Evaluation of the effect of attachments on torque control of palatally positioned maxillary lateral teeth with clear aligners: Finite element analysis

被引:2
作者
Karsli, Nurver [1 ]
Ocak, Irmak [2 ]
Gokcek, Sevil [1 ]
Ozsoy, Omur Polat
机构
[1] Karadeniz Tech Univ, Dept Orthodont, Hastane Caddesi 13-A, TR-61080 Trabzon, Turkiye
[2] Hacettepe Univ, Dept Orthodont, Ankara, Turkiye
关键词
Clear aligners; Lateral incisor; Torque; Finite element analysis; MOVEMENT; INCISOR;
D O I
10.4041/kjod24.029
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The effect of different attachment positions on torque control during the labialization of maxillary lateral incisors with clear aligners was evaluated using finite element analysis. Methods: Anatomical data acquired through cone-beam computed tomography, combined with the design of 0.625-mm- thick aligners and horizontal attachments, were integrated into the software. Six distinct simulations were generated: (1) attachment-free, (2) labial attachment placed gingivally, (3) labial attachment placed mid-crown, (4) labial attachment placed incisally, (5) palatal attachment, and (6) attachment placed labially and palatally. The evaluation was performed using a default aligner activation of 0.25 mm. Results: The crown of the lateral incisor demonstrated labial movement, while the root exhibited palatal movement in all models. Group 6 showed the lowest crown and root displacements on both axes, whereas the attachment- free group exhibited the greatest crown movement. The aligner experienced maximum deformation at the incisal edge, with deformation progressively decreasing towards the gingival region. Group 6 demonstrated the least deformation of all groups. The Von Mises stresses in the periodontal ligament (PDL) were most pronounced at the gingival level, with higher values on the palatal side than on the labial side. Conclusions: The use of attachments, particularly the combination of labial and palatal attachments, enables a more precise labialization process, helping to reduce tipping. Increasing crown movement of the lateral incisor elevates stress within the PDL, with the highest stress observed in the palatal region at the gingival level.
引用
收藏
页码:58 / 68
页数:11
相关论文
共 35 条
[1]  
Ahmed T, 2023, J OROFAC ORTHOP, V84, P178, DOI 10.1007/s00056-021-00374-3
[2]  
Barone Sandro, 2016, BIOSTEC 2016. 9th International Joint Conference on Biomedical Engineering Systems and Technologies. Proceedings: Bioimaging, P44
[3]   Torque movement of the upper anterior teeth using a clear aligner in cases of extraction: a finite element study [J].
Cheng, Yuxun ;
Gao, Jie ;
Fang, Shishu ;
Wang, Wei ;
Ma, Yanning ;
Jin, Zuolin .
PROGRESS IN ORTHODONTICS, 2022, 23 (01)
[4]  
Comba Benedetta, 2017, J Clin Orthod, V51, P24
[5]   Clear aligner orthodontic therapy of rotated mandibular round-shaped teeth: A finite element study [J].
Cortona, Andrea ;
Rossini, Gabriele ;
Parrini, Simone ;
Deregibus, Andrea ;
Castroflorio, Tommaso .
ANGLE ORTHODONTIST, 2020, 90 (02) :247-254
[6]  
Costa Rafael, 2020, Dental Press J. Orthod., V25, P46
[7]   Evaluation of Tooth Movement Accuracy with Aligners: A Prospective Study [J].
D'Anto, Vincenzo ;
Bucci, Rosaria ;
De Simone, Vincenzo ;
Ghislanzoni, Luis Huanca ;
Michelotti, Ambrosina ;
Rongo, Roberto .
MATERIALS, 2022, 15 (07)
[8]   Effects of variable attachment shapes and aligner material on aligner retention [J].
Dasy, Hiltrud ;
Dasy, Andreas ;
Asatrian, Greg ;
Rozsa, Noemi ;
Lee, Hao-Fu ;
Kwak, Jin Hee .
ANGLE ORTHODONTIST, 2015, 85 (06) :934-940
[9]   Torquing an upper central incisor with aligners-acting forces and biomechanical principles [J].
Hahn, Wolfram ;
Zapf, Antonia ;
Dathe, Henning ;
Fialka-Fricke, Julia ;
Fricke-Zech, Susanne ;
Gruber, Rudolf ;
Kubein-Meesenburg, Dietmar ;
Sadat-Khonsari, Reza .
EUROPEAN JOURNAL OF ORTHODONTICS, 2010, 32 (06) :607-613
[10]   Clear aligners generations and orthodontic tooth movement [J].
Hennessy, Joe ;
Al-Awadhi, Ebrahim A. .
JOURNAL OF ORTHODONTICS, 2016, 43 (01) :68-76