Patterns of quality assurance and treatment planning for stereotactic body radiation therapy in India - A survey

被引:0
作者
Sharma, Smriti [1 ,2 ]
Upreti, Ritu Raj [2 ,3 ]
Kinhikar, Rajesh A. [2 ,3 ]
Sahani, G. [1 ]
Sharma, P. K. Dash [1 ]
机构
[1] Atom Energy Regulatory Board, Radiol Safety Div, Mumbai, Maharashtra, India
[2] Homi Bhabha Natl Inst, Mumbai, Maharashtra, India
[3] Tata Mem Hosp, Dept Med Phys, Mumbai, Maharashtra, India
关键词
Quality assurance; stereotactic body radiation therapy (SBRT); survey; treatment planning; RADIOTHERAPY;
D O I
10.4103/jcrt.jcrt_1090_23
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim:The use of stereotactic body radiation therapy (SBRT) is an increasing trend in the country. The aim of this study is to gain knowledge on patterns of quality assurance (QA) and treatment planning (TP) aspects with respect to SBRT.Materials and Methods:A questionnaire with multiple choice was designed to determine practices of SBRT covering areas such as years of experience, type of linear accelerator, tumor-motion strategies, calculation algorithm used in the TP system (TPS), the protocol used for small field dosimetry, the detector used for small field dosimetry and QA, respiratory management during delivery. The survey was sent to all radiotherapy institutes in the country having a minimum of one linear accelerator, and responses were analyzed.Results:From June 2022 to December 2022, 265 responses to the SBRT survey were received with response rate as 60.4%. The most common reason for not adopting SBRT was reported as a lack of capability of treatment machines to deliver SBRT (61.6%). Lung (81.1%) was the most practiced site. The most common delivery unit was a conventional linear accelerator (83%); 6 MV FFF (85.7%) was mostly used energy; volumetric-modulated arc radiotherapy (VMAT) (91.5%) was mostly used delivery technique; most of the equipment (more than 91.5%) used multileaf collimator (MLC) leaf width <= 5 mm. The most popular methods used for motion strategies during computed tomography (CT) were motion-encompassing and breath-hold techniques used by 65 (62.5%) and 62 (59.6%) respondents, respectively. The most popular method used for respiratory management during delivery was breath-hold by 55 (52.4%) respondents. Most TPS are equipped with either Type-C or Type-B algorithms. Heterogeneity was observed in the QA protocol and acceptance criteria for analysis of patient-specific QA.Conclusion:The survey resulted in heterogeneity in QA and TP aspects among users of SBRT and demands for harmonizing the dosimetric aspects of SBRT in the country.
引用
收藏
页码:1752 / 1758
页数:13
相关论文
共 14 条
  • [1] Rathod S, Munshi A, Agarwal JP., Practice of stereotactic body radiotherapy in a developing country: Perception, aspiration, and limitation‑A survey, Indian J Cancer, 53, pp. 135-137, (2016)
  • [2] Lewis S, Chopra S, Singh R, Engineer R., A survey of the practice of stereotactic body radiotherapy for hepatocellular and pancreatic malignancies in India, Indian J Cancer, 58, (2021)
  • [3] Solberg TD, Balter JM, Benedict SH, Fraass BA, Kavanagh B, Miyamoto C, Et al., Quality and safety considerations in stereotactic radiosurgery and stereotactic body radiation therapy: Executive summary, Pract Radiat Oncol, 2, pp. 2-9, (2012)
  • [4] Benedict SH, Yenice KM, Followill D, Galvin JM, Hinson W, Kavanagh B, Et al., Stereotactic body radiation therapy: The report of AAPM Task Group 101, Med Phys, 37, pp. 4078-4101, (2010)
  • [5] Marino C, Garibaldi C, Veronese I, Carbonini C, Russo S, Stasi M, Et al., A national survey on technology and quality assurance for stereotactic body radiation therapy, Phys Med, 65, pp. 6-14, (2019)
  • [6] Distefano G, Baker A, Scott AJ, Webster GJ, Survey of stereotactic ablative body radiotherapy in the UK by the QA group on behalf of the UK SABR Consortium, Br J Radiol, 87, (2014)
  • [7] Distefano G, Garikipati S, Grimes H, Hatton M., Current status of stereotactic ablative body radiotherapy in the UK: Six years of progress, BJR Open, 1, (2019)
  • [8] Pathak RS, Tibdewal A, Kinhikar R, Wakeham K, Akbarov K, Cordero L, Et al., Practice patterns and perspectives on stereotactic body radiation therapy for the metastatic spine from lower‑ and middle‑income countries, JCO Glob Oncol, 8, (2022)
  • [9] Dosimetry of Small Static Fields Used in External Beam Radiotherapy, (2017)
  • [10] Absorbed Dose Determination in External Beam Radiotherapy, (2000)