A sourceless efficiency calibration model of airborne γ-spectrometry based on Geant4

被引:0
|
作者
Mei, Cong [1 ,2 ]
Fu, Chen [3 ]
Zhang, Wei [4 ]
Li, Jiangkun [4 ]
Liang, Xudong [3 ]
Wu, Xue [4 ]
Luo, Qibin [1 ]
Yang, Yaxin [1 ]
机构
[1] East China Univ Technol, State Key Lab Nucl Resources & Environm, Nanchang 330013, Peoples R China
[2] East China Univ Technol, Sch Nucl Sci & Engn, Nanchang 330013, Peoples R China
[3] East China Univ Technol, Sch Geophys & Measurement Control Technol, Nanchang 330013, Peoples R China
[4] Airborne Survey & Remote Sensing Ctr Nucl Ind, Shijiazhuang 050002, Peoples R China
关键词
Airborne gamma-spectrometry; Monte-carlo simulation; Geant4; code; Sourceless efficiency calibration; SYSTEM;
D O I
10.1016/j.net.2025.103594
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The calibration facility process for the airborne gamma-spectrometer, which is built at the Shijiazhuang Dagou Village Airport of China, is time-consuming and labor-intensive. In this paper, a sourceless efficiency calibration model based on the Monte Carlo method using the Geant4 software has been established. The proposed model allows for the acquisition of the gamma-spectrum response curve of the airborne gamma-spectrometer above a cylindrical gamma-radiation source containing uranium, thorium, and potassium elements in any proportion. It is applied to perform Compton scattering calibration and height attenuation correction for UGRS-10 airborne gamma spectrometer. The relative errors between the calibration parameters obtained by Geant4 simulation and those obtained by UGRS-10 airborne gamma spectrometer at Daguocun airport calibration facility are between 3 % and 27 %. The experiment demonstrates the Monte Carlo-based sourceless efficiency calibration model is suitable to calibrate airborne gamma-spectrometers and provides technical support for airborne gamma-spectrometry.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Development of a coupled simulation toolkit for computational radiation biology based on Geant4 and CompuCell3D
    Liu, Ruirui
    Higley, Kathryn A.
    Swat, Maciej H.
    Chaplain, Mark A. J.
    Powathil, Gibin
    Glazier, James A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (04)
  • [42] Comparison of Neutron Detection Performance of Four Thin-Film Semiconductor Neutron Detectors Based on Geant4
    Zhang, Zhongming
    Aspinall, Michael D.
    SENSORS, 2021, 21 (23)
  • [43] ANALYSING THE EFFECT OF A CRANIUM THICKNESS ON A BRAGG PEAK RANGE IN THE PROTON THERAPY: A TRIM AND GEANT4 BASED STUDY
    Ekinci, F.
    Bostanci, E.
    Guzel, M. S.
    Dagil, O.
    ST PETERSBURG POLYTECHNIC UNIVERSITY JOURNAL-PHYSICS AND MATHEMATICS, 2022, 15 (02): : 64 - 78
  • [44] Quantification of gold nanoparticle photon radiosensitization from direct and indirect effects using a complete human genome single cell model based on Geant4
    Zhao, Xiandong
    Liu, Ruirui
    Zhao, Tianyu
    Reynoso, Francisco J.
    MEDICAL PHYSICS, 2021, 48 (12) : 8127 - 8139
  • [45] Photo-neutron production of medical linear accelerator Elekta, precise model: A study with the Geant4 MC toolkit
    Farrag, Emad A. M.
    Wadi-Ramahi, Shada
    Hamad, Morad Kh.
    ANNALS OF NUCLEAR ENERGY, 2023, 194
  • [46] Simulation of p-type HPGe detector full-energy peak efficiency using GEANT4 Monte Carlo toolkit
    S. Penabeï
    D. Bongue
    A. B. Mistura
    P. Maleka
    K. M. Demdah
    G. N. M. Kwato
    International Journal of Environmental Science and Technology, 2024, 21 : 4509 - 4518
  • [47] Simulation of p-type HPGe detector full-energy peak efficiency using GEANT4 Monte Carlo toolkit
    Penabei, S.
    Bongue, D.
    Mistura, A. B.
    Maleka, P.
    Demdah, K. M.
    Kwato, G. N. M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2024, 21 (04) : 4509 - 4518
  • [48] Full modeling of AX-PET, a new PET device with axially oriented crystals, based on Geant4 and GATE
    Solevi, P.
    Oliver, J. F.
    Gillam, J.
    Rafecas, M.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [49] Commissioning of 6 MV medical linac for dynamic MLC-based IMRT on Monte Carlo code GEANT4
    Okamoto H.
    Fujita Y.
    Sakama K.
    Saitoh H.
    Kanai T.
    Itami J.
    Kohno T.
    Radiological Physics and Technology, 2014, 7 (2) : 246 - 253
  • [50] Voxel-based dose calculation of radionuclide imaging and therapy for preclinical studies using GEANT4 Monte Carlo simulation
    Liu, H.
    Geng, C.
    Tang, X.
    Tang, L.
    Li, X.
    Xu, P.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (02): : 317 - 322