Non-uniform Fourier transform based image classification in single-particle Cryo-EM

被引:0
作者
Bai, Zijian [1 ]
Huang, Jian [1 ]
机构
[1] Univ Coll Cork, Room 1-57,First Floor,Western Gateway Bldg,Western, Cork T12 XF62, Ireland
来源
JOURNAL OF STRUCTURAL BIOLOGY-X | 2025年 / 11卷
关键词
Non-uniform Fourier transform; 2D classification; Rotation-invariant feature extraction; Single-particle Cryo-EM; ELECTRON; RECONSTRUCTION; SUITE;
D O I
10.1016/j.yjsbx.2025.100121
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In the single-particle Cryo-EM projection image classification, it is a common practice to apply the Fourier transform to the images and extract rotation-invariant features in the frequency domain. However, this process involves interpolation, which can reduce the accuracy of the results. In contrast, the non-uniform Fourier transform provides more direct and accurate computation of rotation-invariant features without the need for interpolation in the computation process. Leveraging the capabilities of the non-uniform discrete Fourier transform (NUDFT), we have developed an algorithm for the rotation-invariant classification. To highlight its potential and applicability in the field of single-particle Cryo-EM, we conducted a direct comparison with the traditional Fourier transform and other methods, demonstrating the superior performance of the NUDFT.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A Fast and Effective Microfluidic Spraying-Plunging Method for High-Resolution Single-Particle Cryo-EM
    Feng, Xiangsong
    Fu, Ziao
    Kaledhonkar, Sandip
    Jia, Yuan
    Shah, Binita
    Jin, Amy
    Liu, Zheng
    Sun, Ming
    Chen, Bo
    Grassucci, Robert A.
    Ren, Yukun
    Jiang, Hongyuan
    Frank, Joachim
    Lin, Qiao
    [J]. STRUCTURE, 2017, 25 (04) : 663 - +
  • [32] Could Egg White Lysozyme be Solved by Single Particle Cryo-EM?
    Zhang, Y.
    Tammaro, R.
    Peters, P. J.
    Ravelli, R. B. G.
    [J]. JOURNAL OF CHEMICAL INFORMATION AND MODELING, 2020, 60 (05) : 2605 - 2613
  • [33] Application of the non-uniform Fourier transform to non-uniformly sampled Fourier transform spectrometers
    Wen, Muqian
    Houlihan, John
    [J]. OPTICS COMMUNICATIONS, 2023, 540
  • [34] Reducing bias and variance for CTF estimation in single particle cryo-EM
    Heimowitz, Ayelet
    Anden, Joakim
    Singer, Amit
    [J]. ULTRAMICROSCOPY, 2020, 212
  • [35] Identification of incorrectly oriented particles in cryo-EM single particle analysis
    Mendez, Jeison
    Garduno, Edgar
    Maria Carazo, Jose
    Sorzano, Carlos Oscar S.
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2021, 213 (03)
  • [36] Non-Uniform Sparse Fourier Transform and Its Applications
    Wei, Deyun
    Yang, Jun
    [J]. IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2022, 70 : 4468 - 4482
  • [37] Accurate modeling of single-particle cryo-EM images quantitates the benefits expected from using Zernike phase contrast
    Hall, R. J.
    Nogales, E.
    Glaeser, R. M.
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2011, 174 (03) : 468 - 475
  • [38] How low can we go? Structure determination of small biological complexes using single-particle cryo-EM
    Wu, Mengyu
    Lander, Gabriel C.
    [J]. CURRENT OPINION IN STRUCTURAL BIOLOGY, 2020, 64 : 9 - 16
  • [39] Retrieving high-resolution information from disordered 2D crystals by single-particle cryo-EM
    Righetto, Ricardo D.
    Biyani, Nikhil
    Kowal, Julia
    Chami, Mohamed
    Stahlberg, Henning
    [J]. NATURE COMMUNICATIONS, 2019, 10 (1)
  • [40] Using the Volta phase plate with defocus for cryo-EM single particle analysis
    Danev, Radostin
    Tegunov, Dimitry
    Baumeister, Wolfgang
    [J]. ELIFE, 2017, 6