Semi-Stationary Multisource AI-Powered Real-Time Tomography

被引:0
作者
Wu, Weiwen [1 ]
Tang, Yaohui [2 ]
Lv, Tianling [3 ]
Cong, Wenxiang [4 ]
Niu, Chuang [4 ]
Wang, Cheng [2 ]
Guo, Yiyan [2 ]
Chen, Peiqian [2 ]
Chang, Yunheng [3 ]
Wang, Ge [4 ]
Xi, Yan [3 ]
机构
[1] Sun Yat sen Univ, Sch Biomed Engn, Shenzhen 510275, Guangdong, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai 200052, Peoples R China
[3] Jiangsu First Imaging Med Equipment Co Ltd, Nantong 226000, Jiangsu, Peoples R China
[4] Rensselaer Polytech Inst, Dept Biomed Engn, Troy, NY 12180 USA
基金
中国国家自然科学基金; 美国国家卫生研究院;
关键词
Computed tomography; Imaging; Image reconstruction; X-ray imaging; Dictionaries; Tensors; Real-time systems; Cardiac imaging; computed tomography (CT); deep learning; image reconstruction; multisource; preclinical imaging; real time; ITERATIVE RECONSTRUCTION; IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; CT; ALGORITHM; QUALITY; SYSTEM;
D O I
10.1109/TRPMS.2024.3433575
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Over the past decades, the development of computed tomography (CT) technologies has been largely driven by the need for cardiac imaging but the temporal resolution remains insufficient for clinical CT in difficult cases and rather challenging for preclinical CT since small animals have much higher heart rates than humans. To address this challenge, here we report a semi-stationary multisource artificial intelligence (AI)-based real-time tomography (SMART) CT system. This unique scanner is featured by 29 source-detector pairs fixed on a circular track to collect X-ray signals in parallel, enabling instantaneous tomography in principle. Given the multisource architecture, the field of view covers only a cardiac region. To solve the interior problem, an AI-empowered interior tomography approach is developed to synergize sparsity-based regularization and learning-based reconstruction. To demonstrate the performance and utilities of the SMART system, extensive results are obtained in physical phantom experiments and animal studies, including dead and live rats as well as live rabbits. The reconstructed volumetric images convincingly demonstrate the merits of the SMART system using the AI-empowered interior tomography approach, enabling cardiac CT with the unprecedented temporal resolution of 33 ms, which enjoys the highest temporal resolution than the state of the art.
引用
收藏
页码:118 / 130
页数:13
相关论文
共 49 条
[1]   Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1964-1971
[2]   A multi-source inverse-geometry CT system: initial results with an 8 spot x-ray source array [J].
Baek, Jongduk ;
De Man, Bruno ;
Uribe, Jorge ;
Longtin, Randy ;
Harrison, Daniel ;
Reynolds, Joseph ;
Neculaes, Bogdan ;
Frutschy, Kristopher ;
Inzinna, Louis ;
Caiafa, Antonio ;
Senzig, Robert ;
Pelc, Norbert J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05) :1189-1202
[3]   Carbon nanotubes - the route toward applications [J].
Baughman, RH ;
Zakhidov, AA ;
de Heer, WA .
SCIENCE, 2002, 297 (5582) :787-792
[4]   Deep-learning cardiac motion analysis for human survival prediction [J].
Bello, Ghalib A. ;
Dawes, Timothy J. W. ;
Duan, Jinming ;
Biffi, Carlo ;
de Marvao, Antonio ;
Howard, Luke S. G. E. ;
Gibbs, J. Simon R. ;
Wilkins, Martin R. ;
Cook, Stuart A. ;
Rueckert, Daniel ;
O'Regan, Declan P. .
NATURE MACHINE INTELLIGENCE, 2019, 1 (02) :95-+
[5]  
Buzug TM, 2011, SPRINGER HANDBOOK OF MEDICAL TECHNOLOGY, P311
[6]   Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
MEDICAL PHYSICS, 2008, 35 (02) :660-663
[7]   A stationary computed tomography system with cylindrically distributed sources and detectors [J].
Chen, Yi ;
Xi, Yan ;
Zhao, Jun .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (06) :707-725
[8]   CT IMAGE RECONSTRUCTION ON A LOW DIMENSIONAL MANIFOLD [J].
Cong, Wenxiang ;
Wang, Ge ;
Yang, Qingsong ;
Li, Jia ;
Hsieh, Jiang ;
Lai, Rongjie .
INVERSE PROBLEMS AND IMAGING, 2019, 13 (03) :449-460
[9]  
Duan GF, 2012, INT C PATT RECOG, P493
[10]   X-ray scatter correction for multi- source interior computed tomography [J].
Gong, Hao ;
Yan, Hao ;
Jia, Xun ;
Li, Bin ;
Wang, Ge ;
Cao, Guohua .
MEDICAL PHYSICS, 2017, 44 (01) :71-83