Nanoparticle Contrast Agents for Dark-Field X-ray Imaging

被引:0
|
作者
Navarrete-Leon, Carlos [1 ,2 ]
Doherty, Adam [1 ,2 ]
Strimaite, Margarita [3 ,4 ]
Bear, Joseph C. [5 ]
Olivo, Alessandro [1 ]
Endrizzi, Marco [1 ,2 ]
Patrick, P. Stephen [3 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, London WC1E 6BT, England
[2] Francis Crick Inst, X Ray Microscopy & Tomog Lab, London NW1, England
[3] UCL, Ctr Adv Biomed Imaging, Div Med, London WC1E 6DD, England
[4] UCL, Fac Life Sci, UCL Sch Pharm, London WC1N 1AX, England
[5] Kingston Univ, Sch Life Sci Pharm & Chem, Penrhyn Rd, Kingston Upon Thames KT1 2EE, England
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
X-ray; Biomaterials; Dark-Field; ContrastAgents; Nanoparticles; IN-VIVO; MICROBUBBLES; MEDIA; CT;
D O I
10.1021/acs.nanolett.4c04878
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The poor soft tissue contrast of X-ray CT necessitates contrast agent use to improve diagnosis across disease applications, yet their poor detection sensitivity requires high injected doses, which restrict use in at-risk populations. Dark-field X-ray imaging is emerging as a more sensitive alternative to traditional attenuation-based imaging, leveraging scattered radiation to produce contrast. Yet aside from large, short-lived microbubbles, the alternate physics of dark-field detection has yet to be exploited for contrast agent development. Here we demonstrate that high-Z nanoparticles can provide a new means to producing dark-field image contrast, promoting scatter via a higher rather than lower electron density compared to microbubbles, increasing detection sensitivity compared to attenuation-based detection of a clinical iodine-based agent at an equivalent X-ray dose. As the use of dark-field X-ray imaging expands into more common clinical usage, this will support the development of a new class of nanoparticulate contrast agents.
引用
收藏
页码:1036 / 1042
页数:7
相关论文
共 50 条
  • [21] Gold nanoparticles as contrast agents in x-ray imaging and computed tomography
    Cole, Lisa E.
    Ross, Ryan D.
    Tilley, Jennifer M. R.
    Vargo-Gogola, Tracy
    Roeder, Ryan K.
    NANOMEDICINE, 2015, 10 (02) : 321 - 341
  • [22] Optimization of in vivo murine X-ray dark-field computed tomography
    Umkehrer, Stephan
    Birnbacher, Lorenz
    Burkhardt, Rico
    von Teuffenbach, Maximilian
    Yildirim, Ali Onder
    Pfeiffer, Daniela
    Herzen, Julia
    Pfeiffer, Franz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (10)
  • [23] Contrast agents for preclinical targeted X-ray imaging
    Li, Xiang
    Anton, Nicolas
    Zuber, Guy
    Vandamme, Thierry
    ADVANCED DRUG DELIVERY REVIEWS, 2014, 76 : 116 - 133
  • [24] A first investigation of accuracy, precision and sensitivity of phase-based x-ray dark-field imaging
    Astolfo, Alberto
    Endrizzi, Marco
    Kallon, Gibril
    Millard, Thomas P.
    Vittoria, Fabio A.
    Olivo, Alessandro
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2016, 49 (48)
  • [25] Ex Vivo Perfusion-Simulation Measurements of Microbubbles as a Scattering Contrast Agent for Grating-Based X-Ray Dark-Field Imaging
    Velroyen, Astrid
    Bech, Martin
    Tapfer, Arne
    Yaroshenko, Andre
    Mueller, Mark
    Paprottka, Philipp
    Ingrisch, Michael
    Cyran, Clemens C.
    Auweter, Sigrid D.
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Pfeiffer, Franz
    PLOS ONE, 2015, 10 (07):
  • [26] X-ray Dark-field Radiography - In -Vivo Diagnosis of Lung Cancer in Mice
    Scherer, Kai
    Yaroshenko, Andre
    Boeluekbas, Deniz Ali
    Gromann, Lukas B.
    Hellbach, Katharina
    Meinel, Felix G.
    Braunagel, Margarita
    von Berg, Jens
    Eickelberg, Oliver
    Reiser, Maximilian F.
    Pfeiffer, Franz
    Meiners, Silke
    Herzen, Julia
    SCIENTIFIC REPORTS, 2017, 7
  • [27] Discrimination analysis of breast calcifications using x-ray dark-field radiography
    Rauch, Thomas
    Rieger, Jens
    Pelzer, Georg
    Horn, Florian
    Erber, Ramona
    Wunderle, Marius
    Emons, Julius
    Nabieva, Naiba
    Fuhrich, Nicole
    Michel, Thilo
    Hartmann, Arndt
    Fasching, Peter A.
    Anton, Gisela
    MEDICAL PHYSICS, 2020, 47 (04) : 1813 - 1826
  • [28] X-ray dark-field computed tomography using a grating interferometer setup
    Bevins, Nicholas
    Zambelli, Joseph
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [29] Recent advances in ytterbium-based contrast agents for in vivo X-ray computed tomography imaging: promises and prospects
    Liu, Yanlan
    Liu, Jianhua
    Ai, Kelong
    Yuan, Qinghai
    Lu, Lehui
    CONTRAST MEDIA & MOLECULAR IMAGING, 2014, 9 (01) : 26 - 36
  • [30] Renally Excretable Silver Telluride Nanoparticles as Contrast Agents for X-ray Imaging
    Nieves, Lenitza M.
    Dong, Yuxi C.
    Rosario-Berrios, Derick N.
    Mossburg, Katherine
    Hsu, Jessica C.
    Cramer, Gwendolyn M.
    Busch, Theresa M.
    Maidment, Andrew D. A.
    Cormode, David P.
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (30) : 34354 - 34364