Precast structures are widely used in many parts of the world. This construction technique is more commonly preferred for low-rise industrial buildings than multi-story structures. The most commonly used column-beam connection in precast buildings is the dowel connection (DC). Past earthquakes in various parts of the world have shown that these connections do not provide sufficient resistance. The main deficiencies of such connections are that they are sheared or stripped due to the shear force demand from the in-plane effects of large earthquakes, and that they do not provide sufficient resistance to the overturning moments from the out-of-plane effects of the earthquakes. Correspondingly, many prefabricated buildings have collapsed during earthquakes, causing loss of life and property. This study proposes using post-tensioning tendon (PT) systems and systems created by adding steel springs (PTS) to eliminate the weaknesses in column-beam connections in precast structures. To this end, real-sized column and beam specimens used in precast buildings were produced, and experiments were conducted under the cyclic loads defined by the American Concrete Institute (ACI) Committee, Report 374, simulating earthquake effects for three different connection types (DC, PT, and PTS). It was observed that the proposed PTS connection type dissipated approximately one-third of the energy transferred to the joint through elastic deformation in the springs, compared to the DC and PT connection types. This indicates that the PTS specimens transferred significantly less energy to the column-beam connection region. Consequently, the PTS system exhibited much less damage in the column foundation and especially the column-beam connection areas than other test specimens. In conclusion, it can be stated that the use of the PTS connection type in prefabricated structures has high potential to reduce damages due to dynamic loads such as earthquakes.
引用
收藏
页数:17
相关论文
共 31 条
[1]  
[Anonymous], 2011, EN 197-1
[2]  
[Anonymous], 2024, TS EN 13369
[3]  
[Anonymous], 2005, ACI Committee 374
[4]  
[Anonymous], 2004, Eurocode 8: Design of structures for earthquake resistance - Part 1: General rules, seismic actions and rules for buildings, P1
[5]  
[Anonymous], 2020, Metallic MaterialsTensile TestingPart 1: Method of Test at Room Temperature
[6]  
[Anonymous], 2019, Eur. Comm. Stand. (CEN)
[7]  
[Anonymous], 2000, TS 500
[8]   Code-based damage assessment of existing precast industrial buildings following the February 6th, 2023 Kahramanmaraş earthquakes (Pazarcık Mw 7.7 and Elbistan Mw7.6) [J].
Arslan, Musa Hakan ;
Dere, Yunus ;
Ecemis, Ali Serdar ;
Dogan, Gamze ;
Ozturk, Murat ;
Korkmaz, Serra Zerrin .
JOURNAL OF BUILDING ENGINEERING, 2024, 86
[9]   Investigation of Precast Reinforced Concrete Structures during the 6 February 2023 Turkiye Earthquakes [J].
Avcil, Fatih .
SUSTAINABILITY, 2023, 15 (20)
[10]  
Chun SC, 2007, ACI STRUCT J, V104, P102