End-to-End Quality Assurance of Stereotactic Radiation Therapy Using an Anthropomorphic Head Phantom

被引:5
作者
Alexander, Km [1 ]
Dekker, Kh [1 ]
Olding, T. [1 ,2 ,3 ]
Schreiner, Lj [2 ,3 ]
机构
[1] Kingston Hlth Sci Ctr, Canc Ctr Southeastern Ontario, Kingston, ON K7L 5P9, Canada
[2] Queens Univ, Dept Phys, Kingston, ON K7L 3N6, Canada
[3] Queens Univ, Dept Oncol, Kingston, ON K7L 3N6, Canada
来源
11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE | 2022年 / 2167卷
关键词
D O I
10.1088/1742-6596/2167/1/012022
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In the clinic, routine quality assurance tests ensure the proper functioning of each individual aspect of a radiation therapy treatment delivery. However, these tests may not guarantee an accurate treatment delivery. In this work, we present the design and application of a head phantom (using 3D printing technology) developed for end-to-end quality assurance of a stereotactic radiation therapy treatment for brain metastases, coupled with inserts for ion chamber, and film and gel dosimeters. The head phantom was subjected to the entire clinical workflow, with each stage of the process being performed by the appropriate clinical personnel to ensure that this quality assurance test mimics the clinical scenario.
引用
收藏
页数:6
相关论文
共 12 条
[1]   Streamlined open-source gel dosimetry analysis in 3D slicer [J].
Alexander, K. M. ;
Pinter, C. ;
Fichtinger, G. ;
Olding, T. ;
Schreiner, L. J. .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (04)
[2]   Development of 3D Slicer based film dosimetry analysis [J].
Alexander, K. M. ;
Robinson, A. ;
Pinter, C. ;
Fichtinger, G. ;
Schreiner, L. J. .
9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
[3]   An apparent threshold dose response in ferrous xylenol-orange gel dosimeters when scanned with a yellow light source [J].
Babic, Steven ;
Battista, Jerry ;
Jordan, Kevin .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (06) :1637-1650
[4]   Radiochromic leuco dye micelle hydrogels: II. Low diffusion rate leuco crystal violet gel [J].
Babic, Steven ;
Battista, Jerry ;
Jordan, Kevin .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (22) :6791-6808
[5]   Polymer gel dosimetry [J].
Baldock, C. ;
De Deene, Y. ;
Doran, S. ;
Ibbott, G. ;
Jirasek, A. ;
Lepage, M. ;
McAuley, K. B. ;
Oldham, M. ;
Schreiner, L. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (05) :R1-R63
[6]   Stray light in cone beam optical computed tomography: III. Evaluation of a redesigned large-volume commercial scanner based on a convergent light source [J].
Dekker, Kurtis H. ;
Hazarika, Rubin ;
Jordan, Kevin J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (21)
[7]   Adjuvant treatment of brain metastases [J].
Lohr, F ;
Pirzkall, A ;
Hof, H ;
Fleckenstein, K ;
Debus, J .
SEMINARS IN SURGICAL ONCOLOGY, 2001, 20 (01) :50-56
[8]   Volumetric Radiosurgery for 1 to 10 Brain Metastases: A Multicenter, Single-Arm, Phase 2 Study [J].
Nichol, Alan ;
Ma, Roy ;
Hsu, Fred ;
Gondara, Lovedeep ;
Carolan, Hannah ;
Olson, Robert ;
Schellenberg, Devin ;
Germain, Francois ;
Cheung, Arthur ;
Peacock, Michael ;
Bergman, Alanah ;
Vollans, Emily ;
Vellani, Rosemin ;
McKenzie, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 94 (02) :312-321
[9]   Cone-beam optical computed tomography for gel dosimetry II: imaging protocols [J].
Olding, Tim ;
Schreiner, L. John .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (05) :1259-1279
[10]   End to end QA in image guided and adaptive radiation therapy [J].
Schreiner, L. J. .
10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305