Effect of different airway devices on ventilation during cardiopulmonary resuscitation

被引:0
作者
Segond, N. [1 ,2 ,3 ]
Fischer, M. [1 ,2 ]
Fontecave-Jallon, J. [3 ]
Podsiadlo, P. [4 ]
Lurie, K. [5 ,6 ]
Bellier, A. [7 ]
Debaty, G. [1 ,2 ,3 ]
机构
[1] Univ Hosp Grenoble Alpes, Emergency Dept, Grenoble, France
[2] Univ Hosp Grenoble Alpes, Mobile Intens Care Unit, Grenoble, France
[3] Univ Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup,Grenoble INP,TIMC, F-38000 Grenoble, France
[4] Jan Kochanowski Univ, Dept Emergency Med, Kielce, Poland
[5] Hennepin Healthcare, Minneapolis, MN USA
[6] Univ Minnesota, Minneapolis, MN USA
[7] Univ Grenoble Alpes, Dept Anat LADAF, Grenoble, France
关键词
Cardiopulmonary resuscitation; Heart arrest; Mechanical ventilation; Respiratory physiology; Respiratory mechanics; HOSPITAL CARDIAC-ARREST; CEREBRAL PERFUSION-PRESSURE; BAG-MASK VENTILATION; ENDOTRACHEAL INTUBATION; MECHANICAL VENTILATION; LARYNGEAL TUBE; HEAD; GUIDELINES; COUNCIL; STRATEGY;
D O I
10.1016/j.resuscitation.2025.110584
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: This study compared face mask, supraglottic airway device (SGA), and endotracheal tube (ETT) ventilation with mechanical ventilation (MV) during cardiopulmonary resuscitation (CPR) in the flat position and with head and thorax elevation (HTE). Methods: Using thawed, fresh-frozen human cadavers this randomized cross-over study compared face mask, SGA, and ETT ventilation using an automated ventilator in the flat and HTE positions. Tidal volume (TV) was set to 8 mL/kg ideal predicted body weight, and expiratory TV (VTe) (mL/ kg) was the primary endpoint. Secondary endpoints included inspiratory TV (VTi), maximal inspiratory airway pressure (Pmax), and leakage between inspiratory and expiratory tidal volumes (VTi-VTe). Results: Data from 8 cadavers and 2302 ventilation cycles were analyzed. In the flat position, VTe was 7.66 +/- 3.75 with ETT, 5.01 +/- 3.14 with SGA, and 5.63 +/- 2.83 with face mask, respectively. A mixed linear model showed the airway device significantly impacted VTe, VTi, Pmax, and VTi-VTe (p < 0.001 for each). Compared with intubation, both face mask and SGA ventilation resulted in lower VTe, lower Pmax, and higher VTi-VTe (p < 0.001 for each). No significant differences were observed between face mask and SGA ventilation. There were higher VTe and lower VTiVTe values (p < 0.001 for each) with HTE versus the flat position (p < 0.001). Conclusions: In human cadavers undergoing CPR, mechanical ventilation through a face mask or SGA versus an ETT was associated with lower VTe, lower Pmax, and higher leakage values in human cadavers during CPR. Head and thorax elevation reduce face mask and SGA airway leakage during CPR and increase VTe.
引用
收藏
页数:8
相关论文
共 36 条
  • [21] Consistent head up cardiopulmonary resuscitation haemodynamics are observed across porcine and human cadaver translational models
    Moore, Johanna C.
    Holley, Joe
    Segal, Nicolas
    Lick, Michael C.
    Labarere, Jose
    Frascone, Ralph J.
    Dodd, Kenneth W.
    Robinson, Aaron E.
    Lick, Charles
    Klein, Lauren
    Ashton, Andrew
    McArthur, Angela
    Tsangaris, Adamantios
    Makaretz, Anna
    Makaretz, Mike
    Debaty, Guillaume
    Pepe, Paul E.
    Lurie, Keith G.
    [J]. RESUSCITATION, 2018, 132 : 133 - 139
  • [22] A review of ventilation in adult out-of-hospital cardiac arrest
    Neth, Matthew R.
    Idris, Ahamed
    McMullan, Jason
    Benoit, Justin L.
    Daya, Mohamud R.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF EMERGENCY PHYSICIANS OPEN, 2020, 1 (03) : 190 - 201
  • [23] Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR
    Orlob, Simon
    Wittig, Johannes
    Hobisch, Christoph
    Auinger, Daniel
    Honnef, Gabriel
    Fellinger, Tobias
    Ristl, Robin
    Schindler, Otmar
    Metnitz, Philipp
    Feigl, Georg
    Prause, Gerhard
    [J]. SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2021, 29 (01)
  • [24] Mechanical Ventilation Management During Mechanical Chest Compressions
    Orso, Daniele
    Vetrugno, Luigi
    Federici, Nicola
    Borselli, Matteo
    Spadaro, Savino
    Cammarota, Gianmaria
    Bove, Tiziana
    [J]. RESPIRATORY CARE, 2021, 66 (02) : 334 - 346
  • [25] Recommended guidelines for monitoring, reporting, and conducting research on medical emergency team, outreach, and rapid response systems: An Utstein-style scientific statement: A scientific statement from the international liaison committee on resuscitation (American Heart Association, Australian Resuscitation Council, European Resuscitation Council, Heart and Stroke Foundation of Canada, InterAmerican Heart Foundation, Resuscitation Council of Southern Africa, and the New Zealand Resuscitation Council); the American Heart Association emergency cardiovascular care committee; the council on cardiopulmonary, perioperative, and critical care; and the interdisciplinary working group on quality of care and outcomes research
    Peberdy, Mary Ann
    Cretikos, Michelle
    Abella, Benjamin S.
    DeVita, Michael
    Goldhill, David
    Kloeck, Walter
    Kronick, Steven L.
    Morrison, Laurie J.
    Nadkarni, Vinay M.
    Nichol, Graham
    Nolan, Jerry P.
    Parr, Michael
    Tibballs, James
    van der Jagt, Elise W.
    Young, Lis
    [J]. CIRCULATION, 2007, 116 (21) : 2481 - 2500
  • [26] Effect of controlled sequential elevation timing of the head and thorax during cardiopulmonary resuscitation on cerebral perfusion pressures in a porcine model of cardiac arrest
    Rojas-Salvador, Carolina
    Moore, Johanna C.
    Salverda, Bayert
    Lick, Michael
    Debaty, Guillaume
    Lurie, Keith G.
    [J]. RESUSCITATION, 2020, 149 : 162 - 169
  • [27] The Effect of Head Up Cardiopulmonary Resuscitation on Cerebral and Systemic Hemodynamics
    Ryu, Hyun Ho
    Moore, Johanna C.
    Yannopoulos, Demetris
    Lick, Michael
    McKnite, Scott
    Shin, Sang Do
    Kim, Tae Yun
    Metzger, Anja
    Rees, Jennifer
    Tsangaris, Adamantios
    Debaty, Guillaume
    Lurie, Keith G.
    [J]. RESUSCITATION, 2016, 102 : 29 - 34
  • [28] Mechanical ventilation during cardiopulmonary resuscitation: influence of positive end-expiratory pressure and head-torso elevation
    Segond, N.
    Terzi, N.
    Duhem, H.
    Bellier, A.
    Aygalin, M.
    Fuste, L.
    Viglino, D.
    Fontecave-Jallon, J.
    Lurie, K.
    Guerin, C.
    Debaty, G.
    [J]. RESUSCITATION, 2023, 185
  • [29] Supraglottic Airway Device to Improve Ventilation Success and Reduce Pulmonary Aspiration during Cardio-Pulmonary Resuscitation by Basic Life Support Rescuers: A Randomized Cross-over Human Cadaver Study
    Segond, N.
    Bellier, A.
    Duhem, H.
    Sanchez, C.
    Busi, O.
    Deutsch, S.
    Aguilera, L.
    Truan, D.
    Koch, F. X.
    Viglino, D.
    Debaty, G.
    [J]. PREHOSPITAL EMERGENCY CARE, 2023, 27 (05) : 695 - 703
  • [30] Mechanical Ventilation During CPR The Emergence of Clinical Evidence
    Segond, Nicolas
    Debaty, Guillaume
    [J]. CHEST, 2024, 166 (02) : 243 - 244