An electric field and runtime driven band model for high-speed, real-time imaging gel electrophoresis

被引:0
作者
Luo, Kan [1 ,2 ]
Chen, Yu [2 ,3 ]
Liang, Chaobing [1 ,2 ]
Zhang, Qirong [1 ,2 ]
Huang, Jing [1 ,2 ]
Wang, Wu [4 ]
Yang, Lina [5 ]
机构
[1] Fujian Univ Technol, Sch Elect Elect Engn & Phys, Fuzhou 350118, Peoples R China
[2] Fuzhou Ind Integrat Automat Technol Innovat Ctr, Fuzhou 350118, Peoples R China
[3] Fujian Univ Technol, Sch Mech & Automot Engn, Fuzhou 350118, Peoples R China
[4] FuZhou Univ, Coll Elect Engn & Automat, Fuzhou 350108, Peoples R China
[5] Minjiang Univ, Fuzhou Inst Oceanog, Marine & Agr Biotechnol Lab, Fuzhou 350108, Peoples R China
关键词
Gel electrophoresis (GE); Band model; Band dispersion; Joule heat; Real-time imaging; Nucleic acid separation; OPTIMIZATION; SEPARATION; MOBILITY; STRENGTH; SYSTEM; LAW;
D O I
10.1016/j.aca.2025.343873
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Traditional temperature-dependent models face difficulties in compact systems due to complex temperature control. This study introduces an electric field strength and runtime driven (E-t) band model to improve GE performance by correlating band behavior with electric field and runtime rather than temperature. Results: We developed a compact E-t model based GE system, which equipped with inert platinum-titanium electrodes, a quartz-glass-embedded tank for passive cooling, and smartphone-based real-time fluorescence imaging. Experimental results from real-time tracking of GE bands, model fitting under different E-t conditions, and the separation of rice receptor protein kinase genes (CERK1 and CEBiP) confirmed that the proposed model can accurately describe electrophoretic band migration and dispersion, while maintaining good agreement with traditional temperature-based models and being little affected by temperature. Furthermore, successful nucleic acid separation was achieved within minutes under a high electric field strength in our system. Significance: By minimizing the reliance on temperature control mechanisms, the E-t band model offers a new perspective for the design of analytical chemistry instruments, enabling electrophoresis to focus primarily on optimizing the two key parameters, E and t. In addition, our portable, real-time imaging GE system enhances separation efficiency and provides a practical, high-performance reference solution for rapid, on-site analysis applications.
引用
收藏
页数:11
相关论文
共 45 条
[21]  
Malik S. C., 1992, Mathematical Analysis
[22]   Recent developments of point-of-care (POC) testing platform for biomolecules [J].
Manmana, Yanawut ;
Kubo, Takuya ;
Otsuka, Koji .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 135 (135)
[23]   Optimization of a microfluidic electrophoretic immunoassay using a Peltier cooler [J].
Mukhitov, Nikita ;
Yi, Lian ;
Schrell, Adrian M. ;
Roper, Michael G. .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1367 :154-160
[24]   Controlling Dispersion during Single-Cell Polyacrylamide-Gel Electrophoresis in Open Microfluidic Devices [J].
Pan, Qiong ;
Yamauchi, Kevin A. ;
Herr, Amy E. .
ANALYTICAL CHEMISTRY, 2018, 90 (22) :13419-13426
[25]   Design and computational analysis of a novel Azurin-BR2 chimeric protein against breast cancer [J].
Rehman, Hafiz Muhammad ;
Yousaf, Numan ;
Hina, Syeda Mahlaqa ;
Nadeem, Tariq ;
Ansari, Mushtaq Ahmad ;
Chaudry, Afeefa ;
Kafait, Iram ;
Khalid, Sania ;
Alanzi, Abdullah R. ;
Bashir, Hamid .
TOXICOLOGY RESEARCH, 2024, 13 (06)
[26]   Enhanced electrophoretic separation of proteins by tethered SiO2 nanoparticles in an SDS-polyacrylamide gel network [J].
Sajjadi, Sayyed Hashem ;
Ahmadzadeh, Hossein ;
Goharshadi, Elaheh K. .
ANALYST, 2020, 145 (02) :415-423
[27]   Heat dissipation in slab gel electrophoresis: The effect of embedded TiO2 nanoparticles on the thermal profiles [J].
Sajjadi, Sayyed Hashem ;
Goharshadi, Elaheh K. ;
Ahmadzadeh, Hossein .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1118 :63-69
[28]   PolyJet-Based 3D Printing against Micromolds to Produce Channel Structures for Microchip Electrophoresis [J].
Selemani, Major A. ;
Castiaux, Andre D. ;
Martin, R. Scott .
ACS OMEGA, 2022, 7 (15) :13362-13370
[29]   Numerical simulation of Joule heating effect on sample band transport in capillary electrophoresis [J].
Tang, GY ;
Yang, C ;
Gong, HQ ;
Chai, JC ;
Lam, YC .
ANALYTICA CHIMICA ACTA, 2006, 561 (1-2) :138-149
[30]   Smart phone-powered capillary electrophoresis on a chip for foodborne bacteria detection [J].
Van Dan Nguyen ;
Hau Van Nguyen ;
Bui, Khang Hoang ;
Seo, Tae Seok .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 301