A sourceless efficiency calibration model of airborne γ-spectrometry based on Geant4

被引:0
|
作者
Mei, Cong [1 ,2 ]
Fu, Chen [3 ]
Zhang, Wei [4 ]
Li, Jiangkun [4 ]
Liang, Xudong [3 ]
Wu, Xue [4 ]
Luo, Qibin [1 ]
Yang, Yaxin [1 ]
机构
[1] East China Univ Technol, State Key Lab Nucl Resources & Environm, Nanchang 330013, Peoples R China
[2] East China Univ Technol, Sch Nucl Sci & Engn, Nanchang 330013, Peoples R China
[3] East China Univ Technol, Sch Geophys & Measurement Control Technol, Nanchang 330013, Peoples R China
[4] Airborne Survey & Remote Sensing Ctr Nucl Ind, Shijiazhuang 050002, Peoples R China
关键词
Airborne gamma-spectrometry; Monte-carlo simulation; Geant4; code; Sourceless efficiency calibration; SYSTEM;
D O I
10.1016/j.net.2025.103594
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The calibration facility process for the airborne gamma-spectrometer, which is built at the Shijiazhuang Dagou Village Airport of China, is time-consuming and labor-intensive. In this paper, a sourceless efficiency calibration model based on the Monte Carlo method using the Geant4 software has been established. The proposed model allows for the acquisition of the gamma-spectrum response curve of the airborne gamma-spectrometer above a cylindrical gamma-radiation source containing uranium, thorium, and potassium elements in any proportion. It is applied to perform Compton scattering calibration and height attenuation correction for UGRS-10 airborne gamma spectrometer. The relative errors between the calibration parameters obtained by Geant4 simulation and those obtained by UGRS-10 airborne gamma spectrometer at Daguocun airport calibration facility are between 3 % and 27 %. The experiment demonstrates the Monte Carlo-based sourceless efficiency calibration model is suitable to calibrate airborne gamma-spectrometers and provides technical support for airborne gamma-spectrometry.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Gamma backscattering analysis of flaw types and orientation based on Monte Carlo GEANT4 simulations
    Wirawan, R.
    Angraini, L. M.
    Qomariyah, N.
    Waris, A.
    Djamal, M.
    APPLIED RADIATION AND ISOTOPES, 2020, 155
  • [32] Monte Carlo simulation of a PhosWatch detector using Geant4 for xenon isotope beta-gamma coincidence spectrum profile and detection efficiency calculations
    Mekarski, P.
    Zhang, W.
    Ungar, K.
    Bean, M.
    Korpach, E.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (10) : 1957 - 1963
  • [33] Scatter in an uncollimated x-ray CT machine based on a Geant4 Monte Carlo simulation
    Wadeson, Nicola
    Morton, Edward
    Lionheart, William
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [34] G4DARI: Geant4/GATE based Monte Carlo simulation interface for dosimetry calculation in radiotherapy
    Slimani, Faical A. A.
    Hamdi, Mahdjoub
    Bentourkia, M'hamed
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2018, 67 : 30 - 39
  • [35] A Geant4 based simulation platform of the HollandPTC R&D proton beamline for radiobiological studies
    Groenendijk, Celebrity F.
    Rovituso, Marta
    Lathouwers, Danny
    Brown, Jeremy M. C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 112
  • [36] Simulation of the multi-purpose gamma irradiator dose distribution based on the GEANT4 and GPU system
    Razimanesh, M.
    Hosseini, S. A.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (07)
  • [37] A GATE/Geant4 beam model for the MedAustron non-isocentric proton treatment plans quality assurance
    Elia, Alessio
    Resch, Andreas Franz
    Carlino, Antonio
    Boehlen, Till Tobias
    Fuchs, Hermann
    Palmans, Hugo
    Letellier, Virgile
    Dreindl, Ralf
    Osorio, Jhonnatan
    Stock, Markus
    Sarrut, David
    Grevillot, Loic
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 71 : 115 - 123
  • [38] A validated Geant4 model of a whole-body PET scanner with four-layer DOI detectors
    Ahmed, Abdella M.
    Chacon, Andrew
    Rutherford, Harley
    Akamatsu, Go
    Mohammadi, Akram
    Nishikido, Fumihiko
    Tashima, Hideaki
    Yoshida, Eiji
    Yamaya, Taiga
    Franklin, Daniel R.
    Rosenfeld, Anatoly
    Guatelli, Susanna
    Safavi-Naeini, Mitra
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
  • [39] New charge exchange model of GEANT4 for 9Be(p,n)9B reaction
    Shin, Jae Won
    Park, Tae-Sun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 342 : 194 - 199
  • [40] GEANT4 simulation of photo-peak efficiency of small high purity germanium detectors for nuclear power plant applications
    Rehman, Shakeel Ur
    Mirza, Sikander M.
    Mirza, Nasir M.
    Siddique, Muhammad Tariq
    ANNALS OF NUCLEAR ENERGY, 2011, 38 (01) : 112 - 117