30.3 to 87.1. Conclusion: It has been noted that dental implants with surface treatment exhibit increased implant-bone osseointegration. Implants with hydrophilic surfaces osseointegrate more quickly than those with SAE areas.
引用
收藏
页码:S2075 / S2077
页数:3
相关论文
共 50 条
  • [1] A clinical and radiographic evaluation of resonance frequency analysis of sand blasted acid etched (sae) and chemical modified sae dental implants
    Kumary, T. P. Beena
    Parihar, Anuj Singh
    Mathew, Joe
    Sabu, Ipe K.
    Venkata, Sindhuja Kota
    Babaji, Prashant
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2019, 9 (01): : 55 - 59
  • [2] Sandblasted and acid-etched dental implants: A histologic study in rats
    Marinho, VC
    Celletti, R
    Bracchetti, G
    Petrone, G
    Minkin, C
    Piattelli, A
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (01) : 75 - 81
  • [3] Biomechanical comparison of the sandblasted and acid-etched and the machined and acid-etched titanium surface for dental implants
    Li, DH
    Ferguson, SJ
    Beutler, T
    Cochran, DL
    Sittig, C
    Hirt, HP
    Buser, D
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 60 (02): : 325 - 332
  • [4] Clinical trial on osseointegration using sandblasted or sandblasted and acid-etched implants
    Prosper, L
    Di Carlo, F
    Dodona, A
    Redaelli, S
    Quaranta, M
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B264 - B264
  • [5] Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface
    Barewal, RM
    Oates, TW
    Meredith, N
    Cochran, DL
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (05) : 641 - 651
  • [6] Comparison between Sandblasted Acid-Etched and Oxidized Titanium Dental Implants: In Vivo Study
    Velasco-Ortega, Eugenio
    Ortiz-Garcia, Ivan
    Jimenez-Guerra, Alvaro
    Monsalve-Guil, Loreto
    Munoz-Guzon, Fernando
    Perez, Roman A.
    Javier Gil, F.
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2019, 20 (13):
  • [7] Bone Response to Two Dental Implants with Different Sandblasted/Acid-Etched Implant Surfaces: A Histological and Histomorphometrical Study in Rabbits
    Scarano, Antonio
    Piattelli, Adriano
    Quaranta, Alesandro
    Lorusso, Felice
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [9] The long-term evaluation of the prognosis of implants with acid-etched surfaces sandblasted with alumina: a retrospective clinical study
    Kim, Min-Joong
    Yun, Pil-Young
    Chang, Na-Hee
    Kim, Young-Kyun
    MAXILLOFACIAL PLASTIC AND RECONSTRUCTIVE SURGERY, 2020, 42 (01)
  • [10] The long-term evaluation of the prognosis of implants with acid-etched surfaces sandblasted with alumina: a retrospective clinical study
    Min-Joong Kim
    Pil-Young Yun
    Na-Hee Chang
    Young-Kyun Kim
    Maxillofacial Plastic and Reconstructive Surgery, 42