Column face bending in anchored blind-bolted connections to concrete filled hollow sections

被引:0
|
作者
Mahmood, Mohammed [1 ]
Tizani, Walid [2 ]
机构
[1] Univ Diyala, Dept Civil Engn, Baqubah, Iraq
[2] Univ Nottingham, Dept Civil Engn, Nottingham, England
关键词
Anchored bolted connection; Bolt pitch distance; Bolt gauge distance; Anchored length; Column face bending; Concrete filled tubular columns; BEHAVIOR; PERFORMANCE; STRENGTH; BEAM;
D O I
10.1016/j.jcsr.2024.109120
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research investigates the bending behaviour of the column face component of concrete filled tubular columns connected to other structural members via Extended HolloBolt (EHB). The effect of bolt gauge and pitch distances and anchored length were investigated by experimental tests and finite element analysis. Totally, eighteen specimens were tested and 31 finite element models were analysed. Results showed that, the concrete acts compositely with the anchored bolts until it fails by forming a cone shape starting from the anchored nut and extending to the concrete surface. The cone radius at the concrete surface is equal to 0.82 times the anchorage length. The contribution of the anchored bolts in the component plastic strength can be quantified by considering the work required to initiate concrete cracking across the cone projection on the column face. The component initial stiffness seems to be influenced significantly by the bolt gauge and anchorage length. The use of small bolt pitch or bolt gauge limits the advantage of anchoring the EHB in the concrete and the large bolt gauges result in minor yield in the column walls (g >= 85 % of the column face width). A Major enhancement in the component strength can be achieved by increasing the bolt anchorage length to more than six times the internal bolt diameter (db).
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Thermal behaviour of blind-bolted connections to hollow and concrete-filled steel tubular columns
    Pascual, Ana M.
    Romero, Manuel L.
    Tizani, Walid
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 107 : 137 - 149
  • [2] Fire performance of blind-bolted connections to concrete filled tubular columns in tension
    Pascual, Ana M.
    Romero, Manuel L.
    Tizani, Walid
    ENGINEERING STRUCTURES, 2015, 96 : 111 - 125
  • [3] Experimental evaluation and component model for single anchored blind-bolted concrete filled tube connections under direct tension
    Debnath, Partha Pratim
    Chan, Tak-Ming
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
  • [4] Numerical Behaviour of Blind-Bolted Beam Connections to Square Hollow Sections with Different Infills
    Gunes, Sahin
    Theofanous, Marios
    Skalomenos, Konstantinos
    Baniotopoulos, Charalampos
    ce/papers, 2023, 6 (3-4) : 1338 - 1343
  • [5] Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns
    Goldsworthy, H. M.
    Gardner, A. P.
    STRUCTURAL ENGINEERING AND MECHANICS, 2006, 24 (04) : 463 - 478
  • [6] Anchored blind bolted composite connection to a concrete filled steel tubular column
    Agheshlui, Hossein
    Goldsworthy, Helen
    Gad, Emad
    Mirza, Olivia
    STEEL AND COMPOSITE STRUCTURES, 2017, 23 (01): : 115 - 130
  • [7] Tensile behaviour of anchored blind bolts in concrete filled square hollow sections
    Hossein Agheshlui
    Helen Goldsworthy
    Emad Gad
    Saman Fernando
    Materials and Structures, 2016, 49 : 1511 - 1525
  • [8] Nonlinear finite element analysis of anchored blind-bolted joints to concrete-filled steel tubular columns
    Wang Y.
    Wang Z.
    Pan J.
    Wang P.
    International Journal of Performability Engineering, 2019, 15 (02): : 676 - 687
  • [9] Tensile behaviour of anchored blind bolts in concrete filled square hollow sections
    Agheshlui, Hossein
    Goldsworthy, Helen
    Gad, Emad
    Fernando, Saman
    MATERIALS AND STRUCTURES, 2016, 49 (04) : 1511 - 1525
  • [10] Seismic response investigation on CFDST column to steel beam blind-bolted connections
    Wang, Jingfeng
    Guo, Lei
    Guo, Xiang
    Ding, Zhaodong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 161 : 137 - 153