Spectral Content Effects Study in Non-Contact Resonance Ultrasound Spectroscopy

被引:0
作者
Tayyib, Muhammad [1 ]
Svilainis, Linas [1 ]
机构
[1] Kaunas Univ Technol, Dept Elect Engn, LT-51368 Kaunas, Lithuania
关键词
air-coupled ultrasound; spread-spectrum signals; spectral losses compensation; resonance ultrasound spectroscopy; EXCITATION; POSITION; LEVEL; WIDTH;
D O I
10.3390/s25010265
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of spread-spectrum signals (arbitrary pulse width and position (APWP) sequences) in air-coupled resonant ultrasound spectroscopy is studied. It was hypothesized that spread-spectrum signal optimization should be based on te signal to noise ratio (SNR). Six APWP signal optimization criteria were proposed for this purpose. Experimental measurements were conducted using a thin polycarbonate sample using two standard spread-spectrum signals, linear and nonlinear frequency modulation, together with six optimized APWP signals. It was found that the performance of APWP signals derived from linear frequency modulation was better. The two best performing optimization criteria are SNR improvement on a linear scale with the SNR as an additional weight and energy improvement on a dB scale. The influence of spectral coverage on measurement errors was evaluated. It was found that it is sufficient to cover the sample resonance peak and the valley. The lowest error rates for density, 3%, and for thickness, 3.5%, were achieved when the upper valley was covered. For velocity, the best result, 5%, was achieved when the lower valley was covered. The lowest error rate for attenuation, 3.8%, was achieved in the case when both valleys were covered. Yet no significant performance degradation was noted when a whole -30 dB passband was covered.
引用
收藏
页数:14
相关论文
共 30 条
[1]   Resonant ultrasound spectroscopy: The essential toolbox [J].
Balakirev, Fedor F. ;
Ennaceur, Susan M. ;
Migliori, Robert J. ;
Maiorov, Boris ;
Migliori, Albert .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (12)
[2]   Broadband Air-Coupled Ultrasound Emitter and Receiver Enable Simultaneous Measurement of Thickness and Speed of Sound in Solids [J].
Bente, Klaas ;
Rus, Janez ;
Mooshofer, Hubert ;
Gaal, Mate ;
Grosse, Christian Ulrich .
SENSORS, 2023, 23 (03)
[3]   Nonlinear/linear resonance ultrasound spectroscopy (N/RUS) of additively manufactured 316L stainless steel samples using in-contact and non-contact excitation [J].
Bozek, Evan ;
Williams, Colin L. ;
Riviere, Jacques ;
Shokouhi, Parisa .
NDT & E INTERNATIONAL, 2023, 140
[4]  
Brekhovskikh L., 1990, ACOUSTICS LAYERED ME
[5]   Nonlinear frequency modulated excitation signal and modified compressing filter for improved range resolution and side lobe level of ultrasound echoes [J].
Dantas, T. M. ;
Costa-Felix, R. P. B. ;
Machado, J. C. .
APPLIED ACOUSTICS, 2018, 130 :238-246
[6]   Instantaneous and non-destructive relative water content estimation from deep learning applied to resonant ultrasonic spectra of plant leaves [J].
Dolores Farinas, Maria ;
Jimenez-Carretero, Daniel ;
Sancho-Knapik, Domingo ;
Javier Peguero-Pina, Jose ;
Gil-Pelegrin, Eustaquio ;
Gomez Alvarez-Arenas, Tomas .
PLANT METHODS, 2019, 15 (01)
[7]  
Farinas L., 2023, P IEEE INT ULTR S MO, DOI [10.1109/IUS51837.2023.10307535, DOI 10.1109/IUS51837.2023.10307535]
[8]   Use of air-coupled ultrasound for the non-invasive characterization of the textural properties of pork burger patties [J].
Farinas, Lola ;
Contreras, Marina ;
Sanchez-Jimenez, Virginia ;
Benedito, Jose ;
Garcia-Perez, Jose, V .
JOURNAL OF FOOD ENGINEERING, 2021, 297
[9]   CHIRP EXCITATION OF ULTRASONIC PROBES AND ALGORITHM FOR FILTERING TRANSIT TIMES IN HIGH-RANGEABILITY GAS-FLOW METERING [J].
FOLKESTAD, T ;
MYLVAGANAM, KS .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1993, 40 (03) :193-215
[10]  
Gomez Alvarez-Arenas Tomas, 2009, 2009 IEEE International Ultrasonics Symposium, P771, DOI 10.1109/ULTSYM.2009.5441754