Evaluation and Comparison of Accuracy of Complete Arch Digital and Conventional Implant Impression as Influenced by the Use of a 3D Printed Modular Splint -An In-Vitro Study

被引:0
|
作者
Pol, Bhushan S. [1 ]
Sabane, Ajay V. [1 ]
Jadhav, Rajashree D. [1 ]
Kadam, Pankaj P. [1 ]
Gachake, Arti R. [1 ]
Kalsekar, Bhagyashree G. [1 ]
机构
[1] Bharati Vidyapeeth Deemed Univ, Dent Coll & Hosp, Dept Prosthodont Crown & Bridge, Pune, Maharashtra, India
关键词
Digital impression; implant impression; intraoral scanner;
D O I
10.4103/jpbs.jpbs_1256_24
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Aim:To investigate the accuracy of Complete Arch implant impression digitally and conventionally with and without using a 3D printed modular chain splint. Methods:The STROBE (strengthening the reporting of observational studies in epidemiology) guidelines were use to conduct an analytical cross-sectional study. The total number of samples (n = 40) was derived and was divided into two groups with four subgroups: A1-Digital Impression without splinting of scan bodies (reference scan) and A2-Digital Impression splinted with 3D printed Modular Chain splint (test scan) and B1-Conventional Impression without Splinting of impression copings (reference scan) and B2- Conventional Impression splinted with 3D printed modular chain splint (test scan). In total 40 sample STL files were superimposed. Each analogue were assessed with respect to X, Y and Z axes (X-longitudinal, Y-lateral, and Z-vertical). All the data analysis was performed with SPSS version 22.0 with P < 0.05 as statistical significance. Results:There was no significant difference in the mean standard deviation along the X-axis (P > 0.05). The mean standard deviation along with a Y-axis (P > 0.05) also showed no statistical difference whereas along with the Z-axis mean standard deviation (P > 0.05). Along the vertical Z-axis, there was a significant difference in the mean standard deviation in comparison with the horizontal X and Y axes. Conclusions:There is no significant difference in accuracy of complete arch implant impression when the intraoral digital impression was compared to the traditional impression with or without the use of 3D printed modular splint.
引用
收藏
页码:S3764 / S3767
页数:4
相关论文
共 39 条
  • [1] Conventional and digital complete arch implant impression techniques: An in vitro study comparing accuracy
    Gomez-Polo, Miguel
    Sallorenzo, Alessandro
    Cascos, Rocio
    Ballesteros, Juan
    Barmak, Abdul B.
    Revilla-Leon, Marta
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (04): : 809 - 818
  • [2] Digital workflow: In vitro accuracy of 3D printed casts generated from complete-arch digital implant scans
    Papaspyridakos, Panos
    Chen, Yo-Wei
    Alshawaf, Bahaa
    Kang, Kiho
    Finkelman, Matthew
    Chronopoulos, Vasilios
    Weber, Hans-Peter
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (05): : 589 - 593
  • [3] Accuracy of complete-arch digital implant impression with or without scanbody splinting: An in vitro study
    Pozzi, Alessandro
    Arcuri, Lorenzo
    Lio, Fabrizio
    Papa, Andrea
    Nardi, Alessandra
    Londono, Jimmy
    JOURNAL OF DENTISTRY, 2022, 119
  • [4] Comparison between stereophotogrammetric, digital, and conventional impression techniques in implant-supported fixed complete arch prostheses: An in vitro study
    Tohme, Hani
    Lawand, Ghida
    Chmielewska, Maja
    Makhzoume, Joseph
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (02): : 354 - 362
  • [5] Chairside 3-D printed impression trays: a new approach to increase the accuracy of conventional implant impression taking? An in vitro study
    Alexander Schmidt
    Cara Berschin
    Bernd Wöstmann
    Maximiliane Amelie Schlenz
    International Journal of Implant Dentistry, 9
  • [6] Chairside 3-D printed impression trays: a new approach to increase the accuracy of conventional implant impression taking? An in vitro study
    Schmidt, Alexander
    Berschin, Cara
    Woestmann, Bernd
    Schlenz, Maximiliane Amelie
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)
  • [7] Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study
    Pozzi, Alessandro
    Agliardi, Enrico
    Lio, Fabrizio
    Nagy, Katalin
    Nardi, Alessandra
    Arcuri, Lorenzo
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 172 - 180
  • [8] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Ma, Bowen
    Yue, Xinxin
    Sun, Yujie
    Peng, Lingyan
    Geng, Wei
    BMC ORAL HEALTH, 2021, 21 (01)
  • [9] Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
    Bowen Ma
    Xinxin Yue
    Yujie Sun
    Lingyan Peng
    Wei Geng
    BMC Oral Health, 21
  • [10] Digital workflow: In vitro accuracy of 3D printed casts generated from complete-arch digital implant scans (vol 124, pg 589, 2020)
    Papaspyridakos, P.
    Chen, Y-W
    Alshawaf, B.
    Kang, K.
    Finkelman, M.
    Chronopoulos, V
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 129 (06):