Reliability and validity of isokinetic and isometric strength testing: a systematic review

被引:0
|
作者
Knauer, Miriam [1 ]
Schroeder, Jan [2 ]
机构
[1] Univ Hamburg, Inst Bewegungswissensch, Hamburg, Germany
[2] Univ Hamburg, Inst Bewegungswissensch, Fak Erziehungswissensch Psychol & Bewegungswissens, Arbeitsbereich Sport & Bewegungsmed, Turmweg 2, D-20148 Hamburg, Germany
关键词
strength testing; peak force; peak torque; reproducibility; test economy; TEST-RETEST RELIABILITY; EXTENSOR; ABSOLUTE; FLEXOR;
D O I
10.1055/a-2439-4094
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective Isometric muscle strength testing is easier to apply, but isokinetic test results are deemed to offer a better transfer for training purposes. This systematic review aims to elucidate differences in terms of validity and reliability, if any, between isometric and isokinetic approaches. Material and Methods In January 2024, the PubMed database was searched for studies reporting reliability or validity measures for healthy adults for both isokinetic and isometric strength testing devices. Investigations of certain handheld types of dynamometers or publications older than 30 years were excluded. Results Thirteen studies met the inclusion criteria. Isometric maximal strength testing tended to demonstrate higher short-term reliability coefficients (ICC: 0.87-0.96) compared to isokinetic approaches (ICC: 0.69-0.99), while absolute measures for reproducibility were somehow similar for isometric (CV: 6.9-9.4%, SEM: 4.5-11.0%) and isokinetic testing (CV: 2.3-12.4%,SEM: 4.8-14.0%). Validity was confirmed for both isometric and isokinetic testing, but correlation coefficients varied markedly depending on the external criteria (EMG r>0.9, 5-10-RM r>0.8, Cross Sectional Area r>0.7, specific isokinetic comparisons r>0.5). Conclusions Confirming general validity for both, existing evidence suggests negligible advantages for isometric compared to isokinetic devices in terms of reproducibility measures. Future research should address comparisons seeking for side-effect properties of novel isometric and isokinetic devices such as accessibility of normative data for certain populations or time economy.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Test-retest reliability of isometric mid-thigh pull maximum strength assessment: a systematic review
    Grgic, Jozo
    Scapec, Bela
    Mikulic, Pavle
    Pedisic, Zeljko
    BIOLOGY OF SPORT, 2022, 39 (02) : 407 - 414
  • [22] Reliability of dynamic and isometric upper muscle strength testing in breast cancer survivors
    Santos, Wanderson
    Marques, Vitor
    de Lira, Claudio Andre B.
    Martins, Wagner
    Vieira, Amilton
    Mani, Diba
    Battaglini, Claudio
    Vieira, Carlos
    PEERJ, 2024, 12
  • [23] RELIABILITY OF REPEATED ISOMETRIC NECK STRENGTH AND ENDURANCE TESTING IN A SIMULATED CONTACT POSTURE
    Salmon, Danielle M.
    Handcock, Phil J.
    Sullivan, S. John
    Rehrer, Nancy J.
    Niven, Brian E.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2015, 29 (03) : 637 - 646
  • [24] Reliability and Validity of a Novel Isokinetic Knee Dynamometer System
    Riemann, Bryan L.
    Watson, Matthew D.
    Davies, George J.
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2021, 23 (04) : 107 - 116
  • [25] Inter-machine reliability of the Biodex and Cybex isokinetic dynamometers for knee flexor/extensor isometric, concentric and eccentric tests
    de Araujo Ribeiro Alvares, Joao Breno
    Rodrigues, Rodrigo
    Franke, Rodrigo de Azevedo
    Cordeiro da Silva, Bruna Goncalves
    Pinto, Ronei Silveira
    Vaz, Marco Aurelio
    Baroni, Bruno Manfredini
    PHYSICAL THERAPY IN SPORT, 2015, 16 (01) : 59 - 65
  • [26] Reliability of isokinetic trunk muscle strength measurement
    Karatas, GK
    Gögüs, F
    Meray, J
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2002, 81 (02) : 79 - 85
  • [27] Reliability of isokinetic and isometric knee-extensor force in older women
    Symons, TB
    Vandervoort, AA
    Rice, CL
    Overend, TJ
    Marsh, GD
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2004, 12 (04) : 525 - 537
  • [28] The reliability of electromechanical delay and torque during isometric and concentric isokinetic contractions
    Howatson, Glyn
    Glaister, Mark
    Brouner, James
    van Someren, Ken A.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2009, 19 (05) : 975 - 979
  • [29] The reliability, variability and minimal detectable change of multiplanar isometric trunk strength testing using a fixed digital dynamometer
    Bucke, Jonathan
    Mattiussi, Adam
    May, Karen
    Shaw, Joseph
    JOURNAL OF SPORTS SCIENCES, 2024, 42 (09) : 840 - 846
  • [30] Validity of Isometric Muscle Strength Measurements of the Lower Limbs Using a Hand-held Dynamometer and Belt: a Comparison with an Isokinetic Dynamometer
    Katoh, Munenori
    Hiiragi, Yukinobu
    Uchida, Manabu
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2011, 23 (04) : 553 - 557