Investigation of hemodynamic bulk flow patterns caused by aortic stenosis using a combined 4D Flow MRI-CFD framework

被引:0
|
作者
Wang, Tianai [1 ]
Quast, Christine [2 ]
Boenner, Florian [2 ]
Kelm, Malte [2 ,3 ]
Zeus, Tobias [2 ]
Lemainque, Teresa [4 ]
Steinseifer, Ulrich [1 ]
Neidlin, Michael [1 ]
机构
[1] Rhein Westfal TH Aachen, Inst Appl Med Engn, Med Fac, Dept Cardiovasc Engn, Aachen, Germany
[2] Heinrich Heine Univ, Dept Cardiol Pulm Dis & Vasc Med, Dusseldorf, Germany
[3] Heinrich Heine Univ, Cardiovasc Res Inst Dusseldorf, CARID, Dusseldorf, Germany
[4] Rhein Westfal TH Aachen, Med Fac, Dept Diagnost & Intervent Radiol, Aachen, Germany
关键词
COMPUTATIONAL FLUID-DYNAMICS; WALL SHEAR-STRESS; CAROTID BIFURCATION; VELOCITY; RECONSTRUCTION;
D O I
10.1371/journal.pcbi.1012467
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Aortic stenosis (AS) leads to alterations of supra-valvular flow patterns which can cause increased damage of red blood cell (RBC) membranes. We investigated these patient specific patterns of a severe AS patient and their reversal in healthy flow through a 4D Flow MRI-based CFD methodology. Computational models of subject-specific aortic geometries were created using in-vivo medical imaging data. Temporally and spatially resolved boundary conditions derived from 4D Flow MRI were implemented for an AS patient and a healthy subject. After validation of the in-silico results with in-vivo data, a healthy inflow profile was set for the AS patient in the CFD model. Pathological versus healthy flow fields were compared regarding their blood flow characteristics, i.e., shear stresses on RBCs and helicity. The accuracy of the 4D Flow MRI-based CFD model was proven with excellent agreement between in-vivo and in-silico velocity fields and R-2 = 0.9. A pathological high shear stress region in the bulk flow was present during late systole with an increase of 125% compared to both healthy flow. The physiological bihelical structure with predominantly right-handed helices vanished for the pathological state. Instead, a left-handed helix appeared, accompanied by an overall increase in turbulent kinetic energy in areas of accumulated left-handed helicity. The validated 4D Flow MRI-based CFD model identified marked differences between AS and healthy flow. It suggests that altered turbulent and helical structures in the bulk flow are the cause for increased, potentially damaging forces acting upon RBCs in AS.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] The Role of Imaging of Flow Patterns by 4D Flow MRI in Aortic Stenosis
    Garcia, Julio
    Barker, Alex J.
    Markl, Michael
    JACC-CARDIOVASCULAR IMAGING, 2019, 12 (02) : 252 - 266
  • [2] Aortic Flow Patterns and Peak Velocity Assessment Using 4D Flow MRI in Dilated Ascending Aorta With and Without Aortic Valve Stenosis and Regurgitation
    Suwa, Kenichiro
    Rahman, Ozair A.
    Bollache, Emilie
    Rose, Michael J.
    Rahsepar, Amir A.
    Hayashi, Hideharu
    Carr, James
    Collins, Jeremy
    Barker, Alex
    Markl, Michael
    CIRCULATION, 2016, 134
  • [3] 4D Flow MRI in Ascending Aortic Aneurysms: Reproducibility of Hemodynamic Parameters
    Juffermans, Joe F.
    van Assen, Hans C.
    te Kiefte, Bastiaan J. C.
    Ramaekers, Mitch J. F. G.
    van der Palen, Roel L. F.
    van den Boogaard, Pieter
    Adriaans, Bouke P.
    Wildberger, Joachim E.
    Dekkers, Ilona A.
    Scholte, Arthur J. H. A.
    Schalla, Simon
    Lamb, Hildo J.
    Westenberg, Jos J. M.
    APPLIED SCIENCES-BASEL, 2022, 12 (08):
  • [4] Assessment of Intracranial Atherosclerotic Stenosis Using 4D Flow MRI Derived Hemodynamic Biomarkers.
    Vali, Alireza
    Aristova, Maria
    Vakil, Parmede
    Abdalla, Ramez
    Ansari, Sameer
    Prabhakaran, Shyam
    Markl, Michael
    Schnell, Susanne
    STROKE, 2019, 50
  • [5] Patient Specific Hemodynamics: Combined 4D Flow-Sensitive MRI and CFD
    Stalder, A. F.
    Liu, Z.
    Hennig, J.
    Korvink, J. G.
    Li, K. C.
    Markl, M.
    COMPUTATIONAL BIOMECHANICS FOR MEDICINE: SOFT TISSUES AND THE MUSCULOSKELETAL SYSTEM, 2011, : 27 - 38
  • [6] 4D Flow MRI Applications for Aortic Disease
    Burris, Nicholas S.
    Hope, Michael D.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (01) : 15 - +
  • [7] 4D Flow MRI and CFD Simulations of Pulsatile Flow in a Phantom Model of Arterial Stenosis: Visualizing the Vortex Dynamics
    Kazemi, Amirkhosro
    Nath, Ruponti
    Negahdar, Mj
    Stoddard, Marcus
    Amini, Amir A.
    MEDICAL IMAGING 2021: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2021, 11600
  • [8] Automated hemodynamic assessment for cranial 4D flow MRI
    Roberts, Grant S.
    Hoffman, Carson A.
    Rivera-Rivera, Leonardo A.
    Berman, Sara E.
    Eisenmenger, Laura B.
    Wieben, Oliver
    MAGNETIC RESONANCE IMAGING, 2023, 97 : 46 - 55
  • [9] 4D flow MRI hemodynamic biomarkers for cerebrovascular diseases
    Wahlin, Anders
    Eklund, Anders
    Malm, Jan
    JOURNAL OF INTERNAL MEDICINE, 2022, 291 (02) : 115 - 127
  • [10] Creating Hemodynamic Atlases of Cardiac 4D Flow MRI
    Cibis, Merih
    Bustamante, Mariana
    Eriksson, Jonatan
    Carlhall, Carl-Johan
    Ebbers, Tino
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (05) : 1389 - 1399