A Simple Single-Ended Post-Fault Location Technique for DC Lines Based on Controlled Re-Energizations

被引:1
|
作者
Mahtani, Kumar [1 ]
Guerrero, Jose M. [2 ]
Decroix, Julien [3 ]
Platero, Carlos A. [1 ]
机构
[1] Univ Politecn Madrid, Escuela Tecn Super Ingn Ind, Dept Automat Elect & Elect Engn & Ind Informat, Madrid 28006, Spain
[2] Univ Basque Country, Escuela Ingn Bilbao, Dept Elect Engn, Bilbao 48013, Spain
[3] Paris Saclay Univ, Interdisciplinary Res Grp Energy Modeling, F-91190 Gif Sur Yvette, France
来源
ELECTRONICS | 2025年 / 14卷 / 02期
关键词
DC lines; fault location; inductance; injection; impedance; medium-voltage direct current; reclosing; single-ended; time constant; PULSE INJECTION; SHORT-CIRCUIT; MMC; IDENTIFICATION; SUBMODULE;
D O I
10.3390/electronics14020275
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Fault location in medium-voltage direct current (MVDC) systems is an essential yet underexplored area compared to high-voltage (HVDC) and low-voltage (LVDC) systems. MVDC systems, characterized by intermediate line lengths and fault resistances, as well as rapid fault clearance requirements, demand specialized solutions. This paper proposes a novel single-ended, offline fault location method based on controlled re-energizations after fault clearance. This approach employs a switched grounding resistor and a bypass connection through the current-limiting inductor to extract fault parameters from the discharge curves of two re-energization cycles. By analyzing the time constants derived from these curves, the method estimates fault location and resistance with high accuracy. The proposed method eliminates the need for additional active injection sources and circuit breaker modifications, ensuring seamless integration into existing MVDC infrastructure. Furthermore, the method avoids inter-terminal communication delays and sampling delays before fault clearance. Validation through electromagnetic transient simulations demonstrates fault location errors below 5% for fault resistances up to 50 Omega. Results show that the method performs better for faults farther from the active terminal, with the higher errors seen for short distances and elevated resistances. The proposed technique offers a robust and practical solution for post-fault location in DC lines.
引用
收藏
页数:25
相关论文
共 48 条
  • [31] Single-Ended Fault Location for Hybrid Feeders Based on Characteristic Distribution of Traveling Wave Along a Line
    Shu, Hongchun
    Liu, Xuhan
    Tian, Xincui
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (01) : 339 - 350
  • [32] A physics-informed data-driven fault location method for transmission lines using single-ended measurements with field data validation
    Zou, Xinchen
    Xing, Yiqi
    Lu, Dayou
    He, Xuming
    Liu, Yu
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 236
  • [33] Generalized instance-based fault locating in transmission lines using single-ended voltage measurements
    Farshad, Mohammad
    Sadeh, Javad
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (05): : 799 - 816
  • [34] Single-ended line fault location method for multi-terminal HVDC system based on optimized variational mode decomposition
    Huai, Qing
    Liu, Kaipei
    Hooshyar, Ali
    Ding, Hua
    Chen, Kun
    Liang, Qin
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 194
  • [35] A Single-Ended Fault Location Method for Transmission Line Based on Full Waveform Features Extractions of Traveling Waves
    Deng, Feng
    Zhong, Yihan
    Zeng, Zhe
    Zu, Yarui
    Zhang, Zhen
    Huang, Yifei
    Feng, Sixu
    Zeng, Xiangjun
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (04) : 2585 - 2595
  • [36] Single-Ended Fault Location Method Based on Wavelet Theory: Application to a Double-Circuit Transmission Line
    Xie, F.
    Haddad, A.
    Griffiths, H.
    2013 48TH INTERNATIONAL UNIVERSITIES' POWER ENGINEERING CONFERENCE (UPEC), 2013,
  • [37] A single-ended traveling wave based fault location method using DWT in hybrid parallel HVAC/HVDC overhead transmission lines on the same tower
    Fayazi, Mohammad
    Joorabian, Mahmood
    Saffarian, Alireza
    Monadi, Mehdi
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 220
  • [38] Fault Detection and Location of 35 kV Single-Ended Radial Distribution Network Based on Traveling Wave Detection Method
    Xu, Xiaowei
    Zhou, Fangrong
    Nie, Yongjie
    Xu, Wenhua
    Wang, Ke
    Ouyang, Jian
    Zhou, Kaihong
    Chen, Shan
    Han, Yiming
    PROCESSES, 2023, 11 (08)
  • [39] Correlation-based single-ended traveling wave fault location methods: A key settings parametric sensitivity analysis
    Reis, Raphael L. A.
    Lopes, Felipe V.
    ELECTRIC POWER SYSTEMS RESEARCH, 2022, 213
  • [40] A traveling wave natural frequency-based single-ended fault location method with unknown equivalent system impedance
    He, Zhengyou
    Li, Xiaopeng
    Chen, Shuang
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2016, 26 (03): : 509 - 524