Magnetic Resonance Imaging Monitoring of Thermal Lesions Produced by Focused Ultrasound

被引:0
|
作者
Antoniou, Anastasia [1 ]
Evripidou, Nikolas [1 ]
Nikolaou, Anastasia [1 ]
Georgiou, Andreas [1 ]
Giannakou, Marinos [1 ]
Chrysanthou, Antreas [2 ]
Georgiou, Leonidas [2 ]
Ioannides, Cleanthis [2 ]
Damianou, Christakis [1 ]
机构
[1] Cyprus Univ Technol, Dept Elect Engn Comp Engn & Informat, 30 Archbishop Kyprianou St, CY-3036 Limassol, Cyprus
[2] German Oncol Ctr, Dept Intervent Radiol, Limassol, Cyprus
关键词
Contrast; lesion; monitoring; magnetic resonance imaging; porcine; ultrasound; NONENHANCED MRI; IN-VIVO; ABLATION; CONTRAST; SURGERY;
D O I
10.4103/jmu.jmu_112_23
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background:The main goal of the study was to find the magnetic resonance imaging (MRI) parameters that optimize contrast between tissue and thermal lesions produced by focused ultrasound (FUS) using T1-weighted (T1-W) and T2-weighted (T2-W) fast spin echo (FSE) sequences.Methods:FUS sonications were performed in ex vivo porcine tissue using a single-element FUS transducer of 2.6 MHz in 1.5 and 3 T MRI scanners. The difference in relaxation times as well as the impact of critical MRI parameters on the resultant contrast-to-noise ratio (CNR) between coagulated and normal tissues were assessed. Discrete and overlapping lesions were inflicted in tissue with simultaneous acquisition of T2-W FSE images.Results:FUS lesions are characterized by lower relaxation times than intact porcine tissue. CNR values above 80 were sufficient for proper lesion visualization. For T1-W imaging, repetition time values close to 1500 ms were considered optimum for obtaining sufficiently high CNR at the minimum time cost. Echo time values close to 50 ms offered the maximum lesion contrast in T2-W FSE imaging. Monitoring of acute FUS lesions during grid sonications was performed successfully. Lesions appeared as hypointense spots with excellent contrast from surrounding tissue.Conclusion:MRI monitoring of signal intensity changes during FUS sonication in grid patterns using optimized sequence parameters can provide useful information about lesion progression and the success of ablation. This preliminary study demonstrated the feasibility of the proposed monitoring method in ex vivo porcine tissue and should be supported by in vivo studies to assess its clinical potential.
引用
收藏
页码:297 / 308
页数:12
相关论文
共 50 条
  • [31] Achilles tendon xanthoma imaging on ultrasound and magnetic resonance imaging
    Fernandes, Eloy de Avila
    Sena Santos, Eduardo Henrique
    de Mello Tucunduva, Tatiana Cardoso
    Ferrari, Antonio J. L.
    Correa Fernandes, Artur da Rocha
    REVISTA BRASILEIRA DE REUMATOLOGIA, 2015, 55 (03) : 313 - 316
  • [32] In Vivo Feasibility of Real-Time Monitoring of Focused Ultrasound Surgery (FUS) Using Harmonic Motion Imaging (HMI)
    Maleke, Caroline
    Konofagou, Elisa E.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (01) : 7 - 11
  • [33] The Emerging Role of Magnetic Resonance Imaging-Guided Focused Ultrasound in Functional Neurosurgery
    Fiani, Brian
    Lissak, India A.
    Soula, Marisol
    Sarhadi, Kasra
    Shaikh, Emad Salman
    Baig, Aqsa
    Farooqui, Mudassir
    Quadri, Syed A.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (08)
  • [34] Magnetic Resonance Imaging-Guided Focused Laser Interstitial Thermal Therapy for Intracranial Lesions: Single-Institution Series
    Hawasli, Ammar H.
    Bagade, Swapnil
    Shimony, Joshua S.
    Miller-Thomas, Michelle
    Leuthardt, Eric C.
    NEUROSURGERY, 2013, 73 (06) : 1007 - 1017
  • [35] Evaluation of high intensity focused ultrasound treatment for different types of adenomyosis based on magnetic resonance imaging classification
    Gong, Chunmei
    Wang, Yangyang
    Lv, Fajin
    Zhang, Lian
    Wang, Zhibiao
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2022, 39 (01) : 530 - 538
  • [36] Stem Cell Labeling with Superparamagnetic Iron Oxide Nanoparticles Using Focused Ultrasound and Magnetic Resonance Imaging Tracking
    Le, Hulong
    Nan, Xiang
    Wang, Zhiyong
    Gao, Lin
    Xie, Lisi
    Zou, Chao
    Wan, Qian
    Pan, Di
    Beauchamp, Norman
    Yang, Xiaoming
    Matula, Thomas
    Qiu, Bensheng
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2015, 15 (04) : 2605 - 2612
  • [37] Magnetic Resonance Imaging-guided Focused Ultrasound Surgery in a Swine Adenomyosis Model
    Zhang, Qi
    Chen, Ye
    Lai, Mao
    Li, Yajie
    Li, Qing
    Fu, Caixia
    Yao, Zhenwei
    Zhang, Junhai
    ACADEMIC RADIOLOGY, 2023, 30 : S220 - S226
  • [38] Principles and technique of Magnetic Resonance Guided Focused Ultrasound Surgery (MRgFUS) in the treatment of uterine fibroids
    Vazquez-Lamadrid, Jorge
    Fernandez-de Lara, Yeni
    Carrasco-Choque, Analuz
    Romero-Trejo, Cecilia
    Cosme-Labarthe, Juan
    Roldan-Valadez, Ernesto
    GACETA MEDICA DE MEXICO, 2011, 147 (04): : 333 - 341
  • [39] Renal ablation using magnetic resonance-guided high intensity focused ultrasound: Magnetic resonance imaging and histopathology assessment
    Saeed, Maythem
    Krug, Roland
    Do, Loi
    Hetts, Steven W.
    Wilson, Mark W.
    WORLD JOURNAL OF RADIOLOGY, 2016, 8 (03): : 298 - 307
  • [40] Magnetic resonance imaging for intratesticular and extratesticular scrotal lesions
    Woldrich, Jeffrey M.
    Im, Ronald D.
    Hughes-Cassidy, Fiona M.
    Aganovic, Lejla
    Sakamoto, Kyoko
    CANADIAN JOURNAL OF UROLOGY, 2013, 20 (04) : 6855 - 6859